66 Series - Power relays 30 A
Features 66.22 66.82 66.82-xx07
2 Pole Changeover (DPDT)
30 A Power relay
66.22 PCB connections & mount
66.82 Faston 250 connections
- Flange mount
66.82-xx07 Faston 250 connections
- 35 mm rail mount
Reinforced insulation between coil and
contacts according to EN 60335-1;
30 A rated contacts 30 A rated contacts 30 A rated contacts
8 mm creepage and clearance distances
PCB mount - Flange mount 35 mm rail mount
AC coils & DC coils
bifurcated terminals Faston 250 connections Faston 250 connections
Cadmium Free option available
51.5 33.5
12 14 22 24 12 14 22 24
12 14 22 24
3 2 76 3 2 76 3 2 76
11 21
11 21 11 21
4 8
0.8 4 8 4 8
1.2 0.8 1.2
5.2 5.2
0 A1 A2 1
0 A1 A2 1 0 A1 A2 1
3.5
66.22
51.5 5
26 7.5 7.5
3.5
35
5.2 23.4 7.5 7.5
33.5
22 21 24
1
A2
7 8 6
1
22 21 24
A2
7 8 6 3 4 2
A1
0
12 11 14
A1
3 4 2
0
51.5
12 11 14
59.5
0.8
6.3 16
51.5
68.5
66.82-xxxx
6.3 0.8
FOR UL HORSEPOWER AND PILOT DUTY RATINGS Copper side view
SEE General technical information page V
Contact specification
Contact configuration 2 CO (DPDT) 2 CO (DPDT) 2 CO (DPDT)
Rated current/Maximum peak current A 30/50 (NO) - 10/20 (NC) 30/50 (NO) - 10/20 (NC) 30/50 (NO) - 10/20 (NC)
Rated voltage/Maximum switching voltage V AC 250/440 250/440 250/440
Rated load AC1 VA 7,500 (NO) - 2,500 (NC) 7,500 (NO) - 2,500 (NC) 7,500 (NO) - 2,500 (NC)
Rated load AC15 (230 V AC) VA 1,200 (NO) 1,200 (NO) 1,200 (NO)
Single phase motor rating (230 V AC) kW 1.5 (NO) 1.5 (NO) 1.5 (NO)
Breaking capacity DC1: 30/110/220 V A 25/0.7/0.3 (NO) 25/0.7/0.3 (NO) 25/0.7/0.3 (NO)
Minimum switching load mW (V/mA) 1,000 (10/10) 1,000 (10/10) 1,000 (10/10)
Standard contact material AgCdO AgCdO AgCdO
Coil specification
Nominal voltage (U ) V AC (50/60 Hz) 6 - 12 - 24 - 110/115 - 120/125 - 230 - 240
N
V DC 6 - 12 - 24 - 110 - 125
Rated power AC/DC VA (50 Hz)/W 3.6/1.7 3.6/1.7 3.6/1.7
Operating range AC (0.81.1)U (0.81.1)U (0.81.1)U
N N N
DC (0.81.1)U (0.81.1)U (0.81.1)U
N N N
Holding voltage AC/DC 0.8 U /0.5 U 0.8 U /0.5 U 0.8 U /0.5 U
N N N N N N
Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U /0.1 U 0.2 U /0.1 U
N N N N N N
Technical data
6 6 6
Mechanical life AC/DC cycles 10 10 10 10 10 10
3 3 3
Electrical life at rated load AC1 cycles 100 10 100 10 100 10
Operate/release time ms 8/15 8/15 8/15
Insulation between coil and contacts (1.2/50 s) kV 6 (8 mm) 6 (8 mm) 6 (8 mm)
Dielectric strength between open contacts V AC 1,500 1,500 1,500
Ambient temperature range C 40+70 40+70 40+70
Environmental protection RT II RT II RT II
Approvals (according to type)
1
9.8 31
4 31
3
33.5
25.4
5.2 10.8 5.2
4.5
15
9.8 31 8
5.566 Series - Power relays 30 A
Features 66.22-x300 66.82-x300 66.82-x307
2 Pole NO (DPST-NO)
30 A Power relay
66.22-x300 PCB mount
66.82-x300 Faston 250 connections
- Flange mount
66.82-x307 Faston 250 connections
- 35 mm rail mount
Reinforced insulation between coil and
contacts according to EN 60335-1;
30 A rated contacts 30 A rated contacts 30 A rated contacts
8 mm creepage and clearance distances
PCB mount - Flange mount 35 mm rail mount
AC coils & DC coils
bifurcated terminals Faston 250 connections Faston 250 connections
Cadmium Free option available
51.5 33.5
14 24 14 24 14 24
2 6
2 6 2 6
11 21
11 21 11 21
4 8
1.2 0.8 1.2 0.8
4 8 4 8
5.2 5.2
0 A1 A2 1
0 A1 A2 1 0 A1 A2 1
3.5
66.22-0300
51.5 5
33.5 7.5
3.5
33.5 35
5.2 30.9 7.5
21 24
1
A2
8 6
1
21 24
A2
4 2
8 6
A1
0
11 14
A1
4 2
0
11 14 51.5
59.5
0.8
6.3 16
51.5
68.5
66.82-0300
6.3 0.8
FOR UL HORSEPOWER AND PILOT DUTY RATINGS Copper side view
SEE General technical information page V
Contact specification
Contact configuration 2 NO (DPST-NO) 2 NO (DPST-NO) 2 NO (DPST-NO)
Rated current/Maximum peak current A 30/50 30/50 30/50
Rated voltage/Maximum switching voltage V AC 250/440 250/440 250/440
Rated load AC1 VA 7,500 7,500 7,500
Rated load AC15 (230 V AC) VA 1,200 1,200 1,200
Single phase motor rating (230 V AC) kW 1.5 1.5 1.5
Breaking capacity DC1: 30/110/220 V A 25/0.7/0.3 25/0.7/0.3 25/0.7/0.3
Minimum switching load mW (V/mA) 1,000 (10/10) 1,000 (10/10) 1,000 (10/10)
Standard contact material AgCdO AgCdO AgCdO
Coil specification
Nominal voltage (U ) V AC (50/60 Hz) 6 - 12 - 24 - 110/115 - 120/125 - 230 - 240
N
V DC 6 - 12 - 24 - 110 -125
Rated power AC/DC VA (50 Hz)/W 3.6/1.7 3.6/1.7 3.6/1.7
Operating range AC (0.81.1)U (0.81.1)U (0.81.1)U
N N N
DC (0.81.1)U (0.81.1)U (0.81.1)U
N N N
Holding voltage AC/DC 0.8 U /0.5 U 0.8 U /0.5 U 0.8 U /0.5 U
N N N N N N
Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U /0.1 U 0.2 U /0.1 U
N N N N N N
Technical data
6 6 6
Mechanical life AC/DC cycles 10 10 10 10 10 10
3 3 3
Electrical life at rated load AC1 cycles 100 10 100 10 100 10
Operate/release time ms 8/10 8/10 8/10
Insulation between coil and contacts (1.2/50 s) kV 6 (8 mm) 6 (8 mm) 6 (8 mm)
Dielectric strength between open contacts V AC 1,500 1,500 1,500
Ambient temperature range C 40+70 40+70 40+70
Environmental protection RT II RT II RT II
Approvals (according to type)
2
4 31
9.75 31
3
33.5
25.4
5.2 10.8 5.2
4.5
15
9.8 31 8
5.5