40 Series - Miniature PCB/Plug-in relays 8 - 10 - 16 A Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31 - 1 Pole 10 A (3.5 mm pin pitch) 40.51 - 1 Pole 10 A (5 mm pin pitch) 40.52 - 2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail mount - via screw and screwless sockets DC coils (standard or sensitive) & AC coils Cadmium Free contact material 3.5 mm contact pin pitch 5 mm contact pin pitch 5 mm contact pin pitch 8 mm, 6 kV (1.2/50 s) isolation, coil-contacts 1 Pole 10 A 1 Pole 10 A 2 Pole 8 A UL Listing (certain relay/socket combinations) PCB or 95 series sockets PCB or 95 series sockets PCB or 95 series sockets Flux proof: RT II standard, (RT III option) 95 series sockets Coil EMC suppression Timer accessories 86 series FOR UL RATINGS SEE: Copper side view Copper side view Copper side view General technical information page V Contact specification Contact configuration 1 CO (SPDT) 1 CO (SPDT) 2 CO (DPDT) Rated current/Maximum peak current A 10/20 10/20 8/15 Rated voltage/Maximum switching voltage V AC 250/400 250/400 250/400 Rated load AC1 VA 2,500 2,500 2,000 Rated load AC15 (230 V AC) VA 500 500 400 Single phase motor rating (230 V AC) kW 0.37 0.37 0.3 Breaking capacity DC1: 30/110/220 V A 10/0.3/0.12 10/0.3/0.12 8/0.3/0.12 Minimum switching load mW (V/mA) 300 (5/5) 300 (5/5) 300 (5/5) Standard contact material AgNi AgNi AgNi Coil specification Nominal voltage (U ) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 N V DC 5 - 6 - 7 - 9 - 12 - 14 - 18 - 21 - 24 - 28 - 36 - 48 - 60 - 90 - 110 - 125 Rated power AC/DC/sens. DC VA (50 Hz)/W/W 1.2/0.65/0.5 1.2/0.65/0.5 1.2/0.65/0.5 Operating range AC (0.81.1)U (0.81.1)U (0.81.1)U N N N DC/sens. DC (0.731.5)U /(0.731.75)U (0.731.5)U /(0.731.75)U (0.731.5)U /(0.731.75)U N N N N N N Holding voltage AC/DC 0.8 U /0.4 U 0.8 U /0.4 U 0.8 U /0.4 U N N N N N N Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U /0.1 U 0.2 U /0.1 U N N N N N N Technical data 6 6 6 6 6 6 Mechanical life AC/DC cycles 10 10 /20 10 10 10 /20 10 10 10 /20 10 3 3 3 Electrical life at rated load AC1 cycles 200 10 200 10 100 10 Operate/release time ms 7/3 - (12/4 sensitive) 7/3 - (12/4 sensitive) 7/3 - (12/4 sensitive) Insulation between coil and contacts (1.2/50 s) kV 6 (8 mm) 6 (8 mm) 6 (8 mm) Dielectric strength between open contacts V AC 1,000 1,000 1,000 Ambient temperature range C 40+85 40+85 40+85 Environmental protection RT II** RT II** RT II** Approvals (according to type) 1 ** See general technical information Guidelines for automatic flow solder processes page II . XII-2012, www.findernet.com40 Series - Miniature PCB/Plug-in relays 8 - 10 - 16 A Features 40.61 40.xx.6 40.61 - 1 Pole 16 A (5 mm pin pitch) 40.xx.6 - Bistable versions of the 40.31, 40.51, 40.52 & 40.61 relays PCB mount - direct or via PCB socket 35 mm rail mount - via screw and screwless sockets DC coils & AC coils Cadmium Free option available 8 mm, 6 kV (1.2/50 s) isolation, coil-contacts 5 mm contact pin pitch Bistable (single coil) versions UL Listing (certain 40.61 relay/socket combinations) 1 Pole 16 A of 40.31/51/52/61 PCB or 95 series sockets PCB or 95 series sockets Flux proof: RT II standard, (RT III option) 95 series sockets Coil EMC suppression Timer accessories 86 series Bistable version (1 coil) types: 40.31.6... 40.51.6... 40.52.6... 40.61.6... For wiring diagrams see page 8 FOR UL RATINGS SEE: Copper side view General technical information page V Contact specification Contact configuration 1 CO (SPDT) Rated current/Maximum peak current A 16/30* * With the AgSnO material 2 the maximum peak current is Rated voltage/Maximum switching voltage V AC 250/400 See relays 120 A - 5 ms on normally Rated load AC1 VA 4,000 40.31 open contact. Rated load AC15 (230 V AC) VA 750 40.51 Single phase motor rating (230 V AC) kW 0.55 40.52 Breaking capacity DC1: 30/110/220 V A 16/0.3/0.12 40.61 Minimum switching load mW (V/mA) 500 (10/5) Standard contact material AgCdO Coil specification Nominal voltage (U ) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 5 - 6 - 12 - 24 - 48 - 110 N V DC ***See table 5 - 6 - 12 - 24 - 48 - 110 *** Nominal voltage (U ): N 5 - 6 - 7 - 9 - 12 - 14 - 18 - 21 - Rated power AC/DC/sens. DC VA (50 Hz)/W/W 1.2/0.65/0.5 1.0/1.0/ 24 - 28 - 36 - 48 - 60 - 90 - Operating range AC (0.81.1)U (0.81.1)U N N 110 - 125 V DC DC/sens. DC (0.731.5)U /(0.81.5)U (0.81.1)U / N N N Holding voltage AC/DC 0.8 U /0.4 U N N Must drop-out voltage AC/DC 0.2 U /0.1 U N N Technical data 6 6 Mechanical life AC/DC cycles 10 10 /20 10 See relays 3 Electrical life at rated load AC1 cycles 100 10 40.31 Operate/release time ms 7/3 - (12/4 sensitive) 40.51 Insulation between coil and contacts (1.2/50 s) kV 6 (8 mm) 40.52 Dielectric strength between open contacts V AC 1,000 40.61 Ambient temperature range C 40+85 Min. impulse duration Environmental protection RT II** 20 ms Approvals (according to type) 2 ** See general technical information Guidelines for automatic flow solder processes page II. XII-2012, www.findernet.com