Additional Resources: Product Page date 11/23/2021 page 1 of 5 SERIES: SWH15-E DESCRIPTION: AC-DC POWER SUPPLY FEATURES up to 15 W continuous power universal input voltage range no load power consumption < 0.1 W over current and short circuit protections IEC 61558 & EN 60335 compliant custom designs available input input output output output ripple efficiency no load power MODEL voltage frequency voltage current power and level consumption 1 noise range range nom max max max average2 10% max (Vac) (Hz) (Vdc) (A) (W) (mVp-p) (%) (%) (W) SWH15-5-E 90 ~ 264 47 ~ 63 5 2.0 10.0 200 78.7 65.0 0.1 SWH15-5B-E 90 ~ 264 47 ~ 63 5 3.0 15.0 200 81.4 65.0 0.1 SWH15-9-E 90 ~ 264 47 ~ 63 9 1.5 13.5 200 83.6 65.0 0.1 SWH15-12-E 90 ~ 264 47 ~ 63 12 1.0 12.0 200 83.0 65.0 0.1 SWH15-24-E 90 ~ 264 47 ~ 63 24 0.6 14.4 200 83.9 65.0 0.1 Notes: 1. At full load, nominal AC input voltage, 25C, 20 MHz bandwidth oscilloscope, output terminated with 0.1 F and 10 F capacitors to ground. 2. Average efficiency is measured at 25%, 50%, 75%, and 100% load at 115 Vac & 230 Vac input. PART NUMBER KEY SWH15 - XX - EX- XXX - CXX Reserved for Custom Base Number Configurations Output Voltage AC Input Type: Case Color: DC Plug Type: Europe B = black XXX = See output plug options W = white on page 4 for more details cui.comAdditional Resources: Product Page CUI Inc SERIES: SWH15-E DESCRIPTION: AC-DC POWER SUPPLY date 11/23/2021 page 2 of 5 INPUT parameter conditions/description min typ max units voltage 90 264 Vac frequency 47 63 Hz current 0.5 A leakage current at 240 Vac, 50 Hz 0.25 mA no load power consumption 0.1 W OUTPUT parameter conditions/description min typ max units line regulation 1 % load regulation +7/-5 % start-up time at 100 and 240 Vac, full load 3 s at 115 Vac/60 Hz 1 ms hold-up time at 230 Vac/50 Hz 3 ms PROTECTIONS parameter conditions/description min typ max units over current protection auto recovery, hiccup short circuit protection auto recovery SAFETY & COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output at 10 mA for 1 minute 3,000 Vac IEC: 61558, 61558-2-16 safety approvals EN 60335 EMI/EMC EN 55014-1, EN 55014-2 MTBF at full load, 25C 50,000 hours RoHS yes ENVIRONMENTAL parameter conditions/description min typ max units operating temperature 0 40 C storage temperature -20 70 C operating humidity 10 95 % storage humidity 5 95 % cui.com