Thermal Overcurrent Circuit Breaker 1410-F1... Description Miniaturised single pole rocker switch/thermal circuit breaker combining ON/OFF switching and extremely fast overload performance in a single component (S-type TO CBE to EN 60934/IEC 934). Under overload conditions an internal neon (filament bulb for low voltages) illuminates to give a clear signal of the tripped status of the mechanism and thereby the cause of power interruption, suffix -B. Alternatively the illumination can be conventionally wired to indicate the ON status of the device, suffix -E. Returning the rocker switch through the OFF position and back ON will reset 1 the mechanism and restore the supply. Largely temperature-insensitive. Complies with CBE standard EN 60934 (IEC 60934). Typical applications Motors, transformers, solenoids, PCBs, hand-held machines, appliances, 1410-F1.. instrumentation. Ordering information Technical data Type No. Voltage rating AC 240 V DC 28 V (DC 50 V upon request) 1410 snap-in panel mounting type (UL: AC 250 V DC 48 ) Mounting Current rating range 0.63...10 A F snap-in panel mounting Typical life Size of frame circuit 1-3 30,000 operations for I 6.3 A AC/DC 1 to fit mounting cut-out 28 x 12.7 mm (1.1 x .5 in) N 10,000 operations for I > 6.3 A AC Number of poles N 3,000 operations for I > 6.3 A DC 1 single pole, thermally protected N protection circuit 1-2 300 break operations at 2 x I Accessories N 0 without accessories Ambient temperature -40...+70 C (-40...+158 F) Terminal design Insulation co-ordination rated impulse pollution P1 blade terminals 2.8-0.8 (QC .110/2x.110)silver-plated (IEC 60664 and 60664 A) withstand voltage degree Characteristic curve 2.5 kV 2 F1 fast acting reinforced insulation in operating area Actuator style Dielectric strength W rocker, rounded profile (IEC 60664 and 60664A) test voltage Actuator colour operating area AC 3,000 V 14 red translucent Actuator markings Insulation resistance > 100 M (DC 500 V) Q I and O Interrupting capacity I 0.63...2 A 12 x I cn N Trip/ON illumination (optional) 2.5...8 A 8 x I , AC max. 50 A N B illuminated when tripped 10 A 6 x I N E illuminated when ON 3.15...10 A 10 x I , DC N Illumination voltage range Interrupting capacity 0.63...10 A 2,000 A AC 250 V (optional) (UL 1077) 0.63...8 A 200 A DC 50 V 2 20-28V marked 24V 35mA 0.63...5 A 200 A DC 60 V 3 90-140V marked 115V <1mA 4 185-275V marked 230V <1mA Degree of protection operating area IP30 Current ratings (IEC 60529/DIN 40050) terminal area IP00 0.63...10 A Vibration 8 g (57-500 Hz) 0.61 mm (10-57 Hz), to IEC 60068-2-6, test Fc, 1410 - F 1 1 0 -P1 F1 - W 14 Q E 3 - 2 A ordering example 10 frequency cycles/axis Shock 20 g (11 ms) The exact part number required can be built up from the table of choices shown to IEC 60068-2-27, test Ea above. Ordering references for optional features should be omitted if not required. Corrosion 48 hours at 5 % salt mist, to IEC 60068-2-11, test Ka Humidity 96 hours at 95 % RH to IEC 60068-2-3, test Ca Mass approx. 9 g Standard current ratings and typical internal resistance values Approvals Current Internal Current Internal Authority Voltage ratings Current ratings rating (A) resistance ( ) rating (A) resistance ( ) UL, CSA AC 250 V 0.63...10 A 0.63 1.8 3.15 < 0.12 DC 50 V 0.63...8 A UL DC 60 V 0.63...5 A 0.8 1.7 4 < 0.1 11.3 5< 0.1 1.5 < 1 6.3 < 0.1 1.8 < 1 8 < 0.1 2 < 1 10 < 0.1 2.5 < 0.15 05/06 www.e-t-a.com+0.2 R 0.2 +.008 R .008 20 Thermal Overcurrent Circuit Breaker 1410-F1... Dimensions Internal connection diagram 1410-F...-....-....B. 1410-F...-....-....B. 1410-F...-....-....E. 16 .630 1 13.5 1 17 .531 .039 6 .670 .236 32 5 13 2 14 2 1.26 .197 ON OFF line line 27.6 1.5 lamp current: 1.09 .059 24 V = 35 mA 115 V < 1 mA 230 V < 1 mA Typical time/current characteristics at +23C/+73.4F 1 5.1 7.5 1 10000 blade terminals .201 .295 .039 .039 12 8.8 DIN 46244-C .472 .346 (QC 2x.110) 23.5 12 1000 2.1 .925 .472 blade terminal .083 32.3 DIN 46244-A2.8-0.8 (QC .110) 1.27 illuminated trip indication 100 10 21.2 .835 1410-F...-....-....E. 1 16 .630 0.1 13.5 1 .531 .039 6 17 0.01 12 46810 20 40 .236 .670 5 32 times rated current .197 OFF ON 1.26 1.5 27.6 .059 1.09 Installation drawing operating area 2.8 5.1 11.5 1 .110 .201 .453 .039 7.5 1 8.8 blade terminals 12 .039 .295 .346 DIN 46244-C .472 12 (QC 2x.110) 23.5 .472 2.1 .925 blade terminal .083 32.3 DIN 46244-A2.8-0.8 1.27 (QC .110) illuminated ON indication 21.2 10 10 10 10 .835 mounting area .394 .394 .394 .394 panel cut-out 0.8 3 +0.2 28 .031 .118 +.008 1.10 mm This is a metric design and millimeter dimensions take precedence ( ) inch sharp edged All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. www.e-t-a.com 05/06 2 .079 3 9.5 9.5 3 .374 .118 .374 .118 6.5 10.4 6.5 10.4 .256 .256 .409 .409 +0.3 12.7 +.012 .500 21.2 21.2 .835 .835 23.2 3 23.2 3 .913 .118 .118 .913 9 9 .354 .354 Trip time in seconds 32 10 1.26 .394