40 SERIES 40 Series - Miniature PCB/Plug-in relays 8 - 10 - 12 - 16 A Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31 - 1 Pole 10 A (3.5 mm pin pitch) A 40.51 - 1 Pole 10 A (5 mm pin pitch) 40.52 - 2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail mount - via screw and screwless sockets DC coils (standard or sensitive) & AC coils Cadmium Free contact material 3.5 mm contact pin pitch 5 mm contact pin pitch 5 mm contact pin pitch 8 mm, 6 kV (1.2/50 s) isolation, coil-contacts 1 Pole 10 A 1 Pole 10 A 2 Pole 8 A UL Listing (certain relay/socket combinations) PCB or 95 series sockets PCB or 95 series sockets PCB or 95 series sockets Flux proof: RT II standard, (RT III option) 95 series sockets Coil EMC suppression Timer accessories 86 series FOR UL RATINGS SEE: Copper side view Copper side view Copper side view General technical information page V Pin length 5.3 mm for Pin length 5.3 mm for Pin length 5.3 mm for PCB or sockets PCB or sockets PCB or sockets For outline drawing see page 10 Contact specification Contact configuration 1 CO (SPDT) 1 CO (SPDT) 2 CO (DPDT) Rated current/Maximum peak current A 10/20 10/20 8/15 Rated voltage/Maximum switching voltage V AC 250/400 250/400 250/400 Rated load AC1 VA 2,500 2,500 2,000 Rated load AC15 (230 V AC) VA 500 500 400 Single phase motor rating (230 V AC) kW 0.37 0.37 0.3 Breaking capacity DC1: 30/110/220 V A 10/0.3/0.12 10/0.3/0.12 8/0.3/0.12 Minimum switching load mW (V/mA) 300 (5/5) 300 (5/5) 300 (5/5) Standard contact material AgNi AgNi AgNi Coil specification Nominal voltage (U ) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 N V DC 5 - 6 - 7 - 9 - 12 - 14 - 18 - 21 - 24 - 28 - 36 - 48 - 60 - 90 - 110 - 125 Rated power AC/DC/sens. DC VA (50 Hz)/W/W 1.2/0.65/0.5 1.2/0.65/0.5 1.2/0.65/0.5 Operating range AC (0.81.1)U (0.81.1)U (0.81.1)U N N N DC/sens. DC (0.731.5)U /(0.731.5)U (0.731.5)U /(0.731.5)U (0.731.5)U /(0.731.5)U N N N N N N Holding voltage AC/DC 0.8 U /0.4 U 0.8 U /0.4 U 0.8 U /0.4 U N N N N N N Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U /0.1 U 0.2 U /0.1 U N N N N N N Technical data 6 6 6 Mechanical life cycles 10 10 10 10 10 10 3 3 3 Electrical life at rated load AC1 cycles 200 10 200 10 100 10 Operate/release time ms 7/3 - (12/4 sensitive) 7/3 - (12/4 sensitive) 7/3 - (12/4 sensitive) Insulation between coil and contacts (1.2/50 s) kV 6 (8 mm) 6 (8 mm) 6 (8 mm) Dielectric strength between open contacts V AC 1,000 1,000 1,000 Ambient temperature range C 40+85 40+85 40+85 Environmental protection RT II** RT II** RT II** Approvals (according to type) 1 ** See general technical information Guidelines for automatic flow solder processes page II . VI-2014, www.findernet.com40 SERIE S 40 Series - Miniature PCB/Plug-in relays 8 - 10 - 12 - 16 A Features 40.61 40.xx.6 40.61 - 1 Pole 16 A (5 mm pin pitch) 40.xx.6 - Bistable versions of the 40.31, A 40.51, 40.52 & 40.61 relays PCB mount - direct or via PCB socket 35 mm rail mount - via screw and screwless sockets DC coils & AC coils Cadmium Free option available 8 mm, 6 kV (1.2/50 s) isolation, coil-contacts 5 mm contact pin pitch Bistable (single coil) versions UL Listing 1 Pole 16 A of 40.31/51/52/61 (certain 40.61 relay/socket combinations) PCB or 95 series sockets PCB or 95 series sockets Flux proof: RT II standard, (RT III option) 95 series sockets Coil EMC suppression Timer accessories 86 series Bistable version (1 coil) types: 40.31.6... 40.51.6... 40.52.6... 40.61.6... For wiring diagrams see page 9 FOR UL RATINGS SEE: Copper side view General technical information page V Pin length 5.3 mm for Pin length 5.3 mm for For outline drawing see page 10 PCB or sockets PCB or sockets Contact specification Contact configuration 1 CO (SPDT) Rated current/Maximum peak current A 16/30* * With the AgSnO material 2 the maximum peak current is Rated voltage/Maximum switching voltage V AC 250/400 See relays 120 A - 5 ms on normally Rated load AC1 VA 4,000 40.31 open contact. Rated load AC15 (230 V AC) VA 750 40.51 Single phase motor rating (230 V AC) kW 0.55 40.52 Breaking capacity DC1: 30/110/220 V A 16/0.3/0.12 40.61 Minimum switching load mW (V/mA) 500 (10/5) Standard contact material AgCdO Coil specification Nominal voltage (U ) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 5 - 6 - 12 - 24 - 48 - 110 N V DC ***See table 5 - 6 - 12 - 24 - 48 - 110 *** Nominal voltage (U ): N 5 - 6 - 7 - 9 - 12 - 14 - 18 - 21 - Rated power AC/DC/sens. DC VA (50 Hz)/W/W 1.2/0.65/0.5 1.0/1.0/ 24 - 28 - 36 - 48 - 60 - 90 - Operating range AC (0.81.1)U (0.81.1)U N N 110 - 125 V DC DC/sens. DC (0.731.5)U /(0.81.5)U (0.81.1)U / N N N Holding voltage AC/DC 0.8 U /0.4 U N N Must drop-out voltage AC/DC 0.2 U /0.1 U N N Technical data 6 Mechanical life cycles 10 10 See relays 3 Electrical life at rated load AC1 cycles 100 10 40.31 Operate/release time ms 7/3 - (12/4 sensitive) 40.51 Insulation between coil and contacts (1.2/50 s) kV 6 (8 mm) 40.52 Dielectric strength between open contacts V AC 1,000 40.61 Ambient temperature range C 40+85 Min. impulse duration Environmental protection RT II** 20 ms Approvals (according to type) 2 ** See general technical information Guidelines for automatic flow solder processes page II. VI-2014, www.findernet.com