80 SERIES 80 Series - Modular timers 16 A Features 80.01 80.11 Multi-function and mono-function timer range 80.01 - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h High input/output isolation 35 mm rail (EN 60715) mount Blade + cross - both flat blade and cross head screw drivers can be used to adjust the range and function selectors, the timing trimmer, and Multi-voltage Multi-voltage to disengage the rail mounting clip Multi-function Mono-function New multi-voltage versions with PWM clever technology AI: On-delay AI: On-delay DI: Interval 80.01 / 80.11 SW: Symmetrical flasher (starting pulse on) Screw terminal BE: Off-delay with control signal CE: On- and off-delay with control signal DE: Interval with control signal on FOR UL RATINGS SEE: General technical information page V Wiring diagram Wiring diagram Wiring diagram For outline drawing see page 6 (without control signal) (with control signal) (without control signal) Contact specification Contact configuration 1 CO (SPDT) 1 CO (SPDT) H Rated current/Maximum peak current A 16/30 16/30 Rated voltage/Maximum switching voltage V AC 250/400 250/400 Rated load AC1 VA 4,000 4,000 Rated load AC15 (230 V AC) VA 750 750 Single phase motor rating (230 V AC) kW 0.55 0.55 Breaking capacity DC1: 30/110/220 V A 16/0.3/0.12 16/0.3/0.12 Minimum switching load mW (V/mA) 500 (10/5) 500 (10/5) Standard contact material AgCdO AgCdO Supply specification Nominal voltage (U ) V AC (50/60 Hz) 12240 24...240 N V DC 12240 24...240 Rated power AC/DC VA (50 Hz)/W < 1.8 / < 1 < 1.8 / < 1 Operating range V AC 10.8...265 16.8...265 V DC 10.8...265 16.8...265 Technical data Specified time range (0.12)s, (120)s, (0.12)min, (120)min, (0.12)h, (124)h Repeatability % 1 1 Recovery time ms 100 100 Minimum control impulse ms 50 Setting accuracy-full range % 5 5 3 3 Electrical life at rated load in AC1 cycles 10010 10010 Ambient temperature range C 10+50 10+50 Protection category IP 20 IP 20 Approvals (according to type) 1 I-2015, www.findernet.com80 SERIE S 80 Series - Modular timers 16 A Features 80.21 80.41 80.91 Mono-function timer range 80.21 - Interval, multi-voltage 80.41 - Off-delay with control signal, multi-voltage 80.91 - Asymmetrical flasher, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h High input/output isolation 35 mm rail (EN 60715) mount Blade + cross - both flat blade and cross head Multi-voltage Multi-voltage screw drivers can be used to adjust the range Multi-voltage Mono-function Mono-function Mono-function and function selectors, the timing trimmer, and to disengage the rail mounting clip New multi-voltage versions with PWM clever DI: Interval BE: Off-delay with control signal LI: Asymmetrical flasher (starting pulse on) technology LE: Asymmetrical flasher (starting pulse on) with control signal 80.21 / 80.41 / 80.91 Screw terminal FOR UL RATINGS SEE: General technical information page V Wiring diagram Wiring diagram (without control (with control Wiring diagram Wiring diagram signal) signal) For outline drawing see page 6 (without control signal) (with control signal) Contact specification Contact configuration 1 CO (SPDT) 1 CO (SPDT) 1 CO (SPDT) H Rated current/Maximum peak current A 16/30 16/30 16/30 Rated voltage/Maximum switching voltage V AC 250/400 250/400 250/400 Rated load AC1 VA 4,000 4,000 4,000 Rated load AC15 (230 V AC) VA 750 750 750 Single phase motor rating (230 V AC) kW 0.55 0.55 0.55 Breaking capacity DC1: 30/110/220 V A 16/0.3/0.12 16/0.3/0.12 16/0.3/0.12 Minimum switching load mW (V/mA) 500 (10/5) 500 (10/5) 500 (10/5) Standard contact material AgCdO AgCdO AgCdO Supply specification Nominal voltage (U ) V AC (50/60 Hz) 24...240 24...240 12...240 N V DC 24...240 24...240 12...240 Rated power AC/DC VA (50 Hz)/W < 1.8 / < 1 < 1.8 / < 1 < 1.8 / < 1 Operating range V AC 16.8...265 16.8...265 10.8...265 V DC 16.8...265 16.8...265 10.8...265 Technical data Specified time range (0.12)s, (120)s, (0.12)min, (120)min, (0.12)h, (124)h Repeatability % 1 1 1 Recovery time ms 100 100 100 Minimum control impulse ms 50 50 Setting accuracy-full range % 5 5 5 3 3 3 Electrical life at rated load in AC1 cycles 10010 10010 10010 Ambient temperature range C 10+50 10+50 10+50 Protection category IP 20 IP 20 IP 20 Approvals (according to type) 2 I-2015, www.findernet.com