Module 17plus Description Module 17plus is a mounting and power distribution system for use with the following plug-in type devices: l 2210-S, 3600 and 3900 circuit breakers l ESS30-S, ESX10 and ESX10-S electronic circuit breakers and protectors l E-1048-S7... solid state remote power controller Each module accommodates two breakers with an individual housing width of 12.5 mm and fits onto all industry standard mounting rails. The two-way modules are mounted side-by-side to provide as many ways as required with a terminal block fitted at each end for connection of signalling circuits. Electrical connections are by means of screwless spring-loaded terminals. Fitting a busbar on the terminal side of the 17plus modules provides power distribution onto the individual ways with a common line entry. When plugging in multipole circuit breakers, the busbar cannot be used. In this case each pole has to be individually con- Fitted with ESS30-S: nected. All internal wirings for the ground potential and the group signal The reference potential for the ESS30-S.. (Gnd pin 11) is also looped are established by the side-by-side mounting of the individual modules through and connected to the terminal elements at the sides. All internal (centre pieces, terminal blocks). The suitable circuit breakers or SSRPCs wirings for the ground potential and the group signal are established have integral signal contacts (break and make contacts). Depending on by the side-by-side mounting of the individual modules (centre pieces, the application they can be used for single or group signalling. When terminal blocks). The ESS30-S003 features an integral auxiliary contact using multipole breakers, auxiliary contacts are required in each pole (change-over). The contact SC-SO is used for the group fault indica- so as not to interrupt the current loop of the group signalling by missing tion. For this type of signalling, all contacts in the Modules 17plus are auxiliary contacts. connected in series and are connected via two terminals (13, 14) to the terminals blocks on either side. It is possible with a test probe to contact Fitted with 2210-S: the series connection in each module and detect possible interruptions. The integral auxiliary contacts of thermalmagnetic circuit breaker type 2210-S (make and break) can be used for single or group signalling, Fitted with ESX10/ESX10-S: depending on the application. For group fault signalling all required The reference potential for the ESX10 (Gnd pin 11) is also looped terminals (make contacts, they open in the event of a failure) within the through and connected to the terminal elements at the sides. The inte- Module 17plus are connected in series. Group signalling is realised via gral signal output SF of the ESX10-124/-S124 can be tapped at terminal the terminals on the side (13, 14). Single signalling requires connection 12 of the relevant channel (single signalling). The inverted status output of the break contacts (they close in the event of a failure). In this case SF can also be tapped at terminal 12 of the corresponding channel. The one side of the contacts in the modules is connected in parallel (pin 11). reset input RE can be connected via terminal 13 or 14 (ESX10-124/ The second contact side is accessible per module way and can be con- S124/-127/-S127) or terminal 12 (ESX10-125/-S125). The integral control nected via terminal (pin 12). Both types of signalling are available at the input IN+ of type ESX10-115/-S115 is fed in via terminal 12. Depending same time, if the circuit breaker type used has auxiliary contacts (please on the option, a potential-free auxiliary contact is also available (ESX10- note when ordering). 