u l. K o n s ta n ty n o w s k a 7 9 /8 1 9 5 -2 0 0 P a b ia n ic e FUNCTIONING te l/ fa x 4 8 4 2 2 2 7 0 9 7 1 P O L A N D e -m a il : fi f fi f. c o m .p l Three-phase voltage (3x230V+N) is supplied to the input of the switch. Single-phase voltage (230V AC), i.e. the phase voltage of P P F F - - 4 4 3 3 1 1 one of the phases, is supplied to the output of the switch. The electronic system of the switch controls voltage values of the A U T O M A T I C P H A S E S W I T C H E S phases supplied in such a way as to ensure that output voltage is not lower than 195V . The phase that has correct parameters is directed to the output of the switch. The L1 phase is the priority phase, i.e. if its parameters are correct, this phase will be always switched to the output. If the voltage parameters of the L1 phase are not correct or if voltage decay occurs in this phase, the electronic system will switch the L2 phase to the output (provided 5 9 0 8 3 1 2 5 9 4 0 2 4 > that its parameters are correct). In case of a simultaneous lack of w w w . f i f . c o m . p l correct voltages in the L1 and L2 phases, the L3 phase will be switched to the output. When the correct supply voltage returns to F& F p rod uc ts are co ve red by an 24 m on ths w arr an ty fro m da te of pu rch as e the L1 phase (upper than 195V), the electronic system will switch this phase to the output. PURPOSE A utomatic phase switches serve to maintain continuity of power ASSEMBL Y supply to single-phase receivers in the event of power phase decay or a drop in its parameters below standard values. 1. T ake OFF the power . 2. Connect inputs voltage to joints 3,4,5, and neutral cable to joint 6. The phase with the event of power connect to joint 5, but the stablest phase to joint 3 as main. 3. Supplied one phase line connect to joint 12 (phase) and neutral cable (installation). 4. T ake On the power and check continuity of power supply of connected one phase configuration by successive switch OFF the voltage from phases L1, next L2. TECHNICAL DA T A supply 3400V+N output 230V AC current load <16A voltage activation treshold for L1 and L2 (lower/upper) <195V/ > 250V for L3 (lower/upper) <190V/ > 250V hysteresis 5V switching time 0,50,8sec sygnalling of supply 3LED working temperature -25 50 C connection screw terminals 2 ,5mm dimensions 3 modules (52,5mm) fixing on rail TH-35 WIRING DIAGRAM N L 3 L 2 L 1 1 2 3 4 5 6 N 7 8 9 1 0 1 1 1 2 L A090619X-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for General Purpose Relays category: Click to view products by F&F manufacturer: Other Similar products are found below : APF30318 JVN1AF-4.5V-F PCN-105D3MHZ 5JO-10000S-SIL 5JO-1000CD-SIL 5JO-400CD-SIL LY2S-AC220/240 LYQ20DC12 6031007G 6131406HQ 6-1393099-3 6-1393099-8 6-1393122-4 6-1393123-2 6-1393767-1 6-1393843-7 6-1415012-1 6-1419102-2 6- 1423698-4 6-1608051-6 6-1608067-0 6-1616170-6 6-1616248-2 6-1616282-3 6-1616348-2 6-1616350-1 6-1616350-8 6-1616358-7 6- 1616359-9 6-1616360-9 6-1616931-6 6-1617039-1 6-1617052-1 6-1617090-2 6-1617090-5 6-1617347-5 6-1617353-3 6-1617801-8 6- 1617802-2 6-1618107-9 6-1618248-4 M83536/1-027M CX-4014 MAHC-5494 MAVCD-5419-6 703XCX-120A 7-1393100-5 7-1393111-7 7-1393144-5 7-1393767-8