Thermal Overcurrent Circuit Breaker 1410-F1... Description Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (filament bulb for low voltages) illuminates to give a clear signal of the tripped status of the mechanism and thereby the cause of power interruption, suffix -B. Alternatively the illumination can be conventionally wired to indicate the ON status of the device, suffix -E. Returning the rocker switch through the OFF position and back ON will reset the mechanism and restore the supply. Largely temperature-insensitive. Complies with CBE standard EN 60934 (IEC 60934). 1 Typical applications 1410-F1.. Motors, transformers, solenoids, PCBs, hand-held machines, appliances, instrumentation. Technical data For further details please see: www.e-t-a.de/ti e Ordering information Voltage rating AC 240 V DC 28 V (DC 50 V upon request) (UL: AC 250 V DC 48 ) Type No. Current rating range 0.63...10 A 1410 snap-in panel mounting type Mounting Typical life F snap-in panel mounting circuit 1-3 30,000 operations for I 6.3 A AC/DC N Size of frame 10,000 operations for I > 6.3 A AC N 1 to fit mounting cut-out 28 x 12.7 mm (1.1 x .5 in) 3,000 operations for I > 6.3 A DC N Number of poles protection circuit 1-2 500 break operations at 2 x I N 1 single pole, thermally protected Ambient temperature -20...+70 C (-4...+158 F) Accessories Insulation co-ordination rated impulse pollution 0 without accessories (IEC 60664 and 60664 A) withstand voltage degree Terminal design 2.5 kV 2 P1 blade terminals 2.8-0.8 (QC .110/2x.110) silver-plated reinforced insulation in operating area Characteristic curve F1 fast acting Dielectric strength Actuator style (IEC 60664 and 60664A) test voltage W rocker, rounded profile operating area AC 3,000 V Actuator colour Insulation resistance > 100 M (DC 500 V) 14 red translucent Interrupting capacity I 0.63...2 A 12 x I cn N Actuator markings 2.5...8 A 8 x I , AC max. 50 A N Q I and O 10 A 6 x I N Trip/ON illumination (optional) 3.15...10 A 10 x I , DC N B illuminated when tripped E illuminated when ON Interrupting capacity 0.63...10 A 2,000 A AC 250 V Illumination voltage range (UL 1077) 0.63...8 A 200 A DC 50 V (optional) 0.63...5 A 200 A DC 60 V 2 20-28 V marked 24 V 35 mA Degree of protection operating area IP30 3 90-140 V marked 115 V < 1 mA (IEC 60529/DIN 40050) terminal area IP00 4 185-275 V marked 230 V < 1 mA Vibration 8 g (57-500 Hz) 0.61 mm (10-57 Hz), Current ratings to IEC 60068-2-6, test Fc, 0.63...10 A 10 frequency cycles/axis 1410 - F 1 1 0 - P1 F1 - W 14 Q E 3 - 2 A ordering example Shock 20 g (11 ms) to IEC 60068-2-27, test Ea Please be informed that we have minimum ordering quantities to be observed. Corrosion 48 hours at 5 % salt mist, to IEC 60068-2-11, test Ka Humidity 96 hours at 95 % RH Standard current ratings and typical internal resistance values to IEC 60068-2-78, test Cab Mass approx. 9 g Current Internal Current Internal rating (A) resistance () rating (A) resistance () 0.63 1.8 4 < 0.1 Approvals 1 1.3 5 < 0.1 1.5 < 1 6.3 < 0.1 Authority Standard Rated voltage Current ratings 2 < 1 8 < 0.1 UL UL 1077 AC 250 V 0.63 A10 A 2.5 < 0.15 10 < 0.1 DC 60 V 0.63 A5 A DC 50 V 5.5 A8 A 3.15 < 0.12 CSA C22.2 No 235 AC 125 V 0,63 A8 A DC 48 V 0,63 A8 A 1942 www.e-t-a.de 1+0,2 R 0.2 +.008 R .008 20 Thermal Overcurrent Circuit Breaker 1410-F1... Dimensions Internal connection diagrams 1410-F...-....-....B. 1410-F...-....-....B. 1410-F...-....-....E. 16 .630 13.5 1 17 .531 .039 6 .670 .236 5 32 13 2 14 2 1.26 .197 ON OFF line line 27.6 1.5 lamp current: 1 1.09 .059 24 V = 35 mA 115 V < 1 mA 230 V < 1 mA Typical time/current characteristics at +23 C/+73.4 F 5.1 1 7.5 1 10000 blade terminals .201 .295 .039 .039 12 8.8 DIN 46244-C .472 .346 (QC 2x.110) 23.5 12 .925 .472 1000 2.1 blade terminal .083 32.3 DIN 46244-A2.8-0.8 1.27 (QC .110) illuminated trip indication 100 21.2 10 .835 1410-F...-....-....E. 1 16 .630 0.1 13.5 1 .531 .039 6 17 0.01 12 46 8102040 .236 .670 5 32 times rated current .197 ON OFF 1.26 1.5 27.6 .059 1.09 Installation drawing When installing the circuit breaker apply pressure on bezel only operating area 2.8 5.1 11.5 1 .110 .201 .453 .039 7.5 1 8.8 blade terminals 12 .039 .295 .346 DIN 46244-C .472 12 (QC 2x.110) 23.5 .472 2.1 .925 blade terminal .083 32.3 DIN 46244-A2.8-0.8 1.27 (QC .110) illuminated ON indication 21.2 .835 panel cut-out 0.8 3 10 10 10 10 +0.2 28 mounting area .031 .118 .394 .394 .394 .394 +.008 1.10 mm This is a metric design and millimeter dimensions take precedence ( ) inch sharp edged All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 2 www.e-t-a.de 1942 2 .079 9.5 3 9.5 3 .118 .374 .374 .118 6.5 10.4 10.4 6.5 .256 .256 .409 .409 +0.3 12.7 +.012 .500 21.2 21.2 .835 .835 23.2 3 23.2 3 .913 .118 .913 .118 9 9 .354 .354 Trip time in seconds 32 10 1.26 .394