87 Series - Modular timers 5 - 8 A Features 87.01 87.02 Mono-function and multi-function timer range 22.5 mm wide 87.01 - 1 Pole - Multi-function and multi-voltage 87.02 - 2 Pole - Multi-function and multi-voltage, (timed + instantaneous options) External time setting potentiometer option Wide supply voltage range: (24240)V AC / (2448)V DC Multi-function LED indicator Multi-function Timing can be regulated using ext. Potentiometer Time setting from 0.05 seconds to 60 hours 1 pole 2 timed contacts or 1 timed + 1 instantaneous contact 35 mm rail (EN 50022) mount 35 mm rail (EN 50022) mounting 35 mm rail (EN 50022) mount AI: ON delay AI: ON delay 87.01 / 87.02 BE: Signal OFF delay BE: Signal OFF delay Screw terminal CE: Signal ON and OFF Delay CE: Signal ON and OFF Delay DE: Signal ON pulse DE: Signal ON pulse DI: ON pulse DI: ON pulse 22.5 96 EE a: Signal OFF pulse EE a: Signal OFF pulse GI: Fixed pulse delayed GI: Fixed pulse delayed SW: Symmetrical recycling: ON start SW: Symmetrical recycling: ON start L/+ L/+ L/+ L/+ S S 87.01 (21) (21) 15 A1 A1 B1 15 A1 B1 15 25 A1 B1 15 25 101 22.5 96 A2 Z1 Z2 18 16 28 26 A2 Z1 Z2 18 16 28 26 A2 A2 18 16 18 16 (24 22) (24 22) N/ N/ N/ N/ Wiring diagram Wiring diagram Wiring diagram Wiring diagram 87.02 101 (without signal START) (with signal START) (without signal START) (with signal START) Contact specification Contact configuration 1 CO (SPDT) 2 CO (DPDT) Rated current/Maximum peak current A 8/30 8/30 Rated voltage/Maximum switching voltage V AC 250/400 250/400 Rated load AC1 VA 2,000 2,000 Rated load AC15 (230 V AC) VA 400 400 Single phase motor rating (230 V AC) kW 0.185 0.185 Breaking capacity DC1: 30/110/220 V A 8/0.5/0.2 8/0.5/0.2 Minimum switching load mW (V/mA) 300 (10/5) 300 (10/5) Standard contact material AgCdO AgCdO Supply specification Nominal voltage (U ) V AC (50/60 Hz) 24240 24240 N V DC 24...48 24...48 Rated power AC/DC VA (50 Hz)/W 5/0.5 5/0.5 Operating range AC (0.851.1)U (0.851.1)U N N DC (0.851.2)U (0.851.2)U N N Technical data Specified time range See page 6 See page 6 Repeatability % 2 2 Recovery time ms 50 50 Minimum control impulse ms 50 50 Setting accuracy-full range % 5 5 3 3 Electrical life at rated load in AC1 cycles 10010 10010 Ambient temperature range (Contact current) C 20+70 20+60 / 20+70 (< 5 A) Protection category IP 20 IP 20 Approvals (according to type) 1 78.8 78.8 35 3587 Series - Modular timers 5 - 8 A Features 87.11 87.21 87.31 Mono-function and multi-function timer range 22.5 mm wide 87.11 - ON delay, multi-voltage 87.21 - ON pulse, multi-voltage 87.31 - Symmetrical recycling, multi-voltage 1 Pole output contact Wide supply voltage range: (24240)V AC / (2448)V DC LED indicator Time setting: Mono-function Mono-function Mono-function Types 87.11/21 - 0.05 seconds to 60 hours 35 mm rail (EN 50022) mount 35 mm rail (EN 50022) mount 35 mm rail (EN 50022) mount Type 87.31 - 0.5 seconds to 10 seconds 35 mm rail (EN 50022) mount AI: ON delay DI: ON pulse SW: Symmetrical recycling: ON start 87.11 / 87.21 /87.31 Screw terminal 22.5 96 L/+ L/+ L/+ A1 15 A1 15 A1 15 87.31 101 22.5 96 A2 18 16 A2 18 16 A2 18 16 N/ N/ N/ 87.11 Wiring diagram Wiring diagram Wiring diagram 87.21 (without signal START) (without signal START) (without signal START) 101 Contact specification Contact configuration 1 CO (SPDT) 1 CO (SPDT) 1 CO (SPDT) Rated current/Maximum peak current A 8/30 8/30 8/30 Rated voltage/Maximum switching voltage V AC 250/400 250/400 250/400 Rated load AC1 VA 2,000 2,000 2,000 Rated load AC15 (230 V AC) VA 400 400 400 Single phase motor rating (230 V AC) kW 0.185 0.185 0.185 Breaking capacity DC1: 30/110/220 V A 8/0.5/0.2 8/0.5/0.2 8/0.5/0.2 Minimum switching load mW (V/mA) 300 (10/5) 300 (10/5) 300 (10/5) Standard contact material AgCdO AgCdO AgCdO Supply specification Nominal voltage (U ) V AC (50/60 Hz) 24240 24240 24...240 N V DC 24...48 24...48 24...48 Rated power AC/DC VA (50 Hz)/W 5/0.5 5/0.5 5/0.5 Operating range AC (0.851.1)U (0.851.1)U (0.851.1)U N N N DC (0.851.2)U (0.851.2)U (0.851.2)U N N N Technical data Specified time range See page 6 See page 6 See page 6 Repeatability % 0.2 0.2 0.2 Recovery time ms 50 50 50 Minimum control impulse ms Setting accuracy-full range % 5 5 5 3 3 3 Electrical life at rated load in AC1 cycles 100 10 100 10 100 10 Ambient temperature range C 20+70 20+70 20+70 Protection category IP 20 IP 20 IP 20 Approvals (according to type) 2 78.8 78.8 35 35