85 Series - Miniature plug-in timers 7 - 10 A Features 85.02 85.03 85.04 Plug-in timer 85.02 - 2 Pole 10 A 85.03 - 3 Pole 10 A 85.04 - 4 Pole 7 A Multifunctions Seven time scales, from 0.05s to 100h 94 series sockets 2 pole, 10 A 3 pole, 10 A 4 pole, 7 A AC/DC supply non polarized AC/DC supply non polarized AC/DC supply non polarized Plug-in for use with 94 series Plug-in for use with 94 series Plug-in for use with 94 series sockets sockets sockets AI: On-delay AI: On-delay AI: On-delay DI: Interval DI: Interval DI: Interval SW: Symmetrical flasher SW: Symmetrical flasher SW: Symmetrical flasher (starting pulse on) (starting pulse on) (starting pulse on) GI: Pulse delayed GI: Pulse delayed GI: Pulse delayed FOR UL RATINGS SEE: Wiring diagram Wiring diagram Wiring diagram General technical information page V (without control signal) (without control signal) (without control signal) Contact specification Contact configuration 2 CO (DPDT) 3 CO (3PDT) 4 CO (4PDT) Rated current/Maximum peak current A 10/20 10/20 7/15 Rated voltage/Maximum switching voltage V AC 250/400 250/400 250/250 Rated load AC1 VA 2,500 2,500 1,750 Rated load AC15 (230 V AC) VA 500 500 350 Single phase motor rating (230 V AC) kW 0.37 0.37 0.125 Breaking capacity DC1: 30/110/220 V A 10/0.25/0.12 10/0.25/0.12 7/0.25/0.12 Minimum switching load mW (V/mA) 300 (5/5) 300 (5/5) 300 (5/5) Standard contact material AgNi AgNi AgNi Supply specification Nominal voltage (U ) V AC (50/60 Hz) 230240 230240 230240 N V AC/DC 12 - 24 - 48 - 110125 (non polarized) Rated power AC/DC V AC (50 Hz)/W 2/2 2/2 2/2 Operating range AC (0.851.1)U (0.851.1)U (0.851.1)U N N N DC (0.851.1)U (0.851.1)U (0.851.1)U N N N Technical data Specified time range (0.051)s, (0.510)s, (5100)s, (0.510)min, (5100)min, (0.510)h, (5100)h Repeatability % 2 2 2 Recovery time ms 20 20 20 Minimum control impulse ms Setting accuracy-full range % 5 5 5 3 3 3 Electrical life at rated load in AC1 cycles 200 10 200 10 150 10 Ambient temperature range C 20+60 20+60 20+60 Protection category IP 40 IP 40 IP 40 Approvals (according to type) 185 Series - Miniature plug-in timers 7 - 10 A Ordering information Example: 85 series timer, 4 CO (4PDT), 24 V AC/DC supply voltage, AI, DI, GI, SW functions. 85..0 4 0.02 4. 0 0 0 0 Series Supply voltage 012 = 12 V AC/DC Type 024 = 24 V AC/DC 0 = Multifunction (AI, DI, GI, SW)* 048 = 48 V AC/DC * AI = On-delay 125 = (110125)V AC/DC DI = Interval 240 = (230240)V AC GI = Pulse delayed SW = Symmetrical flasher (starting pulse on) Supply version 0 = AC (50/60 Hz)/DC No. of poles 8 = AC (50/60 Hz) for 240 V only 2 = 2 pole - 10 A 3 = 3 pole - 10 A 4 = 4 pole - 7 A Technical data Insulation Dielectric strength 85.02, 85.03 85.04 between input and output circuit V AC 2,000 2,000 between open contacts V AC 1,000 1,000 between adjacent contacts V AC 2,000 1,550 Insulation (1.2/50 s) between input and output kV 6 4 EMC specifications Type of test Reference standard Electrostatic discharge contact discharge EN 61000-4-2 n.a. air discharge EN 61000-4-2 8 kV Radio-frequency electromagnetic field (80 1000 MHz) EN 61000-4-3 15 V/m Fast transients (burst) (5-50 ns, 5 kHz) on Supply terminals EN 61000-4-4 4 kV Surges (1.2/50 s) on common mode EN 61000-4-5 4 kV Supply terminals differential mode EN 61000-4-5 2 kV Radio-frequency common mode (0.15 80 MHz) on Supply terminals EN 61000-4-6 10 V Power-frequency (50 Hz) EN 61000-4-8 30 A/m Radiated and conducted emission EN 55022 class B Other data Power lost to the environment without contact current W 1.6 with rated current W 3.7 (85.02) 4.7 (85.03) 3.6 (85.04) Times scales NOTE: time scales and functions must be set before energising the timer. 2