22 Series - Modular contactors 25 A Features 22.32.0.xxx.1xx0 22.32.0.xxx.4xx0 25 A modular contactor - 2 pole 17.5 mm wide NO contact gap 3 mm, double break Continuous duty for the coil and contacts AC/DC silent coil (with varistor protection) Protective separation (reinforced insulation) between coil and contacts Mechanical and LED indicators as standard Auto-On-Off selector version available AgSnO contacts, specifically AgNi contacts, specifically 2 AgNi and AgSnO contact versions available 2 intended for resistive and intended for lamp loads and Compliant with EN 61095: 2009 slightly inductive loads as for high inrush current loads Auxiliary contact module available, well as for motor loads quick-assembly with the main contactor (1 NO + 1 NC and 2 NO versions) 35 mm rail (EN 60715) mount 22.32...1xx0 / 22.32...4xx0 Screw terminal 2 NO 1 NO + 1 NC 2 NC (x3x0) (x5x0) (x4x0) * Contact gap 3 mm for NO contacts only NC contacts 1.5 mm For outline drawings see page 7 Contact specification Contact configuration 2 NO, 3 mm * (or 1 NO + 1 NC or 2 NC) Rated current/Maximum peak current A 25 / 80 25 / 120 Rated voltage V AC 250 / 440 250 / 440 Rated load AC1 / AC-7a (per pole 250 V) VA 6,250 6,250 Rated current AC3 / AC-7b A 10 10 Rated load AC15 (per pole 230 V) VA 1,800 1,800 Single-phase motor rating (230 V AC) kW 11 Rated current AC-7c A 10 230 V lamps rating: incandescent or halogen W 2,000 compact fluorescent (CFL) W 200 electronic ballast fluorescent tubes W 800 electromagnetic ballast compens. fluorescent tubes W 500 Breaking capacity DC1: 30/110/220 V A 25/5/1 25/5/1 Minimum switching load mW (V/mA) 1,000 (10 / 10) 1,000 (10 / 10) Contact material AgNi AgSnO 2 Coil specification Nominal voltage (U ) V DC/AC (50/60 Hz) 12 - 24 - 48 - 60 - 120 - 230 12 - 24 - 48 - 60 - 120 - 230 N Rated power AC/DC VA (50 Hz)/W 2 /2.2 2 / 2.2 Operating range DC/AC (50/60 Hz) (0.8 1.1) U (0.8 1.1) U N N Holding voltage DC/AC (50/60 Hz) 0.4 U 0.4 U N N Must drop-out voltage DC/AC (50/60 Hz) 0.1 U 0.1 U N N Technical data 6 6 Mechanical life AC/DC cycles 2 10 2 10 3 3 Electrical life at rated load AC-7a cycles 70 10 30 10 Operate/release time ms 30 / 20 30 / 20 Insulation between coil and contacts (1.2/50 s) kV 66 Ambient temperature range C 20+50 20+50 Protection category IP20 IP20 Approvals (according to type) 122 Series - Modular contactors 25 A Features 22.34.0.xxx.1xx0 22.34.0.xxx.4xx0 25 A modular contactor - 4 pole 35 mm wide NO contact gap 3 mm, double break Continuous duty for the coil and contacts AC/DC silent coil (with varistor protection) Protective separation (reinforced insulation) between coil and contacts Mechanical and LED indicators as standard Auto-On-Off selector version available AgSnO contacts, specifically AgNi contacts, specifically 2 AgNi and AgSnO contact versions available 2 intended for resistive and intended for lamp loads and Compliant with EN 61095: 2009 slightly inductive loads as well for high inrush current loads Auxiliary contact module available, as for motor loads quick-assembly with the main contactor (1 NO + 1 NC and 2 NO versions) 35 mm rail (EN 60715) mount 22.34...1xx0 / 22.34...4xx0 Screw terminal 4 NO 3 NO + 1 NC 2 NO + 2 NC (x3x0) (x7x0) (x6x0) * Contact gap 3 mm for NO contacts only NC contacts 1.5 mm For outline drawings see page 7 Contact specification Contact configuration 4 NO, 3 mm * (or 3NO + 1NC or 2NO + 2NC) Rated current/Maximum peak current A 25 / 80 25 / 120 Rated voltage V AC 250 / 440 250 / 440 Rated load AC1 / AC-7a (per pole 250 V) VA 6,250 6,250 Rated current AC3 / AC-7b A 10 10 Rated load AC15 (per pole 230 V) VA 1,800 1,800 Three-phase motor rating (400 - 440 V AC) kW 44 Rated current AC-7c A 10 230 V lamps rating: incandescent or halogen W 2,000 compact fluorescent (CFL) W 200 electronic ballast fluorescent tubes W 800 electromagnetic ballast compens. fluorescent tubes W 500 Breaking capacity DC1: 30/110/220 V A 25/5/1 25/5/1 Minimum switching load mW (V/mA) 1,000 (10 / 10) 1,000 (10 / 10) Contact material AgNi AgSnO 2 Coil specification Nominal voltage (U ) V DC/AC (50/60 Hz) 12 - 24 - 48 - 60 - 120 - 230 12 - 24 - 48 - 60 - 120 - 230 N Rated power AC/DC VA (50 Hz)/W 2 / 2.2 2 / 2.2 Operating range DC/AC (50/60 Hz) (0.8 1.1) U (0.8 1.1) U N N Holding voltage DC/AC (50/60 Hz) 0.4 U 0.4 U N N Must drop-out voltage DC/AC (50/60 Hz) 0.1 U 0.1 U N N Technical data 6 6 Mechanical life AC/DC cycles 2 10 2 10 3 3 Electrical life at rated load AC-7a cycles 150 10 30 10 Operate/release time ms 18 / 40 18 / 40 Insulation between coil and contacts (1.2/50 s) kV 66 Ambient temperature range C 20+50 20+50 Protection category IP20 IP20 Approvals (according to type) 2