56 Series - Miniature power relays 12 A Features 56.32/56.34 56.32-0300/56.34-0300 Plug-in - 12 A Power relay, 2 & 4 pole Flange mount option - (Faston 187, 4.8x0.5 mm termination) AC coils & DC coils Lockable test button and mechanical flag indicator Cadmium Free contacts (standard version) Contact material options 96 series sockets Coil EMC suppression Accessories European Patent 2 or 4 pole normally open contact 2 or 4 pole changeover contact (1.5 mm gap) Plug-in/Faston 187 Plug-in/Faston 187 56.32 56.32-0300 56.34 56.34-0300 * For 4 CO (4PDT) or 4 NO only. FOR UL RATINGS SEE: 56.32 56.34 56.32-0300 56.34-0300 General technical information page V Contact specification Contact configuration 2 CO (DPDT) 4 CO (4PDT) 2NO (DPST-NO) - 1.5mm gap 4NO (4PST-NO) - 1.5mm gap Rated current/Maximum peak current A 12/20 12/20 Rated voltage/Maximum switching voltage V AC 250/400 250/400 Rated load AC1 VA 3,000 3,000 Rated load AC15 (230 V AC) VA 700 700 Single phase motor rating (230 V AC) kW 0.55 0.55 Breaking capacity DC1: 30/110/220 V A 12/0.5/0.25 12/1/0.5 Minimum switching load mW (V/mA) 500 (10/5) 500 (10/5) Standard contact material AgNi AgNi Coil specification Nominal voltage (U ) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400* N V DC 6 - 12 - 24 - 48 - 60 - 110 - 125 - 220 Rated power AC/DC VA (50 Hz)/W 1.5/1 2/1.3 1.5/ 2/ Operating range AC (0.81.1)U (0.851.1)U N N DC (0.81.1)U (0.851.1)U N N Holding voltage AC/DC 0.8 U /0.6 U 0.85 U / N N N Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U / N N N Technical data 6 6 6 Mechanical life AC/DC cycles 20 10 /50 10 20 10 / 3 3 Electrical life at rated load AC1 cycles 100 10 100 10 Operate/release time ms 8/3 10/4 8/4 Insulation between coil and contacts (1.2/50 s) kV45 4 5 Dielectric strength between open contacts V AC 1,000 2,000 Ambient temperature range C 40+70 40+70 Environmental protection RT I RT I Approvals (according to type) 156 Series - Miniature power relays 12 A Features 56.42/56.44 56.42-0300/56.44-0300 Printed circuit mount 12 A Power relay 2 & 4 pole AC coils & DC coils Cadmium Free contacts (standard version) Contact material option RT III (wash tight) option available 2 or 4 pole normally open contact 2 or 4 pole changeover contact ( 1.5 mm gap) PCB mount PCB mount 56.42 56.42-0300 56.44 56.44-0300 * For 4 CO (4PDT) or 4 NO only. 56.42 56.44 56.42-0300 56.44-0300 Copper side view Copper side view Copper side view Copper side view FOR UL RATINGS SEE: General technical information page V Contact specification Contact configuration 2 CO (DPDT) 4 CO (4PDT) 2NO (DPST-NO) - 1.5mm gap 4NO (4PST-NO) - 1.5mm gap Rated current/Maximum peak current A 12/20 12/20 Rated voltage/Maximum switching voltage V AC 250/400 250/400 Rated load AC1 VA 3,000 3,000 Rated load AC15 (230 V AC) VA 700 700 Single phase motor rating (230 V AC) kW 0.55 0.55 Breaking capacity DC1: 30/110/220 V A 12/0.5/0.25 12/1/0.5 Minimum switching load mW (V/mA) 500 (10/5) 500 (10/5) Standard contact material AgNi AgNi Coil specification Nominal voltage (U ) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400* N V DC 6 - 12 - 24 - 48 - 60 - 110 - 125 - 220 Rated power AC/DC VA (50 Hz)/W 1.5/1 2/1.3 1.5/ 2/ Operating range AC (0.81.1)U (0.851.1)U N N DC (0.81.1)U (0.851.1)U N N Holding voltage AC/DC 0.8 U /0.6 U 0.85 U / N N N Must drop-out voltage AC/DC 0.2 U /0.1 U 0.2 U / N N N Technical data 6 6 6 Mechanical life AC/DC cycles 20 10 /50 10 20 10 / 3 3 Electrical life at rated load AC1 cycles 100 10 100 10 Operate/release time ms 8/3 10/4 8/4 Insulation between coil and contacts (1.2/50 s) kV 45 4 5 Dielectric strength between open contacts V AC 1,000 2,000 Ambient temperature range C 40+70 40+70 Environmental protection RT I RT I Approvals (according to type) 2