Electronic Circuit Protector ESX10-T.-DC 24 V Description E-T-As ESX10-T electronic circuit protector is only 12.5 mm wide and selectively protects all DC 24 V load circuits, thereby increasing the uptime of machines and systems. This is achieved by a combination of active electronic current limitation in the event of a short circuit and overload disconnection typically from 1.1 times rated current. The ESX10-T responds faster than frequently used DC 24 V switch mode power supplies without tripping fast and thus prevents disastrous voltage dips of the supply. It works with a single trip curve for all loads. Even capacitive loads up to 75,000 F can be handled very easily. Besides fixed current ratings from 0.5 A to 12 A, adjustable current rating versions are also available. The integral fail-safe element (fuse) is adjusted to the circuit protectors rated current and can thus very easily be synchronised with the wired cable cross section. This makes planning much easier. ESX10-TD Features Your benefits l l Track-mountable Increases machine uptime through clear failure detection and l stable power supply Active linear current limitation l l Reduces downtimes through quick fault resolution Capacitive loads up to 75,000 F l l Simplifies planning through clear sizes and ratings ESX10-TA/-TB: fixed current ratings 0.5 A12 A l l Saves costs and time through fast and flexible mounting including ESX10-TD: adjustable current ratings, e.g. 0,5 A / 1 A / 2 A integral power distribution solution 2 A / 4 A / 6 A 6 A / 8 A / 10 A l Approvals: UL, CSA, GL l OPTION: Control inputs, signalling l OPTION: ATEX approval Preferred types for more details on all configurations please see order numbering code Preferred types are E-T-A products most frequently used by E-T-A volumes. Our preferred types are supplied at shorter lead times than customers. We manufacture E-T-A preferred types in particularly high non-standard versions. Preferred types Short description Preferred ratings (A) 4 ESX10-TA/-TB fixed current rating 0.5 1 2 3 4 6 8 10 12 0.5/1/2 2/4/6 6/8/10 ESX10-TA-100-DC24V- without auxiliary contacts auxiliary contact ESX10-TB-101-DC24V- make contact ESX10-TD adjustable current rating 0.5 1 2 3 4 6 8 10 12 0.5/1/2 2/4/6 6/8/10 auxiliary contact ESX10-TD-101-DC24V- make contact Approvals Information online For access to the latest documents please follow: Electronic Circuit Protector ESX10-T.-DC 24 V Electronic Circuit Protector ESX10-T.-DC 24 V Technical data (T = 25 C, U = DC 24 V) Technical data (T = 25 C, U = DC 24 V) amb B amb B Operating data Free-wheeling diode exter nal free-wheeling diode recommended for inductive load Operating voltage U DC 24 V (18...32 V) B Parallel connection of several load outputs Current ratings I fixed rating: N not permitted Types ESX10-TA-... and -TB-...: Signal output F ESX10-T.-101/-102 0.5 A, 1 A, 2 A, 3 A, 4 A, 6 A, 8 A, 10 A, 12 A adjustable current ratings: Electrical data potential-free auxiliary change-over type ESX10-TD-...: contact max. DC 30 V/0.5 A min. 10 V/10 mA 0.5 A/1 A/2 A , 2 A/4 A/6 A , 6 A/8 A/10 A Standard condition U is applied and switch S1 is ON and B Standby current I in ON condition: typically 20 ... 30 mA 0 LED green no overload, no short circuit depending on signal output l OFF condition, LED off device switched off (switch S1 to OFF) l Visual status multicoloured LED: l no operating voltage U B indication via green: Fault condition LED orange overload conditions > 1.1 times I until N - device is ON (S1 = ON) electronic disconnection - load circuit/Power-MOSFET connected Fault condition LED red electronic disconnection after orange: overload or short circuit - overload or short circuit until electronic disconnection ESX10-TB-101 single signal, make contact red: contact open, terminal 13-14 - device switched OFF electronically ESX10-TB-102 single signal, make contact - load circuit/Power-MOSFET contact closed, terminal 11-12 disconnected Error signal output is in fault condition, if - undervoltage (U < 8 V) B l there is no operating voltage U - after switch-on until the end of the B l the ON/OFF switch S1 is in OFF posi- switch-on delay period tion OFF: l the red LED is lighted - manually switched off (S1 = OFF) or (electronic disconnection) device is dead-voltage l status output SF (optional) Status output SF ESX10-T.-114/-124/-127 l potential-free signal contact F (optional) Electrical data plus switching signal output, l On/off position of the switch S1 connects U to pin 23 B Load circuit Current ratings: DC 24 V/max. 0.2 A (short circuit proof) Load output power MOSFET switching output The status output is connected internally (plus switching) with a 10 kOhm resistor against 0 V. Overload disconnection (OL) typically 1.1 x I (1.05...1.35 x I ) N N Status OUT ESX10-TB-114/-124 (signal status OUT), Short circuit current I active current limitation with K at U = + 24 V B I = typically 1.8/1.5/1.4/1.3 x I , Limit N + 24 V = S1 is ON, load output connected 4 I depending on I Limit N 0 V = S1 is ON, load output locked (typically I - values, see table 1) Limit and/ or switch S1 is OFF Trip times see time/current characteristic red LED lighted Trip thresholds/trip 1. threshold: Status OUT ESX10-TB-127 (signal status OUT times (t , t ) at overcurrent at I > typically 1.1 x I ...I : 1 2 load N Limit inverted), at U = + 24 V B (I see table 1) t = typically 3 s Limit 1 + 24 V = S1 is ON, load output locked 2. threshold: red LED lighted. at I = I : load Limit 0 V = S1 is ON, load output connected t = typically 100 ms...3 s 2 and/or switch S1 is OFF. Temperature disconnection internal temperature monitoring with OFF condition 0 V level at status output whenever: electronic disconnection l switch S1 is in ON position, but device is still in ON delay Low voltage monitoring l switch S1 in OFF position, or control of load output with hysteresis, no reset required signal OFF, device is switched off load OFF at U < 8 V B l No operating voltage U B Switch-on delay typically 0.5 s Reset input RE ESX10-T.-124/-127 t after each ON operation, after reset and Start after applying of U B Electrical data voltage max. DC 32 V High > DC 8 V DC 32 V Disconnection of electronic disconnection after Low < DC 3 V > 0 V load circuit overload/short circuit current consumption typically 2.6 mA (DC 24 V) min. pulse duration 10 ms 2 www.e-t-a.de 1822