AC/DC SWITCHING POWER SUPPLY AC/DC SWITCHING POWER SUPPLY AACC IINNPPUUTT 8855~~226644VV SSIINNGGLLEE CCHHAANNNNEELL OOUUTTPPUUTT 110000 WWAATTTTS S BFD-SX-U1 SERIES General Description BF-Series AC/DC Switching power supplies are board type power supplies matched with new designs, which is in accordance with harmonic current regulation, of ultra-small sizes, high efficiency and low cost. By adopting the synchronization regular method (output less than 6 V) for the first time for this class of devices, BF-Series is 40mm smaller in depth compared with equivalent products by other makers. At the same time low cost is realized to meet market needs. Application Features Industrial 1. Board Type Input 2. Ultra Small size AC100-240V 3. Universal input(AC 85V to 264V) Input Voltage: AC85-264V 4. Harmonic current complies to IEC61000-3-2 Input Voltage Range: 5. Power factor BFD: 0.98/0.92 (AC 100/230V) 2.0-0.9 A Input Current: 6. High efficiency 50/60Hz Frequency: 7. Low Cost 47-63Hz Input Frequency Range: 8. EMI: complies to FCC class B, or EN55022 Phase: Single class B, or VCCI class B 18A(typ.) at AC100V Inrush Current: *1 nd 9. Safety: UL 60950-1 2 edition, C-UL, 41A(typ.) at AC230V EN 60950-1 2006 Leakage Current: 1mA(maximum)at 25 C (rated input/output and Options rated input frequency) N/A ETA USA 16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.eta-usa.com Phone: 1-800-ETA-POWER, (408) 778-2793 Fax: (408) 779-2753 email at: sales eta-usa.com Models Output Unit BFD3.3SX BFD05SX BFD06SX BFD09SX BFD12SX BFD15SX BFD24SX BFD36SX BFD48SX Characteristic Vdc 3.3 5 6 9 12 15 24 36 48 Output Voltage A 20 20 17 11.4 8.6 7.0 4.5 3.0 2.3 Output Current V Voltage Adjust Range 10% of Rated Output Voltage(at no load within the input range) mVpp 120/160 Ripple&Noise(max)*2 150 at 0 to 40 C /180 at -10 to 0 C mS Rise up time 500mS(maximum) at 25C and rated input/output mS Hold up time 20mS(minimum) at 25C and rated input/output Regulation mV 9.9 15 18 27 36 45 72 108 144 a. Line Regulation mV 40 40 40 40 40 100 150 150 150 b. Load Regulation *3 C c. Temperature 0.03 %/ C Coefficient *4 mV 13.2 20 24 36 48 60 96 144 192 d. Drift(maximum) *5 mV e. Dynamic Load 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.5 Regulation (typ.) *6 mS f. Recovery Time *6 5 mS(typ.) % 77/79 80/84 81/85 81/85 82/86 83/87 84/87 84/88 86/89 Efficiency 0.97/0.92 0.98(typical) at AC100V/0.92(typical) at AC230V Power Factor ETA USA 16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.eta-usa.com Phone: 1-800-ETA-POWER, (408) 778-2793 Fax: (408) 779-2753 email at: sales eta-usa.com