56 Series - Miniature power relays 12 A
Features
56.32 56.32-0300 56.34
Plug-in
12 A Power relay, 2 & 4 pole
Flange mount option -
(Faston 187, 4.8x0.5 mm termination)
AC coils & DC coils
Lockable test button and mechanical flag
indicator - standard on 2 pole types
Cadmium Free contacts
(preferred version) 2 pole normally open
2 pole changeover contact 4 pole changeover contact
contact (1.5 mm gap)
Contact material options
Plug-in/Faston 187 Plug-in/Faston 187
Plug-in/Faston 187
96 series sockets, coil EMC suppression,
accessories
1 324 3 4 1 526 3748
56
5 5 9
6 6 10 11 12
78 78 13 14
A1 A2 A1 A2 A1 A2
20.7 27.7
20.7 27.7 41 27.8
10 10 7.25 5.9 8.6 10 10 10
7.25 5.9 4.753.85 7.25 5.9 4.75 3.85
* For 4 CO (4PDT) only.
Contact specification
Contact configuration 2 CO (DPDT) 2 NO (DPST-NO) - 1.5 mm 4 CO (4PDT)
Rated current/Maximum peak current A 12/20 12/20 12/20
Rated voltage/Maximum switching voltage V AC 250/400 250/400 250/400
Rated load AC1 VA 3,000 3,000 3,000
Rated load AC15 (230 V AC) VA 500 500 500
Single phase motor rating (230 V AC) kW 0.55 0.55 0.55
Breaking capacity DC1: 30/110/220 V A 12/0.25/0.12 12/0.6/0.3 12/0.25/0.12
Minimum switching load mW (V/mA) 500 (10/5) 500 (10/5) 500 (10/5)
Standard contact material AgNi AgNi AgNi
Coil specification
Nominal voltage (U ) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*
N
V DC 6-12-24-48-60-110-125-220 6-12-24-48-60-110-125-220
Rated power AC/DC VA (50 Hz)/W 1.5/1 1.5/ 2/1.3
Operating range AC (0.81.1)U (0.851.1)U (0.81.1)U
N N N
DC (0.81.1)U (0.851.1)U
N N
Holding voltage AC/DC 0.8 U /0.6 U 0.85 U / 0.8 U /0.6 U
N N N N N
Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U / 0.2 U /0.1 U
N N N N N
Technical data
6 6 6 6 6
Mechanical life AC/DC cycles 20 10 /50 10 20 10 / 20 10 /50 10
3 3 3
Electrical life at rated load AC1 cycles 200 10 200 10 150 10
Operate/release time ms 8/8 8/4 8/8
Insulation between coil and contacts (1.2/50 s) kV 445
Dielectric strength between open contacts V AC 1,000 2,000 1,000
Ambient temperature range C 40+70 40+70 40+70
Environmental protection RT I RT I RT I
Approvals (according to type)
75
6.5 37.7
6.5 36.3
6.5 35.256 Series - Miniature power relays 12 A
Features
56.42 56.42-0300 56.44
Printed circuit mount
12 A Power relay
2 & 4 pole
AC coils & DC coils
Cadmium Free contacts (preferred version)
Contact material option
27.7
20.7
27.7
2 pole normally open contact
2 pole changeover contact 4 pole changeover contact
(1.5 mm gap)
PCB mount PCB mount
PCB mount
1 324 3 4 1 526 3748
10
14.2
7.25 5.9 4.75 3.85 7.25 5.9 8.6
56.42 56.42-0300
56
5 6 5 6 9 10 11 12
78 78 13 14
A1 A2 A1 A2 A1 A2
41 27.8
41
20.7 20.7
10 10 10
10 10
3.85 3.85
8.6 1 2 3 4
1 2
4.75
4.75
3 4 3 4 5 6 7 8
5.9
5.9 5.9
9 10 11 12
5 6 5 6
7.25
7.25 7.25
10 10 10
7 8 7 8
13 14
7.25 5.9 4.75 3.85
14.2 14.2
56.44
* For 4 CO (4PDT) only Copper side view Copper side view Copper side view
Contact specification
Contact configuration 2 CO (DPDT) 2 NO (DPST-NO) 1.5 mm 4 CO (4PDT)
Rated current/Maximum peak current A 12/20 12/20 12/20
Rated voltage/Maximum switching voltage V AC 250/400 250/400 250/400
Rated load AC1 VA 3,000 3,000 3,000
Rated load AC15 (230 V AC) VA 500 500 500
Single phase motor rating (230 V AC) kW 0.55 0.55 0.55
Breaking capacity DC1: 30/110/220 V A 12/0.25/0.12 12/0.6/0.3 12/0.25/0.12
Minimum switching load mW (V/mA) 500 (10/5) 500 (10/5) 500 (10/5)
Standard contact material AgNi AgNi AgNi
Coil specification
Nominal voltage (U ) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*
N
V DC 6-12-24-48-60-110-125-220 6-12-24-48-60-110-125-220
Rated power AC/DC VA (50 Hz)/W 1.5/1 1.5/ 2/1.3
Operating range AC (0.81.1)U (0.851.1)U (0.81.1)U
N N N
DC (0.81.1)U (0.851.1)U
N N
Holding voltage AC/DC 0.8 U /0.6 U 0.85 U / 0.8 U /0.6 U
N N N N N
Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U/ 0.2 U /0.1 U
N N N N N
Technical data
6 6 6 6 6
Mechanical life AC/DC cycles 20 10 /50 10 20 10 / 20 10 /50 10
3 3 3
Electrical life at rated load AC1 cycles 200 10 200 10 150 10
Operate/release time ms 8/8 8/4 8/8
Insulation between coil and contacts (1.2/50 s) kV 445
Dielectric strength between open contacts V AC 1,000 2,000 1,000
Ambient temperature range C 40+70 40+70 40+70
Environmental protection RT I RT I RT I
Approvals (according to type)
76
6.5 37.7
6.5 35.2
6.5 36.3
27.7
2.5
27.7
2.5
27.6
2.5