4C SERIES 4C Series - Relay interface modules 8 - 10 - 16 A Features 4C.01 4C.02 1 & 2 pole relay interface modules, screw terminal socket, 15.8 mm wide. Ideal interface for PLC and electronic systems 4C.01 - 1 Pole 16 A 4C.02 - 2 Pole 8 A AC coils or DC coils B Instant ejection of relay using plastic retaining clip Supply status indication and coil suppression 1 pole, 16 A 2 pole, 8 A module as standard Screw terminal connection Screw terminal connection Identification label 35 mm rail (EN 60715) 35 mm rail (EN 60715) UL Listing (certain relay/socket combinations) mounting mounting 35 mm rail (EN 60715) mounting 4C.01 / 4C.02 Screw terminal For outline drawing of 4C.01/02 see page 5 Contact specification Contact configuration 1 CO (SPDT) 2 CO (DPDT) Rated current/Maximum peak current A 16/25 8/15 Rated voltage/Maximum switching voltage V AC 250/440 250/440 Rated load AC1 VA 4,000 2,000 Rated load AC15 (230 V AC) VA 750 350 Single phase motor rating (230 V AC) kW 0.55 0.37 Breaking capacity DC1: 30/110/220V A 16/0.5/0.15 6/0.5/0.15 Minimum switching load mW (V/mA) 300 (5/5) 300 (5/5) Standard contact material AgNi AgNi Coil specification Nominal voltage (U ) V AC (50/60 Hz) 12 - 24 - 110 - 120 - 230 12 - 24 - 110 - 120 - 230 N V DC 12 - 24 - 125 12 - 24 - 125 Rated power AC/DC VA (50 Hz)/W 1.2/0.5 1.2/0.5 Operating range AC (0.81.1)U (0.81.1)U N N DC (0.731.1)U (0.731.1)U N N Holding voltage AC/DC 0.8 U /0.4 U 0.8 U /0.4 U N N N N Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U /0.1 U N N N N Technical data 6 6 Mechanical life AC/DC cycles 10 10 10 10 3 3 Electrical life at rated load AC1 cycles 100 10 100 10 Operate/release time ms 15/5 (AC) - 15/12 (DC) 10/3 (AC) - 10/10 (DC) Insulation between coil and contacts (1.2/50 s) kV 6 (8 mm) 6 (8 mm) Dielectric strength between open contacts V AC 1,000 1,000 Ambient temperature range C 12A: 40+70/>12A: 40+50 40+70 Protection category IP 20 IP 20 Approvals - relay (according to type) 1 X-2013, www.findernet.com4C SERIE S 4C Series - Relay interface modules 8 - 10 - 16 A Features 4C.51 4C.52 1 & 2 pole relay interface modules, screwless terminal socket, 15.8 mm wide. Ideal interface for PLC and electronic systems 4C.51 - 1 Pole 10 A 4C.52 - 2 Pole 8 A AC coils or DC coils B Instant ejection of relay using plastic retaining clip Supply status indication and coil suppression 1 pole, 10 A 2 pole, 8 A module as standard Screwless terminal connections Screwless terminal connections Identification label 35 mm rail (EN 60715) 35 mm rail (EN 60715) UL Listing (certain relay/socket combinations) mounting mounting 35 mm rail (EN 60715) mounting 4C.51 / 4C.52 Screwless terminal For outline drawing of 4C.51/52 see page 5 Contact specification Contact configuration 1 CO (SPDT) 2 CO (DPDT) Rated current/Maximum peak current A 10/20 8/15 Rated voltage/Maximum switching voltage V AC 250/440 250/440 Rated load AC1 VA 2,500 2,000 Rated load AC15 (230 V AC) VA 750 350 Single phase motor rating (230 V AC) kW 0.55 0.37 Breaking capacity DC1: 30/110/220V A 10/0.5/0.15 6/0.5/0.15 Minimum switching load mW (V/mA) 300 (5/5) 300 (5/5) Standard contact material AgNi AgNi Coil specification Nominal voltage (U ) V AC (50/60 Hz) 12 - 24 - 110 - 120 - 230 12 - 24 - 110 - 120 - 230 N V DC 12 - 24 - 125 12 - 24 - 125 Rated power AC/DC VA (50 Hz)/W 1.2/0.5 1.2/0.5 Operating range AC (0.81.1)U (0.81.1)U N N DC (0.731.1)U (0.731.1)U N N Holding voltage AC/DC 0.8 U /0.4 U 0.8 U /0.4 U N N N N Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U /0.1 U N N N N Technical data 6 6 Mechanical life AC/DC cycles 10 10 10 10 3 3 Electrical life at rated load AC1 cycles 100 10 100 10 Operate/release time ms 15/5 (AC) - 15/12 (DC) 10/3 (AC) - 10/10 (DC) Insulation between coil and contacts (1.2/50 s) kV 6 (8 mm) 6 (8 mm) Dielectric strength between open contacts V AC 1,000 1,000 Ambient temperature range C 25+70 25+70 Protection category IP 20 IP 20 Approvals - relay (according to type) 2 X-2013, www.findernet.com