- external RESET input u l. K o n s ta n ty n o w s k a 7 9 /8 1 9 5 -2 0 0 P a b ia n ic e - relay output signaling the preset meter state (contact1C/O 8A) te l/ fa x 4 8 4 2 2 2 7 0 9 7 1 P O L A N D - local counter , reset using the external reset input or using e -m a il : fi f fi f. c o m .p l RESET button - total counter for all impulses (loop mode 0 99 999 999 0 ... C C L L I I - - 0 0 1 1 or reset using the meter configuration menu) - digital filter , enabling the limiting of maximum frequency of the P U L S E M E T E R counted pulses (in order to reduce interferences on meter input) - local and total meter state memory after supply failure - program menu in three languages: Polish, English or Russian Description of display and control panel The services and programming meter CLI-01 is used mounted on the casing front panel control. It consists of a two lines, eight alphanumeric 5 9 0 8 3 1 2 5 9 1 7 6 4 display , and placed under it keyboard with five buttons. w w w . f i f . c o m . p l F& F p rod uc ts are co ve red by an 24 m on ths w arr an ty fro m da te of pu rch as e T wo lineseight CL I-0 1 alphanumeric display PURPOSE Control T OT AL: buttons 01304569 Pulse meter is intended for counting AC/DC voltage signals, generated by additional peripheral devices in order to determine RESET MENU OK p q the number of carried out working cycles in automatics systems, e.g. in order to control the number of press strokes, the number of revolutions of a rotating device, the number of components Display present information about the current state of work, and in leaving the production line, etc. programming mode allows the configuration of the meter parameters. The buttons on the control panel, perform the following METER FUNCTIO NS functions: - control panel, enabling programming and the monitoring of device operation Button functions: - T input, adapted for operation with AC/DC signal, 5 to 264V MENU MENU - pass to programming mode. In the cause that the meter amplitude and 50 Hz frequency for AC and 5kHz for DC signals is working in the editing parameter mode, of a number , press this - possibility to set THRESHOLD parameter (199 999 999 button to go to the next edition of the digits. range), specifying the limiting number of pulses counted in a single operation cycle p Device status is indicated by messages on the display . During the UP and DOWN - to select the next position of menu, and to counting of pulses on the display , see the following information: increase or decrease value of editing parameter . q OK OK - pass to choosen position of menu and to enter changes Status of transformer RE SE T - re se tt in g to th e cu rr en t me te r cy cl e. In Signalization RESET output work of meter programming mode allows return to main menu If the (open joint) RESET button is pressed while editing a parameter , it go out from edit mode without saving changes. Signalization read of pulses >> FUNCTIONING 00000999 Meter CLI-01 is a one-way meter which count to up. Pulses are Actual counted from zero to a value set by the user . reports of meter S E S L The achievement of the set value is indicated by closure of relay U P joints. At the same time stops counting pulses, the illumination of display blinking three times, and the display shows the message T ST OP . E S E R 3sec Status of transformer Signalizaton achievement SET V ALUE output of the set value (open joint) R E T A M ST OP 00002000 ON. T Actual and set N I value of meter O JThe start of a new cycle is possible only after reset meter from the control panel by pressing the RESET button, or via an external OK reset input. T o protect the system against accidental erasure state >> MENU of the counter , a zero signal is activated only after three seconds THRESHOLD after pressing the RESET button or give a signal to enter reset. 00000999 MENU MENU Behind of local meter which is reset after work the button RESET SIGNAL the system is equipped with a total count, which caunt all pulses p and reset in a cuse when get full or reset from main menu. T o read MENU the value of the total meter, press OK. FiltrDC q MENU SET ZERO MENU RESET L ANGUAGE >> T OT AL: 00000999 00029867 OK tT o select menu use buttons UP or DOWN. Pass to choosen menu is possible by pressing button OK. Return to main menu is make by pressing button RESET . A TTENTION Counter stores its current state after turning off the voltage. This Menu of meter means that after you re-enable system restore is fed both the meter and the total meter, as well as the transmitter output. 1. Threshold This parameter determines the number of pulses which to be count in each cycle. PROGRAMMING After selected the menu Threshold, press OK. Meter goes into Meter configuration is make by a control panel with a keyboard edit mode, and the digit being edited is indicated by pulsing and display . Passing the programming mode the meter is done by cursor . Use the buttons UP and DOWN to set a value on an item pressing the MENU button. number , then use the MENU button to move the cursor to the next digit. After setting all the required numbers, enter a new value by pressing the OK button. The parameter changes are indicated by the message saved and RESET given the value of the parameter . In edit mode, you can return by pressing the RESET button, which will result in the abandonment MENU SIGNAL SA VED of the changes and return to main menu SIGNAL CONT . DC CONT . DC OK OK p RESET SIGNAL SA VED THRESHOLD q MENU AC 50Hz AC 50Hz THRESHOLD 00000000 OK OK RESET MENU p +1 q -1 After select a menu signal, press OK. Then, using the UP and DOWN buttons to select the appropriate type of signal and enter the selection with the OK button. Entered message is the record of the name stored measured signal. Exit menu without saving THRESHOLD the changes implemented by pressing the RESET button. 00012000 RESET A TTENTION Choosing the type of count input signal is also the choice of type signal for the RESET input. SA VED 00012000 OK 3. FiltrDC 2. Signal (INPUT ) FiltrDC menu is used to define the parameters of the internal digital filter . It can help reduce frequency counting pulses to the set value, and thus reduce the possibility of wrong work of system Menu signal determines whether to implement the counter caused by interference, such as by contact vibration systems. counting pulses of DC signals or signals for the AC (with a Diagram of the digital filter configuration is presented in the maximum frequency of 50Hz). How to set the measured signal is following picture: presented in the following picture: