Additional Resources: Product Page date 01/10/2017 page 1 of 4 SERIES: VDRS-100 DESCRIPTION: AC-DC DIN RAIL FEATURES up to 96 W continuous power DIN Rail power supplies universal input (88~264 Vac / 124~370 Vdc) single output from 12~48 Vdc over voltage, over load, over temperature, and short circuit protections UL 1310, UL 508, and TUV safety approvals long life electrolytic capacitors efficiency up to 88% output output output ripple efficiency MODEL 1 voltage current power and noise max max max (Vdc) (A) (W) (mVp-p) (%) VDRS-100-12 12 7.5 90 180 87 VDRS-100-15 15 6.4 96 180 87 VDRS-100-24 24 4 96 180 88 VDRS-100-48 48 2 96 250 87 Note: 1. At full load, 230 Vac input, measured at 20MHz bandwidth with a 47 F and 0.1 F parallel capacitors on the output. 2. All specifications are measured at Ta=25C, 230 Vac input voltage, and rated output load unless otherwise specified. PART NUMBER KEY VDRS - 100 - XX Base Number Output Voltage cui.com DISCONTINUEDAdditional Resources: Product Page date 01/10/2017 page 2 of 4 CUI Inc SERIES: VDRS-100 DESCRIPTION: AC-DC DIN RAIL INPUT parameter conditions/description min typ max units 88 264 Vac voltage 124 370 Vdc frequency 47 63 Hz 115 Vac 1.1 A current 230 Vac 0.55 A 115 Vac, cold start 30 A inrush current 230 Vac 60 A at 115 Vac, full load 0.98 power factor at 230 Vac, full load 0.92 OUTPUT parameter conditions/description min typ max units line regulation 1 % load regulation 2 % temperature coefficient (0 ~ 50C) 0.03 %/C at 115 Vac, cold start 16 ms hold-up time at 230 Vac, cold start 32 ms adjustability adjustable with built-in trim pot 10 % PROTECTIONS parameter conditions/description min typ max units over voltage protection latch-off mode 115 150 % constant current limiting, automatically recovers over load protection 102 % after fault condition is removed short circuit protection output shut down and auto restart SAFETY & COMPLIANCE parameter conditions/description min typ max units input to output for 1 minute 3,000 Vac isolation voltage input to case for 1 minute 1,500 Vac input to output, input to case, isolation resistance 100 M output to case, 500 Vdc UL 508, TUV EN 60950-1, safety approvals 1 UL 1310 NEC class 2 compliant EN 55022 : 2006(Class B), EN 61204-3: 2000, EN 61000-6-3: 2007, EN 61000-3-2,3 :2006, 2 EMI/EMC EN 55024, EN 61204-3: 2000, EN 61000-6-1: 2007 (EN 61000-4-2,3,4,5,6,8,11) leakage current at 230 Vac 1 mA RoHS 2011/65/EU Note: 1. UL 1310 only for 24 & 48 Vdc output models. 2. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives. ENVIRONMENTAL parameter conditions/description min typ max units operating temperature see derating curves -20 70 C storage temperature -40 85 C operating humidity non-condensing 20 90 % storage humidity 10 95 % vibration (10 ~ 500 Hz, 1 hour per axis, 3 hours total) 5 Grms cui.com DISCONTINUED