62 Series - Power relays 16 A Features 62.22 / 62.23 62.22-0300 / 62.23-0300 Printed circuit mount 16 A Power relay 2 & 3 Pole changeover contacts or NO ( 3 mm contact gap) AC coils & DC coils Reinforced insulation between coil and contacts according to EN 60335-1, with 6 mm clearance & 8 mm creepage distance SELV coil-contact separator option Cadmium Free contact material options 2 & 3 pole normally open contact 2 & 3 pole changeover contact ( 3 mm contact gap) PCB mount PCB mount 62.22 62.23 62.2x 62.2x-0300 62.22-0300 62.23-0300 * Distance between contacts 3 mm (EN 60730-1). ** With the AgSnO material the maximum 2 peak current is 120 A - 5 ms (NO contact). 62.22 62.23 62.22 - 0300 62.23 - 0300 FOR UL HORSEPOWER AND PILOT DUTY RATINGS Copper side view Copper side view Copper side view Copper side view SEE General technical information page V Contact specification Contact configuration 2 CO (DPDT) 3 CO (3PDT) 2 NO (DPST-NO), 3 mm* 3 NO (3PST-NO), 3 mm* Rated current/Maximum peak current A 16/30** 16/30** Rated voltage/Maximum switching voltage V AC 250/400 250/400 Rated load AC1 VA 4,000 4,000 Rated load AC15 (230 V AC) VA 750 750 Motor rating (230/400 V AC) kW 0.8/ 0.8/1.5 0.8/ 0.8/1.5 Breaking capacity DC1: 30/110/220 V A 16/0.6/0.4 16/1.1/0.7 Minimum switching load mW (V/mA) 1,000 (10/10) 1,000 (10/10) Standard contact material AgCdO AgCdO Coil specification Nominal voltage (U ) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400 N V DC 6 - 12 - 24 - 48 - 60 - 110 - 125 - 220 Rated power AC/DC VA (50 Hz)/W 2.2/1.3 3/3 Operating range AC (0.81.1)U (0.851.1)U N N DC (0.81.1)U (0.851.1)U N N Holding voltage AC/DC 0.8 U /0.6 U 0.8 U /0.6 U N N N N Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U /0.1 U N N N N Technical data 6 6 6 6 Mechanical life AC/DC cycles 10 10 /30 10 10 10 /30 10 3 3 Electrical life at rated load AC1 cycles 100 10 100 10 Operate/release time ms 10/10 20/4 Insulation between coil and contacts (1.2/50 s) kV 66 Dielectric strength between open contacts V AC 1,500 2,500 Ambient temperature range C 40+70 40+50 Environmental protection RT I RT I Approvals (according to type) 162 Series - Power relays 16 A Features 62.32 / 62.33 62.32-0300 / 62.33-0300 Plug-in mount/Faston 187 16 A Power relay Plug-in (92 series sockets) or Faston 187 (4.8x0.5 mm) with optional mounting adaptors 2 & 3 Pole changeover contacts or NO ( 3 mm contact gap) AC coils & DC coils UL Listing (certain relay/socket combinations) LED, mechanical indicator & test button options 2 & 3 pole normally open contact Reinforced insulation between coil and 2 & 3 pole changeover contact ( 3 mm contact gap) contacts according to EN 60335-1, with Plug-in / Faston 187 Plug-in / Faston 187 6 mm clearance & 8 mm creepage distance SELV coil-contact separator option Cadmium Free contact material options Sockets and accessories 62.32 62.33 62.3x 62.3x-0300 62.32-0300 62.33-0300 * Distance between contacts 3 mm (EN 60730-1). ** With the AgSnO material the maximum 2 peak current is 120 A - 5 ms (NO contact). FOR UL HORSEPOWER AND PILOT DUTY RATINGS 62.32 62.33 62.32-0300 62.33-0300 SEE General technical information page V Contact specification Contact configuration 2 CO (DPDT) 3 CO (3PDT) 2 NO (DPST-NO), 3 mm* 3 NO (3PST-NO), 3 mm* Rated current/Maximum peak current A 16/30** 16/30** Rated voltage/Maximum switching voltage V AC 250/400 250/400 Rated load AC1 VA 4,000 4,000 Rated load AC15 (230 V AC) VA 750 750 Motor rating (230/400 V AC) kW 0.8/ 0.8/1.5 0.8/ 0.8/1.5 Breaking capacity DC1: 30/110/220 V A 16/0.6/0.4 16/1.1/0.7 Minimum switching load mW (V/mA) 1,000 (10/10) 1,000 (10/10) Standard contact material AgCdO AgCdO Coil specification Nominal voltage (U ) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400 N V DC 6 - 12 - 24 - 48 - 60 - 110 - 125 - 220 Rated power AC/DC VA (50 Hz)/W 2.2/1.3 3/3 Operating range AC (0.81.1)U (0.851.1)U N N DC (0.81.1)U (0.851.1)U N N Holding voltage AC/DC 0.8 U /0.6 U 0.8 U /0.6 U N N N N Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U /0.1 U N N N N Technical data 6 6 6 6 Mechanical life AC/DC cycles 10 10 /30 10 10 10 /30 10 3 3 Electrical life at rated load AC1 cycles 100 10 100 10 Operate/release time ms 10/10 20/4 Insulation between coil and contacts (1.2/50 s) kV 66 Dielectric strength between open contacts V AC 1,500 2,500 Ambient temperature range C 40+70 40+50 Environmental protection RT I RT I Approvals (according to type) 2