Thermal Circuit Breaker 3120-F... Description The 3120 circuit breaker/switch combination is an ON/OFF switch with integral overcurrent protection (S-type TO CBE to EN/IEC 60934). The trip element is a bimetal. Type 3120 is ideally suited for overload protection of motors, pumps, transformers and cables. The 3120 circuit breaker is also available as a switch-only version in accordance with the IEC/EN 61058 (see data sheet switch 3120-F-..Q1). Product characteristics: l rocker or push button actuation l single pole and double pole versions l reliable switching behaviour (positively trip-free) l convenient snap-in mounting 1 l international approvals Options and add-on modules: l illumination l water splash protection Technical data l auxiliary contacts l under voltage trip For further details please see: www.e-t-a.de/ti e l remote trip l magnetic trip Rated voltage AC 240 V, DC 50 V l push-in terminals Current rating range 0.1...20 A l appliance inlet module (up to 30A upon request for single pole units) Typical life 1-pole Typical applications AC 240 V: 0.1...20 A 30,000 operations at 1 x I , inductive N DC 50 V: 0.1...4 A 30,000 operations at 1 x I , inductive Medical and laboratory equipment, apparatus and machine N 4.5...16 A 30,000 operations at 1 x I , resistive construction, professional tools, household and garden appliances, N DC 28 V: 0.1...20 A 30,000 operations at 1 x I , inductive N offices machines, audio equipment, machine tools Typical life 2-pole Current ratings and internal resistance values AC 240 V: 0.1...16 A 50,000 operations at 1 x I , inductive N 17...20 A 30,000 operations at 1 x I , inductive N DC 50 V: 0.1...16 A 50,000 operations at 1 x I , inductive N Current rating Internal Current rating Internal 17...20 A 10,000 operations at 1 x I , inductive N (A) resistance (A) resistance Ambient temperature -30 60 C per pole () per pole () Insulation coordination 2.5 kV /2 reinforced insulation at 0.1 94 4 0.0435 (IEC 60664) operating area 0.2 24 4.5 0.0435 Dielectric strength 0.3 12 5 0.0325 Operating area test voltage AC 3,000 V pole to pole (2-pole) test voltage AC 1,500 V 0.4 5.30 6 0.0215 Insulation resistance > 100 M (DC 500 V) 0.5 4.20 7 0.0165 Interrupting capacity I 0.1...2 A 10 x I cn N 0.6 2.90 8 0.0165 2.5...20 A 1-pole 150 A 2-pole 250 A 0.8 1.50 10 < 0.02 Interrupting capacity (UL 1077) 1 0.9 12 < 0.02 I U I N N nc 1.2 0.80 14 < 0.02 1-pole, 2- pole 0.1...20 A AC 250 V 5000 A, C, 1 1.5 0.45 15 < 0.02 1-pole, 2- pole 0.1...20 A DC 50 V 1000 A, C, 1 2 0.27 16 < 0.02 Degree of protection operating area IP40 2.5 0.0785 18 < 0.02 (IEC 60529) terminal area IP00 with water splash cover IP54 or IP66 3 0.0595 20 < 0.02 Vibration 8 g (57-500 Hz), 0.61 mm (10-57 Hz) 3.5 0.0565 test to IEC 60068-2-6, test Fc 10 frequency cycles/axis Shock 30 g (11 ms) Current consumption of illumination test to IEC 60068-2-27, test Ea Corrosion 96 hours at 5 % salt mist, Operating voltage Current consumption test to IEC 60068-2-11, test Ka Y R G Humidity 240 hrs in 95 % RH DC 12 V 5.2 mA 2 mA 1.4 mA test to IEC 60068-2-78, test Cab DC 24 V 4.5 mA 2.2 mA 1.6 mA Mass approx. 33 g (2-pole) DC 48 V 4.5 mA 2 mA 1.6 mA approx. 27 g (1-pole) AC 115 V 2.8 mA 1.1 mA 1 mA approx. 42 g (2-pole with PT terminals) AC 230 V 2.2 mA 0.9 mA 0.9 mA 2051 www.e-t-a.de 1 Will be replaced by 3120-N by end of 2020 Thermal Circuit Breaker 3120-F... Order numbering code Order numbering code Type No. Type No. 3120 thermal rocker-actuated circuit breaker 3120 thermal circuit breaker with push button actuation Mounting method Mounting F flange mounting snap-in frame F flange mounting snap-in frame Size of frame Size 3 standard, to fit mounting cut-out 50.5 x 21.5 mm 2 special frame for fitting splash cover 5 standard, to fit mounting cut-out 44.5 x 22 mm 3 mounting cut-out 50.5 x 21.5 mm (panel thickness 7 special style, to fit mounting cut-out 44.5 x 22 mm 1-6.35 mm) Number of poles Number of poles 1 1-pole, thermally protected 1 1-pole, thermally protected 2 2-pole, thermally protected 2 2-pole, thermally protected 5 2-pole, 1-pole thermally protected 5 2-pole, 1-pole thermally protected 1 Mounting frame design (F3 & F5) Style 1 collar height 1 mm F frame with 2 push buttons 3 collar height 9 mm G frame with one push button (reset only) 4 collar height 2 mm with water Terminal configuration splash protection (IP54) PT push-in terminals Mounting frame design (F7) P7 blade terminals R black H7 as P7, terminals 11 and 21 with flat head T black with snap-on water splash cover screws M3.5 - standard for units with Terminal configuration undervoltage release module PT push-in terminals N7 as P7, with additional shunt terminals 12(i) P7 blade terminals and 22(i) H7 as P7, terminals 11 and 21 with flat head G7 as N7, terminals 11 and 21 with flat head screws M3.5 - standard for units with screws M3.5 undervoltage release module Characteristic curve N7 as P7, with additional shunt terminals 12(i) T1 thermal trip and 22(i) Actuators / colour / illumination G7 as N7, terminals 11 and 21 with flat head D01X 1 push button* black opaque screws M3.5 D02X 1 push button* white opaque Characteristic curve D04X 1 push button* red opaque T1 thermal trip D19XG 1 push button* green translucent Actuator style with LED illumination W rocker for frame size F3 & F5 SGRX 2 push buttons green/red opaque A rocker for frame size F7 without illumination Colour and illumination SGRXG 2 push buttons green/red translucent 01. rocker black opaque with LED illumination 02. rocker white opaque Illumination voltage range 04. rocker red opaque (= operating voltage) 14. R rocker red translucent with 1 DC 12 V LED illumination 2 DC 24 V 15. Y rocker orange translucent with 3 AC 115 V LED illumination 4 AC 230 V 19. G rocker green translucent with 5 DC 48 V LED illumination Current ratings Marking for rocker style W 0.1...20 A A 0 D 3120- F 3 2 F - P7 T1- S GRXG 4-10 A ordering example I ON Q: 0 and 1 F 0 OFF moulded in Q *reset only I AD FX X Marking for rocker style A Please be informed that we have minimum ordering quantities Q I and O moulded in to be observed. Illumination voltage range (= operating voltage) 1 DC 12 V Note 2 DC 24 V 3 AC 115 V Important: 3120-F series is replaced by 3120-N 4 AC 230 V Please refer to E-T-A homepage for further details: 5 DC 48 V