55
SERIES
55 Series - General purpose relays 7 - 10 A
Features 55.12 55.13 55.14
Printed circuit mount, general purpose
2, 3 & 4 Pole relays
A
55.12 - 2 Pole 10 A
55.13 - 3 Pole 10 A
55.14 - 4 Pole 7 A
AC coils & DC coils
Cadmium Free contacts
Contact material options
RT III (wash tight) option available
2 pole, 10 A 3 pole, 10 A 4 pole, 7 A
PCB mount PCB mount PCB mount
55.12 55.13 55.14
FOR UL RATINGS SEE: Copper side view Copper side view Copper side view
General technical information page V
Contact specification
Contact configuration 2 CO (DPDT) 3 CO (3PDT) 4 CO (4PDT)
Rated current/Maximum peak current A 10/20 10/20 7/15
Rated voltage/Maximum switching voltage V AC 250/400 250/400 250/250
Rated load AC1 VA 2,500 2,500 1,750
Rated load AC15 (230 V AC) VA 500 500 350
Single phase motor rating (230 V AC) kW 0.37 0.37 0.125
Breaking capacity DC1: 30/110/220V A 10/0.25/0.12 10/0.25/0.12 7/0.25/0.12
Minimum switching load mW (V/mA) 300 (5/5) 300 (5/5) 300 (5/5)
Standard contact material AgNi AgNi AgNi
Coil specification
Nominal voltage (U ) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240
N
V DC 6 - 12 - 24 - 48 - 60 - 110 -125 - 220
Rated power AC/DC VA (50 Hz)/W 1.5/1 1.5/1 1.5/1
Operating range AC (0.81.1)U (0.81.1)U (0.81.1)U
N N N
DC (0.81.1)U (0.81.1)U (0.81.1)U
N N N
Holding voltage AC/DC 0.8 U /0.5 U 0.8 U /0.5 U 0.8 U /0.5 U
N N N N N N
Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U /0.1 U 0.2 U /0.1 U
N N N N N N
Technical data
6 6 6 6 6 6
Mechanical life AC/DC cycles 20 10 /50 10 20 10 /50 10 20 10 /50 10
3 3 3
Electrical life at rated load AC1 cycles 200 10 200 10 150 10
Operate/release time ms 10/5 10/5 11/3
Insulation between coil and contacts (1.2/50 s) kV 44 4
Dielectric strength between open contacts V AC 1,000 1,000 1,000
Ambient temperature range C 40+85 40+85 40+85
Environmental protection RT I RT I RT I
Approvals (according to type)
1
II-2014, www.findernet.com55
SERIE S
55 Series - General purpose relays 7 - 10 A
Features 55.32 55.33 55.34
Plug-in mount, general purpose
2, 3 & 4 Pole relays
A
55.32 - 2 Pole 10 A
55.33 - 3 Pole 10 A
55.34 - 4 Pole 7 A
Lockable test button and mechanical flag
indicator as standard on 2 & 4 pole types
AC coils & DC coils
UL Listing (certain relay/socket combinations)
Cadmium Free contacts
2 pole, 10 A 3 pole, 10 A 4 pole, 7 A
Contact material options
Plug-in 94 series sockets Plug-in 94 series sockets Plug-in 94 series sockets
94 series sockets
Coil EMC suppression
Timer accessories 86 series
European Patent
55.32 55.33 55.34
FOR UL RATINGS SEE:
General technical information page V
Contact specification
Contact configuration 2 CO (DPDT) 3 CO (3PDT) 4 CO (4PDT)
Rated current/Maximum peak current A 10/20 10/20 7/15
Rated voltage/Maximum switching voltage V AC 250/400 250/400 250/250
Rated load AC1 VA 2,500 2,500 1,750
Rated load AC15 (230 V AC) VA 500 500 350
Single phase motor rating (230 V AC) kW 0.37 0.37 0.125
Breaking capacity DC1: 30/110/220 V A 10/0.25/0.12 10/0.25/0.12 7/0.25/0.12
Minimum switching load mW (V/mA) 300 (5/5) 300 (5/5) 300 (5/5)
Standard contact material AgNi AgNi AgNi
Coil specification
Nominal voltage (UN) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240
V DC 6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
Rated power AC/DC VA (50 Hz)/W 1.5/1 1.5/1 1.5/1
Operating range AC (0.81.1)U (0.81.1)U (0.81.1)U
N N N
DC (0.81.1)U (0.81.1)U (0.81.1)U
N N N
Holding voltage AC/DC 0.8 U /0.5 U 0.8 U /0.5 U 0.8 U /0.5 U
N N N N N N
Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U /0.1 U 0.2 U /0.1 U
N N N N N N
Technical data
6 6 6 6 6 6
Mechanical life AC/DC cycles 20 10 /50 10 20 10 /50 10 20 10 /50 10
3 3 3
Electrical life at rated load AC1 cycles 200 10 200 10 150 10
Operate/release time ms 10/5 10/5 11/3
Insulation between coil and contacts (1.2/50 s) kV 44 4
Dielectric strength between open contacts V AC 1,000 1,000 1,000
Ambient temperature range C 40+85 40+85 40+85
Environmental protection RT I RT I RT I
Approvals (according to type)
2