60 Series - General purpose relays 6 - 10 A Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations) Contact material options Lockable test button with mechanical flag indicator (preferred version) 90 series sockets 2 pole, 10 A power contacts 3 pole, 10 A power contacts Coil EMC suppression 8 pin plug-in 11 pin plug-in Timer accessories 86 series FOR UL HORSEPOWER AND PILOT DUTY RATINGS SEE General technical information page V Contact specification Contact configuration 2 CO (DPDT) 3 CO (3PDT) Rated current/Maximum peak current A 10/20 10/20 Rated voltage/Maximum switching voltage V AC 250/400 250/400 Rated load AC1 VA 2,500 2,500 Rated load AC15 (230 V AC) VA 500 500 Single phase motor rating (230 V AC) kW 0.37 0.37 Breaking capacity DC1: 30/110/220 V A 10/0.4/0.15 10/0.4/0.15 Minimum switching load mW (V/mA) 500 (10/5) 500 (10/5) Standard contact material AgNi AgNi Coil specification Nominal voltage (U ) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400 N V DC 6 - 12 - 24 - 48 - 60 - 110 -125 - 220 Rated power AC/DC VA (50 Hz)/W 2.2/1.3 2.2/1.3 Operating range AC (0.81.1)U (0.81.1)U N N DC (0.81.1)U (0.81.1)U N N Holding voltage AC/DC 0.8 U /0.5 U 0.8 U /0.5 U N N N N Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U /0.1 U N N N N Technical data 6 6 6 6 Mechanical life AC/DC cycles 20 10 /50 10 20 10 /50 10 3 3 Electrical life at rated load AC1 cycles 200 10 200 10 Operate/release time ms 9/9 9/9 Insulation between coil and contacts (1.2/50 s) kV 43.6 Dielectric strength between open contacts V AC 1,000 1,000 Ambient temperature range C 40+70 40+70 Environmental protection RT I RT I Approvals (according to type) 160 Series - General purpose relays 6 - 10 A Features 60.12 - 5200 60.13 - 5200 Plug-in mount - 6 A Bifurcated contacts for low level switching 2 & 3 pole changeover contacts Cadmium Free contacts (Gold plated Silver Nickel) AC coils & DC coils Lockable test button with mechanical flag indicator (preferred version) 90 series sockets Coil EMC suppression 3 pole, 6 A bifurcated contacts 2 pole, 6 A bifurcated contacts Timer accessories 86 series 8 pin plug-in 11 pin plug-in FOR UL HORSEPOWER AND PILOT DUTY RATINGS SEE General technical information page V Contact specification Contact configuration 2 CO (DPDT) 3 CO (3PDT) Rated current/Maximum peak current A 6/10 6/10 Rated voltage/Maximum switching voltage V AC 250/400 250/400 Rated load AC1 VA 1,500 1,500 Rated load AC15 (230 V AC) VA 250 250 Single phase motor rating (230 V AC) kW 0.185 0.185 Breaking capacity DC1: 30/110/220 V A 6/0.3/0.12 6/0.3/0.12 Minimum switching load mW (V/mA) 50 (5/5) 50 (5/5) Standard contact material AgNi + Au (5 m) bifurcated contacts AgNi + Au (5 m) bifurcated contacts Coil specification Nominal voltage (U ) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400 N V DC 6 - 12 - 24 - 48 - 60 - 110 -125 - 220 Rated power AC/DC VA (50 Hz)/W 2.2/1.3 2.2/1.3 Operating range AC (0.81.1)U (0.81.1)U N N DC (0.81.1)U (0.81.1)U N N Holding voltage AC/DC 0.8 U /0.5 U 0.8 U /0.5 U N N N N Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U /0.1 U N N N N Technical data 6 6 6 6 Mechanical life AC/DC cycles 20 10 /50 10 20 10 /50 10 3 3 Electrical life at rated load AC1 cycles 250 10 250 10 Operate/release time ms 9/9 9/9 Insulation between coil and contacts (1.2/50 s) kV 43.6 Dielectric strength between open contacts V AC 1,000 1,000 Ambient temperature range C 40+70 40+70 Environmental protection RT I RT I Approvals (according to type) 2