Additional Resources: Product Page 3D Model date 03/25/2021 page 1 of 7 SERIES: PSK-60 DESCRIPTION: INTERNAL AC-DC POWER SUPPLY FEATURES universal input voltage range (85~264 VAC) IEC/EN/UL 62368 certified meets CISPR32/EN 55032 Class B without external components 4,000 VAC isolation rating short-circuit, over-current, over-voltage protections output output output ripple efficiency MODEL voltage current power and noise max max max typ (Vdc) (A) (W) (mVp-p) (%) PSK-60-5 5 10.0 50 120 84 PSK-60-12 12 5.0 60 120 87 PSK-60-15 15 4.0 60 120 88 PSK-60-24 24 2.5 60 120 89 PSK-60-48 48 1.25 60 120 90 PART NUMBER KEY PSK-60 - XX- X Base Number Output Voltage Mounting Style blank = board mount T = chassis mount DIN = DIN-rail mount cui.comAdditional Resources: Product Page 3D Model CUI Inc SERIES: PSK-60 DESCRIPTION: AC-DC POWER SUPPLY date 03/25/2021 page 2 of 7 INPUT parameter conditions/description min typ max units ac input 85 264 Vac voltage dc input 100 370 Vdc frequency 47 63 Hz at 115 Vac 1.8 current A at 230 Vac 1.0 at 115 Vac 45 inrush current A at 230 Vac 90 no load power consumption at 230 Vac 0.5 W OUTPUT parameter conditions/description min typ max units 5 Vdc output 20,000 12 Vdc output 4,000 capacitive load 15 Vdc output 3,000 F 24 Vdc output 1,800 48 Vdc output 470 initial set point accuracy at full load 2 % line regulation rated load 0.5 % load regulation 0%~100% load 1.0 % at 115 Vac 8 hold-up time ms at 230 Vac 65 temperature coefficient 0.02 %/C PROTECTIONS parameter conditions/description min typ max units 5 Vdc output, clamp or hiccup 9 12 Vdc output, clamp or hiccup 16 over voltage protection 15 Vdc output, clamp or hiccup 25 Vdc 24 Vdc output, clamp or hiccup 35 48 Vdc output, clamp or hiccup 60 over current protection auto recovery 110 % short circuit protection hiccup, continuous, auto recovery SAFETY & COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output 4,000 Vac safety approvals UL/cUL, EN, IEC 62368 safety class Class II EMI/EMC CISPR 32/EN 55032 Class B ESD IEC/EN 61000-4-2 Contact 6KV/Air 8KV, perf. Criteria B radiated immunity IEC/EN 61000-4-3 10 V/m, perf. Criteria A EFT/burst IEC/EN 61000-4-4 4KV, perf. Criteria B IEC/EN 61000-4-5 line to line 2KV/line to ground 4KV, perf. Criteria B (see recomended EMC circuit) surge IEC/EN 61000-4-5 1KV line to line, perf. Criteria B conducted immunity IEC/EN 61000-4-6 10 Vr.m.s, perf. Criteria A voltage dips and interruption IEC/EN 61000-4-11 0%, 70%, perf. Criterial B MTBF per MIL-HDBK-217F at 25 C 300,000 hours RoHS yes cui.com