Additional Resources: Product Page 3D Model date 11/27/2020 page 1 of 5 SERIES: SWI10B-E DESCRIPTION: AC-DC POWER SUPPLY FEATURES up to 12 W continuous power DoE Level VI efficiency universal input voltage range ultra-compact case no load power consumption < 0.075 W over voltage, over current, and short circuit protections certified to IEC 62368-1 standards CE safety approval Class II construction black and white case options available input input output output output ripple efficiency no load power MODEL voltage frequency voltage current power and level consumption 1 noise range range nom max max max average2 10% typ (Vac) (Hz) (Vdc) (A) (W) (mVp-p) (%) (%) (W) SWI10B-5-E 90 ~ 264 47 ~ 63 5 2 10 300 79.9 76.1 0.06 SWI10B-12-E 90 ~ 264 47 ~ 63 12 1 12 180 84.0 79.3 0.06 Notes: 1. At full load, nominal AC input voltage, 25C, 20 MHz bandwidth oscilloscope, output terminated with 0.1 F and 10 F capacitors to ground. 2. Average efficiency is measured at 25%, 50%, 75%, and 100% load. PART NUMBER KEY SWI10B - XX - EX - XXX - CXX Reserved for Custom Base Number Configurations Output Voltage AC Input Type: Case color: DC Plug Type: European B - Black XXX = See output plug options W - White on page 4 for more details cui.comAdditional Resources: Product Page 3D Model CUI Inc SERIES: SWI10B-E DESCRIPTION: AC-DC POWER SUPPLY date 11/27/2020 page 2 of 5 INPUT parameter conditions/description min typ max units voltage 90 264 Vac frequency 47 63 Hz current at nominal input voltage 0.5 A leakage current at nominal input voltage & frequency 0.25 mA no load power consumption at 115/230 Vac 0.075 W OUTPUT parameter conditions/description min typ max units regulation 5 % start-up time at nominal input voltage 3 s rise time at nominal input voltage 100 ms hold up time 5 ms PROTECTIONS parameter conditions/description min typ max units 5 Vdc output model 10 Vdc over voltage protection 12 Vdc output model 18 Vdc output shut down, auto recovery over current protection 5 Vdc output model 3.0 A 12 Vdc output model 1.8 A short circuit protection yes SAFETY & COMPLIANCE parameter conditions/description min typ max units 3,000 Vac isolation voltage input to output at 10 mA for 1 minute 4,242 Vdc safety approvals CE EMI/EMC EN55032:2015, EN55035:2017 as per Telcordia SR-332 (Issue 2), at 115/230 Vac, MTBF 50,000 hours full load, 0C~40C RoHS yes ENVIRONMENTAL parameter conditions/description min typ max units operating temperature 0 40 C storage temperature -20 60 C operating humidity non-condensing 20 85 % storage humidity non-condensing 5 95 % cui.com