103/-115/-125/-S103/-S115/-S125). Fitted with 3600/3900: Fitted with E-1048-S7xx: The integral auxiliary contacts of thermalmagnetic circuit breaker types The reference potential (Gnd pin 11) is also looped through and 3600/3900 (make and break) can be used for single or group signalling, connected to the terminal elements at the sides. Actuation of the depending on the application. For group fault signalling all required SSRPC (IN+), referenced to GND), is via the separate terminal 12 per terminals (make contacts, they open in the event of a failure) within the way beside the LOAD terminal. The SSRPC has an integral auxiliary Module 17plus are connected in series. Group signalling is realised via contact (break contact) used for group fault signalling. For this type the terminals on the side (13, 14). Single signalling requires connection of signalling, all contacts in the Modules 17plus are connected in of the break contacts (they close in the event of a failure). In this case series and are connected via two terminals (13, 14) to the terminals one side of the contacts in the modules is connected in parallel (pin blocks on either side. It is possible with a test probe to contact the 11). The second contact side is accessible per module way and can be series connection in each module and detect possible interruptions. connected via terminal (pin 12). Both types of signalling are available at All internal wirings for the ground potential and the group signal are the same time. established by the side-by-side mounting of the individual modules. 6 1941 www.e-t-a.de 1Modul 17 plus GERMANY Module 17plus 2210-S/3600/3900 Module 17plus Technical data Ordering information Connection Spring-loaded terminals for rigid wires or 17PLUS-Q02-00 Module 17plus, centre piece flexible cables with unisolated wire end two-way one each left- and right-side terminal ferrules or without wire end ferrules. 17PLUS-QA0-LR block for supply feed from the side by means Please use appropriate screw driver size (SD) of screw terminal for removing the spring loaded terminals. For technical data of: cross section of screw stripped cable connecting cable driver length l 2210-S, 3600, 3900 Line feed 2 l ESS30-S, ESX10, ESX10-S 1.5-10 mm 3 (1.0 x 5.5) 12 mm (1.1/ 1.2) l E-1048-S7 Load output 2 0.25-4 mm 1 (0.6 x 3.5) 12 mm (2.1/2.2) Please use the search function of www.e-t-a.de by entering the 2 Signalisation 0.25-2.5 mm 1 (0.6 x 3.5) 10 mm product group (e.g. 2210-S) to view individual data sheets. terminals (11, 13, 14) Signalisation 2 Installation example (with type 2210) 0.25-1.5 mm 0 (0.4 x 2.5) 9 mm terminal (12.1/12.2) Diameter of 2 mm test socket Voltage rating AC 250 V 3 AC 433 V DC 65 V (without circuit breaker) with 2210-S: AC 250 V 3 AC 433 V DC 65 V with 3600/3900: AC 240 V (50/60 Hz) DC 65 V with ESX10/ESX10-S: 18 V...32 V DC with E-1048-S7..: 18 V...36 V DC with ESS30: 18 V...30 V DC 6 4 Current rating (without circuit breaker) Line feed (1.1/1.2) 50 A Load output (2.1/2.2) 25 A Signalisation Feed (11) 5 (ground with electronic components) 10 A Single output (12.1/12.2) 1 A (with ESX10: 0,5 A) 3 Group signal (13-14) 1 A (with ESX10: 0,5 A) Caution: When several devices are mounted together, each should 3 carry only max. 80 % ( I 16 A) or max. 65 % (I > 16 A) of its rating. N N Internal resistances (without circuit breaker) 2 Line/load (1.1-2.1) 5 m 1 Signalisation 9 m (+ 2 m per additional module) Group signal (13-14) 8 m (+ 5 m per additional module) Installation: Vibration 5 g (57-500 Hz) 0,38 mm (10-57 Hz) 1 Clip modules onto DIN rails. to IEC 60068-2-6, test Fc, 2 Push modules together (side-by-side). 10 frequency cycles/axis 3 Snap on right-side and left-side terminal blocks. Shock 25 g (11 ms) 4 Cut busbar to required length and fit on supply side of the modules. to IEC 60068-2-27, test Ea 5 Connect line feed with spring-loaded terminals. 11 ms half sine 6 Plug in circuit breakers. Corrosion 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka Humidity 240 hours at 95 % RH 1 Line 1 Line to IEC 60068-2-78, test Cab Dielectric strength SD 3 1 Line 1 Line between main circuits (without busbar): 1 500 V 6 main circuit to auxiliary circuit: 1 500 V SD 1 11 11 between auxiliary circuits: 1 500 V 11 11 (without circuit breaker) Mass Module 17plus (centre piece) approx. 85 g 13 14 SD 1 terminal blocks (pair) approx. 30 g 2 2 12 12 13 14 Approvals Authority Standard Rated voltage Current ratings 2 2 SD 0 12 12 AC 250 V 25 A per channel UL UL 60950 Connection and disconnection of cables with screw driver DC 80 V 25 A per channel 2 www.e-t-a.de 1941 LOAD LOAD LOAD LOAD 12 2 12 2 12 2 12 2 1 LINE 1 LINE 1 LINE 1 LINE 11 11 13 14