86 Series - Timer modules Features 86.00 86.30 Timer modules for use in conjunction with relay & socket. 86.00 - Multi-function & multi-voltage timer module 86.30 - Bi-function & multi-voltage timer module Timer module for 90, 92 series sockets for type 86.00 and 90, 92, 94, 95, 97 series sockets for type 86.30 Time scale: from 0.05s to 100h Time scale: from 0.05s to 100h Wide supply voltage range: Bi-function Multi-function 12...240 V AC/DC (86.00) Plug-in for use with 90.02, 90.03, 92.03, Plug-in for use with 90.02, 90.03 and 92.03 12...24 V AC/DC or 230...240 V AC (86.30) 94.02, 94.03, 94.04, 95.03, 95.05, 95.55, sockets LED indicator 97.01, 97.02, 97.51 and 97.52 sockets 38 AI: ON delay AI: ON delay DI: ON pulse DI: ON pulse 86.00 SW: Symmetrical recycling: ON start BE: Signal OFF delay CE: Signal ON & OFF delay DE: Signal ON pulse EE: Signal OFF pulse FE: Signal ON delay + OFF pulse 10,5 6,3 Relay + socket Relay + socket Relay + socket A2 A1 B1 A2 A1 B1 A2 A1 15.5 11.3 86.30 S U U U N/ L/+ N/ L/+ N/ L/+ Wiring diagram Wiring diagram Wiring diagram 10.5 without signal START with signal START 14.1 Contact specification Contact configuration Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC Rated load AC1 VA See 60 and 62 series relays See 40, 44, 46, 55, 60 and 62 series relays Rated load AC15 (230 V AC) VA Note: Do not use with relays Single phase motor rating (230 V AC) kW 62.3x.x012.x300 and 62.3x.x012.x600 Breaking capacity DC1: 30/110/220 V A Minimum switching load mW (V/mA) Standard contact material Supply specification Nominal voltage (U ) V AC (50/60 Hz) 12240 1224 230...240 N 12240 1224 V DC 1.2 0.15 Rated power AC/DC W 10.2265 9.633.6 184...265 Operating range V AC (50/60 Hz) DC 10.2265 9.633.6 Technical data Specified time range (0.05...1)s, (0.510)s, (5100)s, (0.510)min, (5100)min, (0.510)h, (5100)h 1 1 Repeatability % 50 50 Recovery time ms 50 Minimun control impulse ms 5 5 Setting accuracy full range % Electrical life at rated load in AC1 cycles See 60 and 62 series relays See 40, 44, 46, 55, 60 and 62 series relays Ambient temperature range C 20+50 20+50 Protection category IP 20 IP 20 Approvals (according to type) 1 54 31 1.6 4.986 Series - Timer modules Ordering information Example: 86 series multi-function timer module, (12...240)V AC/DC supply voltage. 86..0 0 0.24 0. 0 0 0 0 Series Supply voltage 024 = (12...24)V AC/DC (86.30 only) Type 240 = (12...240)V AC/DC (86.00 only) 0 = Multi-function (AI, DI, SW, BE, CE, DE, EE, FE) 240 = (230...240)V AC (86.30 only) 3 = Bi-function (AI, DI) Supply version No. of poles 0 = AC (50/60 Hz)/DC See 40, 44, 46, 55, 60 and 62 series relays 8 = AC (50/60 Hz) Poles for chosen relay/socket combination - according to chart below Number of poles Relay type Socket type Timer module Combinations 1 40.31 95.03 86.30 1 40.61 95.05 86.30 1 46.61 97.01/97.51 86.30 2 40.52/44.52/44.62 95.05/95.55 86.30 2 46.52 97.02/97.52 86.30 2 55.32 94.02 86.30 2 60.12 90.02 86.00/86.30 2 62.32 92.03 86.00/86.30 3 55.33 94.03 86.30 3 60.13 90.03 86.00/86.30 3 62.33 92.03 86.00/86.30 4 55.34 94.04 86.30 Technical data EMC specifications Type of test Reference standard 86.00 86.30 Electrostatic discharge contact discharge EN 61000-4-2 4 kV n.a. air discharge EN 61000-4-2 8 kV 8 kV Radio-frequency electromagnetic field (80 1000 MHz) EN 61000-4-3 10 V/m 10 V/m Fast transients (burst) (5-50 ns, 5 kHz) on Supply terminals EN 61000-4-4 4 kV 4 kV Surges (1.2/50 s) on Supply terminals common mode EN 61000-4-5 4 kV 4 kV differential mode EN 61000-4-5 4 kV 2 kV Radio-frequency common mode (0.15 80 MHz) EN 61000-4-6 10 V 10 V on Supply terminals Radiated and conducted emission EN 55022 classe B classe B Other data 86.00 86.30 Current absorption on signal control (B1) mA 1 Power lost to the environment without contact current W 0.1 (12 V) - 1 (230 V) 0.2 with rated current See 60 and 62 series relays See 40, 44, 46, 55, 60 , 62 series relays Time scales 12 3 1 2 3 12 3 1 2 3 12 3 1 2 3 12 3 (0.05...1)s (0.5...10)s (5...100)s (0.5...10)min (5...100)min (0.5...10)h (5...100)h NOTE: time scales and functions must be set before energising the timer. 2