66 Series - Power relays 30 A Features 66.22 66.82 66.82-xx07 2 Pole Changeover (DPDT) 30 A Power relay 66.22 PCB connections & mount 66.82 Faston 250 connections - Flange mount 66.82-xx07 Faston 250 connections - 35 mm rail mount Reinforced insulation between coil and contacts according to EN 60335-1 30 A rated contacts 30 A rated contacts 30 A rated contacts 8 mm creepage and clearance distances PCB mount - Flange mount 35 mm rail mount AC coils & DC coils bifurcated terminals Faston 250 connections Faston 250 connections Cadmium Free option available 51.5 33.5 12 14 22 24 12 14 22 24 12 14 22 24 3 2 76 3 2 76 3 2 76 11 21 11 21 11 21 4 8 0.8 4 8 4 8 1.2 0.8 1.2 5.2 5.2 0 A1 A2 1 0 A1 A2 1 0 A1 A2 1 3.5 66.22 51.5 5 26 7.5 7.5 3.5 35 5.2 23.4 7.5 7.5 33.5 22 21 24 1 A2 7 8 6 1 22 21 24 A2 7 8 6 3 4 2 A1 0 12 11 14 A1 3 4 2 0 51.5 12 11 14 59.5 0.8 6.3 16 51.5 68.5 66.82-xxxx 6.3 0.8 FOR UL HORSEPOWER AND PILOT DUTY RATINGS Copper side view SEE General technical information page V Contact specification Contact configuration 2 CO (DPDT) 2 CO (DPDT) 2 CO (DPDT) Rated current/Maximum peak current A 30/50 (NO) - 10/20 (NC) 30/50 (NO) - 10/20 (NC) 30/50 (NO) - 10/20 (NC) Rated voltage/Maximum switching voltage V AC 250/440 250/440 250/440 Rated load AC1 VA 7,500 (NO) - 2,500 (NC) 7,500 (NO) - 2,500 (NC) 7,500 (NO) - 2,500 (NC) Rated load AC15 (230 V AC) VA 1,200 (NO) 1,200 (NO) 1,200 (NO) Single phase motor rating (230 V AC) kW 1.5 (NO) 1.5 (NO) 1.5 (NO) Breaking capacity DC1: 30/110/220 V A 25/0.7/0.3 (NO) 25/0.7/0.3 (NO) 25/0.7/0.3 (NO) Minimum switching load mW (V/mA) 1,000 (10/10) 1,000 (10/10) 1,000 (10/10) Standard contact material AgCdO AgCdO AgCdO Coil specification Nominal voltage (U ) V AC (50/60 Hz) 6 - 12 - 24 - 110/115 - 120/125 - 230 - 240 N V DC 6 - 12 - 24 - 110 - 125 Rated power AC/DC VA (50 Hz)/W 3.6/1.7 3.6/1.7 3.6/1.7 Operating range AC (0.81.1)U (0.81.1)U (0.81.1)U N N N DC (0.81.1)U (0.81.1)U (0.81.1)U N N N Holding voltage AC/DC 0.8 U /0.5 U 0.8 U /0.5 U 0.8 U /0.5 U N N N N N N Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U /0.1 U 0.2 U /0.1 U N N N N N N Technical data 6 6 6 Mechanical life AC/DC cycles 10 10 10 10 10 10 3 3 3 Electrical life at rated load AC1 cycles 100 10 100 10 100 10 Operate/release time ms 8/15 8/15 8/15 Insulation between coil and contacts (1.2/50 s) kV 6 (8 mm) 6 (8 mm) 6 (8 mm) Dielectric strength between open contacts V AC 1,500 1,500 1,500 Ambient temperature range C 40+70 40+70 40+70 Environmental protection RT II RT II RT II Approvals (according to type) 1 9.8 31 4 31 3 33.5 25.4 5.2 10.8 5.2 4.5 15 9.8 31 8 5.566 Series - Power relays 30 A Features 66.22-x300 66.82-x300 66.82-x307 2 Pole NO (DPST-NO) 30 A Power relay 66.22-x300 PCB mount 66.82-x300 Faston 250 connections - Flange mount 66.82-x307 Faston 250 connections - 35 mm rail mount Reinforced insulation between coil and contacts according to EN 60335-1 30 A rated contacts 30 A rated contacts 30 A rated contacts 8 mm creepage and clearance distances PCB mount - Flange mount 35 mm rail mount AC coils & DC coils bifurcated terminals Faston 250 connections Faston 250 connections Cadmium Free option available 51.5 33.5 14 24 14 24 14 24 2 6 2 6 2 6 11 21 11 21 11 21 4 8 1.2 0.8 1.2 0.8 4 8 4 8 5.2 5.2 0 A1 A2 1 0 A1 A2 1 0 A1 A2 1 3.5 66.22-0300 51.5 5 33.5 7.5 3.5 33.5 35 5.2 30.9 7.5 21 24 1 A2 8 6 1 21 24 A2 4 2 8 6 A1 0 11 14 A1 4 2 0 11 14 51.5 59.5 0.8 6.3 16 51.5 68.5 66.82-0300 6.3 0.8 FOR UL HORSEPOWER AND PILOT DUTY RATINGS Copper side view SEE General technical information page V Contact specification Contact configuration 2 NO (DPST-NO) 2 NO (DPST-NO) 2 NO (DPST-NO) Rated current/Maximum peak current A 30/50 30/50 30/50 Rated voltage/Maximum switching voltage V AC 250/440 250/440 250/440 Rated load AC1 VA 7,500 7,500 7,500 Rated load AC15 (230 V AC) VA 1,200 1,200 1,200 Single phase motor rating (230 V AC) kW 1.5 1.5 1.5 Breaking capacity DC1: 30/110/220 V A 25/0.7/0.3 25/0.7/0.3 25/0.7/0.3 Minimum switching load mW (V/mA) 1,000 (10/10) 1,000 (10/10) 1,000 (10/10) Standard contact material AgCdO AgCdO AgCdO Coil specification Nominal voltage (U ) V AC (50/60 Hz) 6 - 12 - 24 - 110/115 - 120/125 - 230 - 240 N V DC 6 - 12 - 24 - 110 -125 Rated power AC/DC VA (50 Hz)/W 3.6/1.7 3.6/1.7 3.6/1.7 Operating range AC (0.81.1)U (0.81.1)U (0.81.1)U N N N DC (0.81.1)U (0.81.1)U (0.81.1)U N N N Holding voltage AC/DC 0.8 U /0.5 U 0.8 U /0.5 U 0.8 U /0.5 U N N N N N N Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U /0.1 U 0.2 U /0.1 U N N N N N N Technical data 6 6 6 Mechanical life AC/DC cycles 10 10 10 10 10 10 3 3 3 Electrical life at rated load AC1 cycles 100 10 100 10 100 10 Operate/release time ms 8/10 8/10 8/10 Insulation between coil and contacts (1.2/50 s) kV 6 (8 mm) 6 (8 mm) 6 (8 mm) Dielectric strength between open contacts V AC 1,500 1,500 1,500 Ambient temperature range C 40+70 40+70 40+70 Environmental protection RT II RT II RT II Approvals (according to type) 2 4 31 9.75 31 3 33.5 25.4 5.2 10.8 5.2 4.5 15 9.8 31 8 5.5