55 Series - General purpose relays 7 - 10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12 - 2 Pole 10 A 55.13 - 3 Pole 10 A 55.14 - 4 Pole 7 A AC coils & DC coils Cadmium Free contacts (preferred version) Contact material options RT III (wash tight) option available 2 pole, 10 A 3 pole, 10 A 4 pole, 7 A PCB mount PCB mount PCB mount 55.12 55.13 55.14 FOR UL HORSEPOWER AND PILOT DUTY RATINGS Copper side view Copper side view Copper side view SEE General technical information page V Contact specification Contact configuration 2 CO (DPDT) 3 CO (3PDT) 4 CO (4PDT) Rated current/Maximum peak current A 10/20 10/20 7/15 Rated voltage/Maximum switching voltage V AC 250/400 250/400 250/250 Rated load AC1 VA 2,500 2,500 1,750 Rated load AC15 (230 V AC) VA 500 500 350 Single phase motor rating (230 V AC) kW 0.37 0.37 0.125 Breaking capacity DC1: 30/110/220V A 10/0.25/0.12 10/0.25/0.12 7/0.25/0.12 Minimum switching load mW (V/mA) 300 (5/5) 300 (5/5) 300 (5/5) Standard contact material AgNi AgNi AgNi Coil specification Nominal voltage (U ) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 N V DC 6 - 12 - 24 - 48 - 60 - 110 -125 - 220 Rated power AC/DC VA (50 Hz)/W 1.5/1 1.5/1 1.5/1 Operating range AC (0.81.1)U (0.81.1)U (0.81.1)U N N N DC (0.81.1)U (0.81.1)U (0.81.1)U N N N Holding voltage AC/DC 0.8 U /0.5 U 0.8 U /0.5 U 0.8 U /0.5 U N N N N N N Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U /0.1 U 0.2 U /0.1 U N N N N N N Technical data 6 6 6 6 6 6 Mechanical life AC/DC cycles 20 10 /50 10 20 10 /50 10 20 10 /50 10 3 3 3 Electrical life at rated load AC1 cycles 200 10 200 10 150 10 Operate/release time ms 9/3 9/3 9/3 Insulation between coil and contacts (1.2/50 s) kV 44 4 Dielectric strength between open contacts V AC 1,000 1,000 1,000 Ambient temperature range C 40+85 40+85 40+85 Environmental protection RT I RT I RT I Approvals (according to type) 155 Series - General purpose relays 7 - 10 A Features 55.32 55.33 55.34 Plug-in mount, general purpose 2, 3 & 4 Pole relays 55.32 - 2 Pole 10 A 55.33 - 3 Pole 10 A 55.34 - 4 Pole 7 A Lockable test button and mechanical flag indicator as standard on 2 & 4 pole types AC coils & DC coils UL Listing (certain relay/socket combinations) Cadmium Free contacts (preferred version) 2 pole, 10 A 3 pole, 10 A 4 pole, 7 A Contact material options Plug-in 94 series sockets Plug-in 94 series sockets Plug-in 94 series sockets 94 series sockets Coil EMC suppression Timer accessories 86 series 55.32 55.33 55.34 FOR UL HORSEPOWER AND PILOT DUTY RATINGS SEE General technical information page V Contact specification Contact configuration 2 CO (DPDT) 3 CO (3PDT) 4 CO (4PDT) Rated current/Maximum peak current A 10/20 10/20 7/15 Rated voltage/Maximum switching voltage V AC 250/400 250/400 250/250 Rated load AC1 VA 2,500 2,500 1,750 Rated load AC15 (230 V AC) VA 500 500 350 Single phase motor rating (230 V AC) kW 0.37 0.37 0.125 Breaking capacity DC1: 30/110/220 V A 10/0.25/0.12 10/0.25/0.12 7/0.25/0.12 Minimum switching load mW (V/mA) 300 (5/5) 300 (5/5) 300 (5/5) Standard contact material AgNi AgNi AgNi Coil specification Nominal voltage (UN) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 V DC 6 - 12 - 24 - 48 - 60 - 110 - 125 - 220 Rated power AC/DC VA (50 Hz)/W 1.5/1 1.5/1 1.5/1 Operating range AC (0.81.1)U (0.81.1)U (0.81.1)U N N N DC (0.81.1)U (0.81.1)U (0.81.1)U N N N Holding voltage AC/DC 0.8 U /0.5 U 0.8 U /0.5 U 0.8 U /0.5 U N N N N N N Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U /0.1 U 0.2 U /0.1 U N N N N N N Technical data 6 6 6 6 6 6 Mechanical life AC/DC cycles 20 10 /50 10 20 10 /50 10 20 10 /50 10 3 3 3 Electrical life at rated load AC1 cycles 200 10 200 10 150 10 Operate/release time ms 9/3 9/3 9/3 Insulation between coil and contacts (1.2/50 s) kV 44 4 Dielectric strength between open contacts V AC 1,000 1,000 1,000 Ambient temperature range C 40+85 40+85 40+85 Environmental protection RT I RT I RT I Approvals (according to type) 2