ENGLISH 80.11.0.240.0000 LED U 2 N 80.21.0.240.0000 80.11 - 80.21 - 80.41 80.41.0.240.0000 15 - 18 15 - 16 MODULAR TIMER, MONO-FUNCTION 80.11/21 80.41 U (24...240)V AC (50/60 Hz)/DC N 15 - 18 15 - 16 U 16.8 V AC/DC min FRONT VIEW 1 U 265 V AC/DC max 15 - 16 A Time scales rotary selector P <1.8 VA (50 Hz) / <1 W (AC/DC) B Time setting 15 - 16 15 - 18 C LED 1 CO (SPDT) 16A 250V AC TIME SCALES 2 AC1 4000 VA 3a AC15 (230 V AC) 750 VA 3 PI PE 3 WIRING DIAGRAM AND FUNCTIONS (80.11-80.21) M (230 V AC) 0.55 kW 3a Start via contact in supply line (A1) 80.11 80.11 AI = On-delay DC1 (30/110/220) V (16/0.3/0.12) A 80.21 DI = Interval (10...+50)C 4 WIRING DIAGRAM AND FUNCTION (80.41) PI PE 4a With signal START function IP20 Start via contact into control terminal (B1) 80.21 BE = Off-delay with control signal 4b Possible to control an external load, such as another relay coil 80.11 1 or timer, connected to the signal start terminal B1 80.41 80.21 4c With DC supply, positive polarity has to be connected to B1 4a 4 terminal (according to EN 60204-1)PI PE 4d A voltage other than the supply voltage can be applied to the command Start (B1), example: 80.41 A1-A2 = 230 V AC A B1-A2 = 24 V DC B 4b 4c 4d C OTHER DATA Minimum control impulse: 50 ms (80.41) Recovery time: 100 ms 88.8 mm 35 mm rail mount (EN 60715) 60.8 mm WORKING CONDITIONS In conformity with the European Directive on EMC 2014/30/EC, 17.5 mm the timer relay has a level of immunity, against radiated and conducted disturbances, considerably higher than requirements of EN 61812-1 standard. However, devices like transformers, motors, contactors, switches and Open Type Device power cables may cause disturbances and even damage the timer Pollution degree 2 Installation Environment Maximum Surrounding Air Temperature 40C electronic circuit. For that reason, the wiring cables must be as short 2 2 (1x4/2x2.5) mm (1x6/2x4) mm Use 60/75C copper (Cu) conductor only and as possible, and, when necessary, the timer shall be protected by the (1x12/2x14) AWG (1x10/2x12) AWG 0.8 Nm wire ranges No. 1418 AWG, stranded or solid relevant RC network, varistor or surge voltage protector. Terminal tightening torque of 7.1 Ib.in. (0.8 Nm) Utility Model - IB8011001 - 02/18 - FINDER S.p.A. - 10040 ALMESE (TO) - ITALYX-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for Timers category: Click to view products by Finder manufacturer: Other Similar products are found below : 79237785 H3DS-GL AC24-230/DC24-48 H5AN-4DM DC12-24 H5CN-XDNM AC100-240 H5CN-YAN AC100-240 H5CX-L8S-N AC100- 240 H3AMNSCAC100240 H3AM-NSR-B AC100-240 H3CA-8 DC12 H3CR-A8-302 DC24 H3CR-F AC24-48/DC12-48 H3CR-G8EL AC200-240 H5AN-4D DC12-24 81506944 88225029 H5S-YB4-X H3CR-A-301 AC100-240/DC100-125 H3CR-AS AC24-48/DC12-48 H3DK-GE AC240-440 H3RN-2 AC24 H3RN-21 AC24 H3CR-H8RL AC/DC24 M H3CR-H8RL AC100-120 S H3CR-G8EL-31 AC100-120 H3CR-H8RL AC100-120 M H3CR-HRL AC100-120 M H3CR-A8-301 AC24-48/DC12-48 H3CR-H8RL AC/DC24 S H7AN-2D DC12-24 H5CN-XANS DC12-48 H3CA-8 DC110 H7AN-W4DM DC12-24 H7AN-4DM DC12-24 H7AN-4D DC12-24 H7AN-RT6M AC100-240 H3CA-8H AC200/220/240 MTR17-BA-U240-116 PM4HSDM-S-AC240VS PM4HSDM-S-AC240VSW PO-405 600DT-CU H3Y-2-B DC24 30S PM4HF8-M-DC24V PM4HS-H-DC12VSW H3Y-2-B AC100-120 10S H3Y-2-B AC100-120 30S H3C-R H3CR-A8-301 24-48AC/12- 48DC H3CR-A8E 24-48AC/DC H3CR-F8 100-240AC/100-125DC