3130 Thermal Overcurrent Circuit Breaker Description Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double pole version, protection on one pole only. Illumination is optional and there is a choice of rocker colours. Approved to CBE standard EN 60934 (IEC 60934). Typical applications 1 3130 Motors, transformers, solenoids, household and office machines, electrical 1-pole 3-pole tools, mobile homes, boats, construction vehicles, medical equipment to EN 60601. Features and benefits Your benefits l Single pole, double pole or three-pole thermal circuit breaker/ l Maximum equipment availability is ensured by overload switch combination protection perfectly matched with the loads (prevention l Voltage ratings AC 240 V 3 AC 415 V DC 50 V of nuisance tripping) and quick resettability l Can be combined with X3120 Power Entry Module. Please refer l Reduced mounting and wiring time to the respective section in this document. l Less space requirement l Less disposition and storage costs l Enhanced overall reliability Approvals Information online The current data sheet is available on our website: www.e-t-a.de/d001 Compliances 2128 www.e-t-a.de 13130 Thermal Overcurrent Circuit Breaker Technical data Technical data For further details please see: www.e-t-a.de/ti e Rupture capacity I (UL1077) NC Voltage rating AC 240 V 3 AC 415 V DC 50 V I U I N N nc (UL: AC 250 V 3 AC 250 V DC 50 V) 1, 2-pole 0.1...16 A AC 250 V 3 500 A, C, 1 Current ratings 0.1...20 A 1-pole 3-pole 0.1...12 A 3 AC 250 V 5 000 A, C, 1 0.1...16 A 2- and 3-pole 1,2-pole 0.1...16 A DC 50 V 2 000 A, C, 1 Typical life 1-pole (IEC/EN 60934) AC 240 V: 0.1...20 A 30,000 operations at 1 x I , inductive Degree of protection operating area IP40 N DC 50 V: 0.1...4 A 30,000 operations at 1 x I , inductive (IEC 60529/DIN 40050) terminal area IP00 N 4.5...16 A 30,000 operations at 1 x I , resistive N Vibration 5 g (57-500 Hz) 0.38 mm (10-57 Hz) DC 28 V: 0.1...20 A 30,000 operations at 1 x I , inductive N to IEC 60068-2-6, test Fc Typical life 2-pole (IEC/EN 60934) 10 frequency cycles/axis 1 AC 240 V: 0.1...16 A 50,000 operations at 1 x I , inductive N Shock 1-pole: 25 g (11 ms) 2 + 3-pole: 20 g (11 ms) DC 50 V: 0.1...16 A 50,000 operations at 1 x I , inductive N to IEC 60068-2-27, test Ea Typical life 3-pole (IEC/EN 60934) 3 AC 415 V: 0.1...16 A 30,000 operations at 1 x I , inductive Corrosion 96 hours at 5 % salt mist, N to IEC 60068-2-11, test Ka Ambient temperature -30...+60 C (-22...+140 F) Humidity 240 hours at 95 % RH, Insulation co-ordination rated impulse pollution to IEC 60068-2-78, test Cab (IEC 60664 and 60664 A) withstand voltage degree 2.5 kV 2 Mass approx. 45 g (three pole) reinforced insulation in operating area approx. 31 g (double pole) approx. 17 g (single pole) Dielectric strength (IEC 60664 and 60664A) test voltage operating area AC 3,000 V current path/current path AC 1,500 V Insulation resistance > 100 M (DC 500 V) Interrupting capacity I (EN 60934) CN IN UN I CN 1, 2, 3-pole 0.1...2 A AC 240 V/3 AC 10 x I N 415 V 1 pole 2.520 A AC 240 V 200 A 2 pole 2.516 A AC 240 V 300 A 3 pole 2.512 A 3 AC 415 V 150 A 3 pole 1416 A 3 AC 415 V 130 A Approvals Authority Standard Rated voltage Current ratings Approval logos AC 240 V 0.1 A...20 A (1-pole) VDE IEC/EN 60934 AC 240 V 0.1A...16 A (2-pole) 3 AC 415 V 0.1A...16 A (3-pole) DC 50 V 0.1A...16 A (1-, 2-pole) DC 28 V 0.1 A20 A (1-pole) AC 250 V 0.1 A16 A (1 + 2 pole)* UL UL 1077 AC 250 V 0.1 A12 A (3 pole)* DC 50 V 0.1 A16 A (1 3 pole)* AC 250 V 0.1 A16 A (1-, 2- pole)** CSA C22.2 No 235 AC 250 V 0.1 A12 A (3-pole)* DC 50 V 0.1 A16 A (1-, 2-, 3-pole)*** AC 240 V 0.1 A...20 A (1-pole) CQC GB/T 17701 AC 240 V 0.1A...16 A (2-pole) 3 AC 415 V 0.1A...16 A (3-pole) DC 50 V 0.1A...16 A (1-, 2-pole) * TC2, OL 1 ** TC2, 0,1A-12 A: OL1, >12 A: OL0 *** TC2, OL0 2 www.e-t-a.de 2128