X-On Electronics has gained recognition as a prominent supplier of 87.02.0.240.0000 across the USA, India, Europe, Australia, and various other global locations. 87.02.0.240.0000 are a product manufactured by Finder. We provide cost-effective solutions for 87.02.0.240.0000, ensuring timely deliveries around the world.
We are delighted to provide the 87.02.0.240.0000 from our Finder manufacturer, at competitive rates not only in the United States, Australia, and India, but also across Europe and beyond. A long established and extensive electronic component distribution network has enhanced our global reach and dependability, ensuring cost savings through prompt deliveries worldwide. Client satisfaction is at the heart of our business, where every component counts and every customer matters. Our technical service team is ready to assist you. From product selection to after-sales support, we strive to deliver a seamless and satisfying experience. Are you ready to experience the best in electronic component distribution? Contact X-ON Electronics today and discover why X-On are a preferred choice for the 87.02.0.240.0000 and other electronic components in the Finder manufacturer and beyond.
87 Series - Modular timers 5 - 8 A Features 87.01 87.02 Mono-function and multi-function timer range 22.5 mm wide 87.01 - 1 Pole - Multi-function and multi-voltage 87.02 - 2 Pole - Multi-function and multi-voltage, (timed + instantaneous options) External time setting potentiometer option Wide supply voltage range: (24240)V AC / (2448)V DC Multi-function LED indicator Multi-function Timing can be regulated using ext. Potentiometer Time setting from 0.05 seconds to 60 hours 1 pole 2 timed contacts or 1 timed + 1 instantaneous contact 35 mm rail (EN 50022) mount 35 mm rail (EN 50022) mounting 35 mm rail (EN 50022) mount AI: ON delay AI: ON delay 87.01 / 87.02 BE: Signal OFF delay BE: Signal OFF delay Screw terminal CE: Signal ON and OFF Delay CE: Signal ON and OFF Delay DE: Signal ON pulse DE: Signal ON pulse DI: ON pulse DI: ON pulse 22.5 96 EE a: Signal OFF pulse EE a: Signal OFF pulse GI: Fixed pulse delayed GI: Fixed pulse delayed SW: Symmetrical recycling: ON start SW: Symmetrical recycling: ON start L/+ L/+ L/+ L/+ S S 87.01 (21) (21) 15 A1 A1 B1 15 A1 B1 15 25 A1 B1 15 25 101 22.5 96 A2 Z1 Z2 18 16 28 26 A2 Z1 Z2 18 16 28 26 A2 A2 18 16 18 16 (24 22) (24 22) N/ N/ N/ N/ Wiring diagram Wiring diagram Wiring diagram Wiring diagram 87.02 101 (without signal START) (with signal START) (without signal START) (with signal START) Contact specification Contact configuration 1 CO (SPDT) 2 CO (DPDT) Rated current/Maximum peak current A 8/30 8/30 Rated voltage/Maximum switching voltage V AC 250/400 250/400 Rated load AC1 VA 2,000 2,000 Rated load AC15 (230 V AC) VA 400 400 Single phase motor rating (230 V AC) kW 0.185 0.185 Breaking capacity DC1: 30/110/220 V A 8/0.5/0.2 8/0.5/0.2 Minimum switching load mW (V/mA) 300 (10/5) 300 (10/5) Standard contact material AgCdO AgCdO Supply specification Nominal voltage (U ) V AC (50/60 Hz) 24240 24240 N V DC 24...48 24...48 Rated power AC/DC VA (50 Hz)/W 5/0.5 5/0.5 Operating range AC (0.851.1)U (0.851.1)U N N DC (0.851.2)U (0.851.2)U N N Technical data Specified time range See page 6 See page 6 Repeatability % 2 2 Recovery time ms 50 50 Minimum control impulse ms 50 50 Setting accuracy-full range % 5 5 3 3 Electrical life at rated load in AC1 cycles 10010 10010 Ambient temperature range (Contact current) C 20+70 20+60 / 20+70 (< 5 A) Protection category IP 20 IP 20 Approvals (according to type) 1 78.8 78.8 35 3587 Series - Modular timers 5 - 8 A Features 87.11 87.21 87.31 Mono-function and multi-function timer range 22.5 mm wide 87.11 - ON delay, multi-voltage 87.21 - ON pulse, multi-voltage 87.31 - Symmetrical recycling, multi-voltage 1 Pole output contact Wide supply voltage range: (24240)V AC / (2448)V DC LED indicator Time setting: Mono-function Mono-function Mono-function Types 87.11/21 - 0.05 seconds to 60 hours 35 mm rail (EN 50022) mount 35 mm rail (EN 50022) mount 35 mm rail (EN 50022) mount Type 87.31 - 0.5 seconds to 10 seconds 35 mm rail (EN 50022) mount AI: ON delay DI: ON pulse SW: Symmetrical recycling: ON start 87.11 / 87.21 /87.31 Screw terminal 22.5 96 L/+ L/+ L/+ A1 15 A1 15 A1 15 87.31 101 22.5 96 A2 18 16 A2 18 16 A2 18 16 N/ N/ N/ 87.11 Wiring diagram Wiring diagram Wiring diagram 87.21 (without signal START) (without signal START) (without signal START) 101 Contact specification Contact configuration 1 CO (SPDT) 1 CO (SPDT) 1 CO (SPDT) Rated current/Maximum peak current A 8/30 8/30 8/30 Rated voltage/Maximum switching voltage V AC 250/400 250/400 250/400 Rated load AC1 VA 2,000 2,000 2,000 Rated load AC15 (230 V AC) VA 400 400 400 Single phase motor rating (230 V AC) kW 0.185 0.185 0.185 Breaking capacity DC1: 30/110/220 V A 8/0.5/0.2 8/0.5/0.2 8/0.5/0.2 Minimum switching load mW (V/mA) 300 (10/5) 300 (10/5) 300 (10/5) Standard contact material AgCdO AgCdO AgCdO Supply specification Nominal voltage (U ) V AC (50/60 Hz) 24240 24240 24...240 N V DC 24...48 24...48 24...48 Rated power AC/DC VA (50 Hz)/W 5/0.5 5/0.5 5/0.5 Operating range AC (0.851.1)U (0.851.1)U (0.851.1)U N N N DC (0.851.2)U (0.851.2)U (0.851.2)U N N N Technical data Specified time range See page 6 See page 6 See page 6 Repeatability % 0.2 0.2 0.2 Recovery time ms 50 50 50 Minimum control impulse ms Setting accuracy-full range % 5 5 5 3 3 3 Electrical life at rated load in AC1 cycles 100 10 100 10 100 10 Ambient temperature range C 20+70 20+70 20+70 Protection category IP 20 IP 20 IP 20 Approvals (according to type) 2 78.8 78.8 35 35
Calling all new customers! Register now with Xon Electronics and save 5%, up to 50$, on your first order! Don't miss out – this offer won't last forever!
Discount Code : XONFIRSTUSER