Thermal-Magnetic Circuit Breaker 2215-L.../G... Description Miniaturised single pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934). Two designs provide the option of either printed circuit board or threadneck panel mounting. A separate shunt tap terminal and auxiliary contacts are available. Fast acting, medium or long delay characteristics can be specified for both models. Suitable for use in distribution rails see section Power Distribution Systems. Complies with CBE standard EN 60934 (IEC 60935). Typical applications 1 2215-L1.. 2215-G1... Control equipment, communications systems, instrumentation. Suitable for mounting on Euro cards. Technical data Ordering information 2215-G1 For further details please see: www.e-t-a.de/ti e Type No. Voltage rating AC 250 V (50/60 Hz) DC 50 V 2215 single pole thermal-magnetic circuit breaker (UL: AC 250 V DC 75 V) Mounting Current rating range 0.05...10 A G1 threadneck panel mounting (higher current ratings to special order) Number of poles Auxiliary circuit 1 A, AC 250 V / DC 28 V 1 1-pole protected Mounting hardware Typical life 10,000 operations at 1 x I N 1 2 hex nuts 1/4-40 UNS-2A, serrated washer, Ambient temperature -30...+60 C (-22...+140 F) location pin (-G1 only) Insulation co-ordination rated impulse pollution Terminal design (main contacts) (IEC 60664 and 60664 A) withstand voltage degree P1 blade terminals 6.3-0.8, without shunt terminal 2.5 kV 2 Characteristic curve reinforced insulation in operating area F1 fast acting:1.01-1.4xI magn.2-4xI DC (DC only) N N M1 standard delay: therm. 1.01-1.4xI Dielectric strength N magn. 4.5-10.5xI DC magn. 3.5-8xI AC IEC 60664 and 60664A) test voltage N N T1 delayed: therm. 1.01-1.4xI DC operating area AC 3,000 V N magn. 8-17xI DC, 6-13xI AC main/aux. circuit AC 1,500 V N N Auxiliary contacts Insulation resistance > 100 M (DC 500 V) S0 without auxiliary contact Interrupting capacity I 300 A cn S11 with auxiliary contact (change over) blade terminals 6.3x0.8 (QC .250) Interrupting capacity Current ratings (UL 1077) I U N N 0.05...10 A 0.05 A AC 250 V 200 A 0.1...6 A AC 250 V 1,000 A 2215 - G1 1 1 - P1 F1 - S11 - 0.5 A ordering example 8...10 A AC 250 V 2,000 A 0.05...10 A DC 50 V 1,000 A Degree of protection operating area IP30 (IEC 60529/DIN 40050) terminal area IP00 Ordering information 2215-L1 Vibration curve F1: 6 g (57-500 Hz), 0.46 mm (10-57 Hz) Type No. curves M1, T1: 8 g (57-500 Hz), 0.61 mm (10-57 Hz) 2215 single pole thermal-magnetic circuit breaker to IEC 60068-2-6, test Fc Mounting 10 frequency cycles/axis L1 PCB mounting Number of poles Shock 1 1-pole protected curves F1, M1, T1: 30 g (11 ms), directions 1, 2, 3, 4, 5, Mounting hardware curve F1: 10 g (11 ms), direction 6 0 without accessories curves M1, T1: 15 g (11 ms), direction 6 Terminal design (main contacts) to IEC 60068-2-27, test Ea L1 solder pins, without shunt terminal Corrosion 96 hours at 5 % salt mist Characteristic curve to IEC 60068-2-11, test Ka F1 fast acting:1.01-1.4xI magn.2-4xI DC (DC only) N N Humidity 240 hours at 95 % RH M1 standard delay: therm. 1.01-1.4xI N to IEC 60068-2-78, test Cab magn. 4.5-10.5xI DC magn. 3.5-8xI AC N N Auxiliary contacts - terminal design Mass approx. 25 g S0 without auxiliary contact S12 with auxiliary contact (change over) Approvals solder pins Current ratings 0.05...10 A Authority Standard Rated voltage Current ratings 2215 - L1 1 0 - L1 F1 - S12 - 0.5 A ordering example UL UL 1077 AC 250 V 0.05 A10 A DC 75 V 0.05 A10 A (20 A) Please be informed that we have minimum ordering quantities to be CSA C22.2 No. AC 250 V 0.05 A10 A observed. DC 75 V 0.05 A10 A (20 A) 235 1942 www.e-t-a.de 125 10 Thermal-Magnetic Circuit Breaker 2215-L.../G... Thermal-Magnetic Circuit Breaker 2215-L.../G... Standard current ratings and typical internal resistance values Installation drawing Current Internal Current Internal ratings (A) resistance () ratings (A) resistance () operating area (reinforced insulation) 0.05 440 1.5 0.55 0.1 108 2 0.34 0.2 29.9 2.5 0.21 0.3 14.2 3 0.15 0.4 7.9 4 0.084 0.5 5.0 5 0.057 1 0.6 3.5 6 0.043 212 11 14 1 0.8 1.8 8 0.02 4 3 1 1.2 10 0.02 .157 .118 mounting area (standard insulation) Dimensions 2215-L1.. 4 spacer .157 Internal connection diagram I0 line 1.7 25.6 0I .067 1.01 1 11 11 .433 5 .197 12 14 212 11 14 1 I > 2.5 6 11.5 .098 .236 .453 2 29 1.14 Shock directions Dimensions 2215-G1.. 56 3 tightening torque max. 1 Nm 4 3 threadneck 1 .118 1/4 -40 UNS-2A serrated washer 2 hex nut lock washer 11 .433 blade terminals 2112 1 14 1 DIN 46244-A6.3-0.8 (QC .250) 2.5 6 .098 .236 11.5 29 .453 1.14 front panel cut-out +0.1 6.4 +.004 .252 +0.1 2.4 +.004 .094 mm This is a metric design and millimeter dimensions take precedence ( ) inch 2 www.e-t-a.de 1942 10 25 49 1.93 52.5 2.07 LINE LINE 52 14 2.05 .551 1x0.8 1.5 19 1x.031 .059 6.1 .748 .240 9 53.5 8 .354 2.11 .315 35 14 1.38 .551 LINE 19 .748 4 .157 11 16 .433 .630 I0