46 SERIES 46 Series - Miniature industrial relays 8 - 16 A Features 46.52 46.61 1 & 2 Pole relay range 46.52 - 2 Pole 8 A A 46.61 - 1 Pole 16 A Socket mount or direct connection via Faston connectors AC coils & DC coils Available with: lockable test button, mechanical indicator & LED indicator 8 mm, 6 kV (1.2/50 s) isolation, coil-contacts Cadmium Free contacts 2 Pole CO, 8 A 1 Pole CO, 16 A European Patent Plug-in/Solder terminals Plug-in/Faston 187 46.52 29 12.4 46.61 4.75 0.5 4.75 FOR UL RATINGS SEE: General technical information page V Contact specification Contact configuration 2 CO (DPDT) 1 CO (SPDT) Rated current/Maximum peak current A 8/15 16/25 * * With the AgSnO material 2 the maximum peak current is Rated voltage/Maximum switching voltage V AC 250/440 250/440 80 A - 5 ms on normally Rated load AC1 VA 2,000 4,000 open contact. Rated load AC15 (230 V AC) VA 350 750 Single phase motor rating (230 V AC) kW 0.37 0.55 Breaking capacity DC1: 30/110/220 V A 6/0.5/0.15 12/0.5/0.15 300 (5/5) 300 (5/5) Minimum switching load mW (V/mA) Standard contact material AgNi AgNi Coil specification Nominal voltage (U ) V AC (50/60 Hz) 12 - 24 - 48 - 110 - 120 - 230 - 240 N V DC 12 - 24 - 48 - 110 - 125 Rated power VA/W 1.2/0.5 1.2/0.5 Operating range AC (0.8...1.1)U (0.8...1.1)U N N (0.73...1.1)U (0.73...1.1)U DC N N Holding voltage AC/DC 0.8U /0.4U 0.8U /0.4U N N N N Must drop-out voltage AC/DC 0.2U /0.1U 0.2U /0.1U N N N N Technical data 6 6 Mechanical life AC/DC cycles 10 10 10 10 3 3 Electrical life at rated load AC1 cycles 100 10 100 10 Operate/release time ms 10/3 15/5 Insulation between coil and contacts (1.2/50 s)kV 6 (8 mm) 6 (8 mm) Dielectric strength between open contacts V AC 1,000 1,000 Ambient temperature range C 40 ... +70 40 ... +70 Environmental protection RT II RT II Approvals (according to type) 1 I-2014, www.findernet.com 20 6.5 32.8E P O R U E N A 46 SERIE S 46 Series - Miniature industrial relays 8 - 16 A Ordering information Example: 46 series Miniature industrial relay, 1 CO (SPDT), 24 V DC coil, lockable test button and mechanical indicator. AB C D A 46..6 1 9.02 4. 0 0 4 0 Series A: Contact material D: Special versions 0 = AgNi 0 = Standard Type 4 = AgSnO (46.61 only) 2 5 = Spade/blade solder terminal C: Options 5 = AgNi + Au (2.5x0.5)mm 2 =Mechanical indicator 6 = Spade/blade terminal 4 =Lockable test button + B: Contact circuit Faston 187 (4.8x0.5)mm mechanical indicator 0 = CO (nPDT) 54 =Lockable test button + LED (AC) + No. of poles mechanical indicator 1 = 1 pole, 16 A 74 =Lockable test button + double LED 2 = 2 poles, 8 A (DC non-polarized) + mechanical indicator Coil version 9 = DC 8 = AC (50/60 Hz) Coil voltage See coil specifications Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold. Type Coil version A B C D 46.52 AC - DC 0 - 5 0 2 - 40 AC 0 - 5 0 54 / DC 0 - 5 0 74 / 46.61 AC - DC 0 - 4 - 5 0 2 - 40 AC 0 - 4 - 5 0 54 / DC 0 - 4 - 5 0 74 / Special versions for Rail Applications on request Descriptions: Options C: Option 54 C: Option 74 LED (AC) LED (DC, non-polarized) 2 Lockable test button and mechanical flag indicator (0040, 0054, 0074) The dual-purpose Finder test button can be used in two ways: 3 1 Case 1) The plastic pip (located directly below the test button) remains intact. In this case, when the test button is pushed, the contacts operate. When the test button is released the contacts return to their former state. Case 2) The plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to the above function), when the test button is pushed and rotated, the contacts are latched in the operating state, and remain so until the test button is rotated back to its former position. In both cases ensure that the test button actuation is swift and decisive. 2 E P P A TENT O R U E I-2014, www.findernet.com N A