I/O Modules AC/DC Input Modules FEATURES TUV Rheinland Transient Protection: Meets the requirements of IEEE 472, Surge Withstanding Capability Test* Non-Polarized Types Provide Inputs For AC or DC UL Recognized, CSA Certified, CE Mark, TV (see Engineering Information) Optical Isolation OpenLine and G5 Modules have Built- in Status LED 70L-IDC 70G-IDC 70-IDC 70M-IDC DIMENSIONS For complete dimensional drawings, see pages H-4 or H-5. CIRCUITRY OpenLine Standard, Mini, G5 I/O MODULE Rx TYPICAL WIRING FOR MODULE 0 PIN 1 VAC 6 Vcc A 2 +/- INPUT 1 1 DEVICE FILTER 7 CH. A STATUS OPTICAL HYSTERESIS ISOLATION 5 GND +/- 2 2 +VCC INPUT 3 VOLTAGE HYST. CIRC. +/- INPUT 3 B 3 DEVICE FILTER 8 CH. B STATUS CURRENT OPTICAL DC HYSTERESIS REGULATING OUTPUT ISOLATION * SUPPLY +/- 4 4 4 GROUND 5 BASE 9 TERMINAL MODULE ID OR 0 BLOCK RACK MODULE Status LED in G5 and OpenLine modules only. * Separate supplies may also be used. SPECIFICATIONS: By Package Style Package Style Std (70-) Mini (70M-) G5 (70G-) OL (70L-) Specifications Units Output Current Range mA 1-50 1-50 1-50 1-50 Min. Output Breakdown Voltage Vdc 50 50 50 50 1 Isolation Voltage Vrms 4000 4000 4000 2500 2 Vibration MIL-STD-202 MIL-STD-202 MIL-STD-202 IEC68-2-6 3 Mechanical Shock MIL-STD-202 MIL-STD-202 MIL-STD-202 IEC68-2-27 Storage Temp. Range C -40 to 125 -40 to 125 -40 to 125 -40 to 100 Operating Temp. Range C -40 to 100 -40 to 100 -40 to 100 -40 to 85 Warranty Lifetime Lifetime Lifetime Lifetime 1 Field to logic and channel-to-channel if Grayhill racks are used. 2 2 MIL-STD-202, Method 204, 20 Gs, 10-2000 Hz or IEC68-2-6, 0.15 mm/sec , 10-150 Hz. 3 MIL-STD-202, Method 213, Condition F, 1500 Gs or IEC68-2-27, 11 mS, 15 gs. H-17 Grayhill, Inc. 561 Hillgrove Avenue LaGrange, Illinois 60525-5997 USA Phone: 708-354-1040 Fax: 708-354-2820 I/O Modules AC/DC Input Modules SPECIFICATIONS: By Part Number Standard and Miniature Modules Type/Function Grayhill Part Number Miniature, Non-Polarized 70M-IDC5G 70M-IDC5NP Standard, Non-Polarized 70-IDC5G 70-IDC-5NP 70-IDC15NP 70-IDC24NP Specifications Units Maximum Input Voltage Vac/Vdc 60 32 28 32 1 Input Voltage Range Vac/Vdc 35-60 15-32/10-32 15-32/10-32 15-32/10-32 Input Current Max. Input Voltage mA 6 25 25 25 Maximum Turn-on Time mSec 10 5 5 5 Maximum Turn-off Time mSec 10 5 5 5 Nominal Input Resistance (Rx) 10K 1.8K 1.8K 1.8K Maximum Pick Up Voltage (Output Low) Vac/Vdc 35 15/10 15/10 15/10 Minimum Drop Out Voltage (Output High) Vac/Vdc 9 3 3 3 Nominal Logic Voltage (Vcc) Vdc 5 5 15 24 Logic Voltage Range Vdc 3-6 3-6 8-18 15-30 Max. Logic Supply Current Nominal Vcc mA 10 10 10 10 G5 Modules Type/Function Grayhill Part Number G5, Non-Polarized, Status LED 70G-IDC5G 70G-IDC5NP 70G-IDC15NP 70G-IDC24NP Specifications Units Maximum Input Voltage Vac/Vdc 60 32 28 32 1 Input Voltage Range Vac/Vdc 35-60 15-32/10-32 15-32/10-32 15-32/10-32 Input Current Max. Input Voltage mA 6 25 25 25 Maximum Turn-on Time mSec 10 5 5 5 Maximum Turn-off Time mSec 10 5 5 5 Nominal Input Resistance (Rx) 10K 1.8K 1.8K 1.8K Maximum Pick Up Voltage (Output Low) Vac/Vdc 35 15/10 15/10 15/10 Minimum Drop Out Voltage (Output High) Vac/Vdc 9 3 3 3 Nominal Logic Voltage (Vcc) Vdc 5 5 15 24 Logic Voltage Range: Std & Mini Vdc 4.5-6 4.5-6 10-18 17-30 Max. Logic Supply Current Nominal Vcc mA 10 10 10 10 OpenLine Modules Available from your local Grayhill Distributors Type/Function Grayhill Part Number For prices and discounts, contact a local Sales Office, an authorized local Distributor, or Grayhill. Dual, Non-Polarized, Status LED 70L-IDCG 70L-IDCNP Specifications Units Maximum Input Voltage Vac/Vdc 60 32 1 Input Voltage Range Vac/Vdc 35-60 15-32/10-32 Input Current Max. Input Voltage mA 6 25 Maximum Turn-on Time mSec 10 5 Maximum Turn-off Time mSec 10 5 Nominal Input Resistance (Rx) 10.6K 1.9K Maximum Pick Up Voltage (Output Low) Vac/Vdc 35 15/10 Minimum Drop Out Voltage (Output High) Vac/Vdc 9 3 Nominal Logic Voltage (Vcc) Vdc 5 5 Logic Voltage Range Vdc 4.5-28 4.5-28 Max. Logic Supply Current Nominal Vcc mA 6/CH 6/CH Module ID Resistance to Logic Ground 00 1 For input voltages in the range of 90 to 140 Vdc, use AC input modules 70-IAC5, 70M-IAC5, 70G- IAC5 or 70L-IAC. For input voltages in the range of 180 to 280 Vdc, use AC input modules 70-IAC5A, 70M-IAC5A, 70G-IAC5A or 70L-IACA. H-18 Grayhill, Inc. 561 Hillgrove Avenue LaGrange, Illinois 60525-5997 USA Phone: 708-354-1040 Fax: 708-354-2820