58 SERIES 58 Series - Relay interface modules 7 - 10 A Features 58.32 58.33 58.34 2, 3 & 4 Pole relay interface modules, 27 mm wide. Ideal interface for PLC and electronic systems 58.32 - 2 Pole 10 A (screw terminals) 58.33 - 3 Pole 10 A (screw terminals) 58.34 - 4 Pole 7 A (screw terminals) B AC coils and DC coils Supply status indication and coil suppression module as standard 2 pole, 10 A 3 pole, 10 A 4 pole, 7 A Identification label Screw terminals Screw terminals Screw terminals Cadmium Free contacts 35 mm rail (EN 60715) 35 mm rail (EN 60715) 35 mm rail (EN 60715) mounting mounting UL Listing (certain relay/socket combinations) mounting 35 mm rail (EN 60715) mounting 58.32 / 58.33 / 58.34 Screw terminals For outline drawing see page 5 Example: AC Example: DC Example: AC Contact specification Contact configuration 2 CO (DPDT) 3 CO (3PDT) 4 CO (4PDT) Rated current/Maximum peak current A 10/20 10/20 7/15 Rated voltage/Maximum switching voltage V AC 250/400 250/400 250/250 Rated load AC1 VA 2,500 2,500 1,750 Rated load AC15 (230 V AC) VA 500 500 350 Single phase motor rating (230 V AC) kW 0.37 0.37 0.125 Breaking capacity DC1: 30/110/220V A 10/0.25/0.12 10/0.25/0.12 7/0.25/0.12 Minimum switching load mW (V/mA) 300 (5/5) 300 (5/5) 300 (5/5) Standard contact material AgNi AgNi AgNi Coil specification Nominal voltage (U ) V AC (50/60 Hz) 12 - 24 - 48 - 110 - 120 - 230 12 - 24 - 48 - 110 - 120 - 230 12 - 24 - 48 - 110 - 120 - 230 N V DC 12 - 24 - 48 - 125 12 - 24 - 48 - 125 12 - 24 - 48 - 125 Rated power AC/DC VA (50 Hz)/W 1.5/1 1.5/1 1.5/1 Operating range AC (0.81.1)U (0.81.1)U (0.81.1)U N N N DC (0.81.1)U (0.81.1)U (0.81.1)U N N N Holding voltage AC/DC 0.8 U /0.5 U 0.8 U /0.5 U 0.8 U /0.5 U N N N N N N Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U /0.1 U 0.2 U /0.1 U N N N N N N Technical data 6 6 6 6 6 6 Mechanical life AC/DC cycles 20 10 /50 10 20 10 /50 10 20 10 /50 10 3 3 3 Electrical life at rated load AC1 cycles 200 10 200 10 150 10 Operate/release time ms 10/5 (AC) - 10/15 (DC) 10/5 (AC) - 10/15 (DC) 11/3 (AC) - 11/15 (DC) Insulation between coil and contacts (1.2/50 s) kV 3.6 3.6 3.6 Dielectric strength between open contacts V AC 1,000 1,000 1,000 Ambient temperature range C 40+70 40+70 40+70 Protection category IP 20 IP 20 IP 20 Approvals relay (according to type) 1 IX-2014, www.findernet.com58 SERIE S 58 Series - Relay interface modules 7 - 10 A Features 58.54 4 Pole relay interface modules, 31 mm wide. Ideal interface for PLC and electronic systems 58.54 - 4 Pole 7 A (screwless terminals) AC coils and DC coils Supply status indication and coil suppression module as standard B Identification label Cadmium Free contacts 4 pole, 7 A 35 mm rail (EN 60715) mounting Screwless terminals 58.54 35 mm rail (EN 60715) Screwless terminal mounting For outline drawing see page 5 Example: AC Contact specification Contact configuration 4 CO (4PDT) Rated current/Maximum peak current A 7/15 Rated voltage/Maximum switching voltage V AC 250/250 Rated load AC1 VA 1,750 Rated load AC15 (230 V AC) VA 350 Single phase motor rating (230 V AC) kW 0.125 Breaking capacity DC1: 30/110/220V A 7/0.25/0.12 Minimum switching load mW (V/mA) 300 (5/5) Standard contact material AgNi Coil specification Nominal voltage (U ) V AC (50/60 Hz) 12 - 24 - 48 - 110 - 120 - 230 N V DC 12 - 24 - 48 - 125 Rated power AC/DC VA (50 Hz)/W 1.5/1 Operating range AC (0.81.1)U N DC (0.81.1)U N Holding voltage AC/DC 0.8 U /0.5 U N N Must drop-out voltage AC/DC 0.2 U /0.1 U N N Technical data 6 6 Mechanical life AC/DC cycles 20 10 /50 10 3 Electrical life at rated load AC1 cycles 150 10 Operate/release time ms 11/3 (AC) - 11/15 (DC) Insulation between coil and contacts (1.2/50 s) kV 3.6 Dielectric strength between open contacts V AC 1,000 Ambient temperature range C 25+70 Protection category IP 20 Approvals relay (according to type) 2 IX-2014, www.findernet.com