240 WATT AC-DC CONVERTER PFE-HSX SERIES Features Low line distortion Power Factor correction Pulse load response Cost effective Designed for peak loads (twice rated output) Universal input General Description PF-Series AC/DC Switching power supplies has been designed to meet harmonic current distortion. PF series Options has the 75 W PFC with the peak of 150 W, the 120W PFD with peak of 240W and 240 W PFE with peak of 480 W. They are *Cover (add suffix -P) suitable for motor drive. *Wire/harness 40cm *Remote control (add suffix -R ir -RR) Application Broad needs Input Certified: AC100-230V Input Voltage: AC85~264V Input Voltage Range: RoHS E176763 50/60Hz Frequency: 47-63Hz Frequency Range: Single Phase: Inrush Current: *1 18A(max) at AC100VAC 40A (Typ.) 230VAC ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales eta-usa.com Specifica tio ns Model PFE**H SX PFE 1 2 H SX PFE 2 4 H SX PFE 3 6 H SX 24 0W A T T S (Pea k 4 0 0 to 48 0W )/ S I N G L E Input V o ltag e A C100-230V Input Cu rrent 4.0-1.8A Input Range A C85-264V Input Frequency 50/60H z Input Frequency Range 47-63H z Ph ase Single In ru sh Cu rren t * 1 18A (m ax im um ) at A C100V /40A (m ax im um ) at A C230V E fficien cy % (ty p ical) * 2 78/81 82/85 83/86 Po w er Facto r 0.99(typical) at A C100V /0 .95(typical) at A C230V Ou tp u t Vo ltag e V 12 24 36 O u tp u t Cu rren t A 18(Peak36) 10(Peak20) 6.7(Peak13.4) Vo ltag e Ad ju st Ran g e +/- 10% of Rated O u tput V o ltag e(at no lo ad w ith in th e input range) R ipple and N oise m V p-p (maximum) *3 300 300 300 Regulation a.Line Regulation m V (m ax im um ) 60 120 180 b.L o ad Regulation m V (m ax im um ) 120 240 360 o c.T em p eratu re Co efficien t * 4 0.03% / C d.D rift m V (m ax im um ) *5 75 135 195 e .D yna m ic L oa d Re gula tion m V ( typic a l) *6 360 720 1080 f.Recovery Tim e *6 0.5m S(typical) o Rise up tim e 500m S(m axim u m ) at 25 C and rated input/output o H o ld up tim e 50m S(m inim u m ) at 25 C and rated input/output O v ercu rren t Pro tectio n Cu rrent L im iting w ith au to m atic recovery O v ervoltage Protection output shutdow n(to reset,leav e 3m inutes after shut-o ff) >=115% of Rated O u tput V o ltag e V 13.8 27.6 41.4 Rem o te Sen se not av ailable Rem o te O n /O ff option Po w er Fail D etectio n not av ailable Parallel/series O p eratio n not av ailable o O p erating T em p erature *7 -10 to +4 5 C O p erating H u m idity 20 to 85% /RH (non-condensing) o Sto rag e T em p eratu re -20 to +8 5 C Storag e H u m idity 10 to 85% /RH (non-condensing) W ith standing V o ltag e Prim ary-Secondary A C3,000V fo r 1m inute Prim ary-Fram e G round A C2,500V fo r 1m inute Secondary -Fram e G round A C500V fo r 1m inute Isolation Resistan ce Prim ary-Secondary -Fram e G round 50M (m in im um ) by D C500V in su lation tester 2 Vibration 5-10H z:10m m double am plitude,10-55H z:19.6m /s,20m inutes period fo r 60m inutes each along X ,Y ,Z ax es(non-operating) 2 Shock 294m /s Cooling Convection o L eak ag e Cu rren t 0.75m A (m axim u m ) at 25 C,rated input/output and rated input frequency L ine Conducted N o ise Bu ilt to m eet FCC Part1 5 -B Class B Bu ilt to m eet V CCI Class B Bu ilt to m eet E N 55022 Class B L ine H am onic D istortion Bu ilt to m eet IE C1000-3-2 Safety Bu ilt to m eet U L 1950 Bu ilt to m eet CSA C2 2 .2 N o .9 5 0 Bu ilt to m eet EN 60950, IE C950, V D E 0805 W eight (typical) 1200g/en closed type:1400g MT BF H 229,000 Sw itch ing Frequency kH z (typical) 140 Conditions: * 1 at co ld start o *2 at A C100/230V input,rated output and 25 C *3 m easured by a bayonet probe at th e output connector at a 0 to 100M H z bandw id th o *4 at -10 to +4 5 C o *5 fo r 7hour period after 1hour w arm -up at 25 C and rated input/output *6 w h en output cu rrent ch anged fro m 50% to 150% of rated output cu rrent rapidly at rated input o *7 safety approved at 25 C ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales eta-usa.com