I/O Modules AC Output Modules FEATURES Transient Protection: Meets the requirements of IEEE 472, Surge Withstanding Capability Test SPST, Normally Open Zero Crossing Turn-On UL, CSA, CE, TV Certified Optical Isolation OpenLine and G5 Modules Provide Replaceable 5x20 mm Glass Fuses Built-in Status LED Lifetime Warranty 70L-OAC 70G-OAC 70-OAC 70M-OAC 4 Maximum Current Versus DIMENSIONS STANDARD, G5 PACKAGES Ambient Temperature For complete dimensional drawings, see pages MINIATURE PACKAGE 3 The chart indicates continuous current to limit L-4 or L-5. the junction temperatures to 100C. Information OPENLINE PACKAGE/CH is based on steady state heat transfer in a 2 2 FUSES cubic foot sealed enclosure. G5 Fuses are 5 Amp Littelfuse part number 1 217005 or equivalent. OpenLine fuses are 3.15 Amp Littelfuse part number 2173.15. -40 -20 0 20 40 60 80 100 AMBIENT TEMPERATURE (C) Figure 1 CIRCUITRY Standard, Mini, G5 OpenLine TYPICAL WIRING FOR MODULE 0 1 I/O MODULE LOAD PIN GND VAC 5 SNUBBER CHANNEL A Vcc 6 11 LOAD 2 LOAD A OPTICAL SNUBBER ISOLATION TRIGGER 22 CH. A CONTROL 7 CIRCUIT 33 B OPTICAL SNUBBER ISOLATION Rx CH. B CONTROL LOAD 3 44 + CHANNEL B DC CONTROL 2.15K 4 TERMINAL MODULE ID RACK BLOCK OR MODULE BASE Fuse and status LED in G5 and OpenLine modules only. SPECIFICATIONS: By Package Style Package Style Std (70-) Mini (70M-) G5 (70G-) OL (70L-) Specifications Units 1 Load Current Range A rms 0.03 to 3.5 0.03 to 3.0 0.03 to 3.5 0.03 to 2.0/CH 2 Maximum 1 Cycle Surge A rms 80 80 80 30 3 Maximum Turn-On-Time (60 Hz) mSec 8.33 8.33 8.33 8.33 Maximum Turn-Off Time (60 Hz) mSec 8.33 8.33 8.33 8.33 7 Static dv/dt V/sec 3000 3000 3000 3000 Typ. Power Dissipation W/A 1.0 1.0 1.0 1.0 4 Isolation Voltage V rms 4000 4000 4000 2500 5 Vibration MIL-STD-202 MIL-STD-202 MIL-STD-202 IEC68-2-6 6 Mechanical Shock MIL-STD-202 MIL-STD-202 MIL-STD-202 IEC68-2-27 Storage Temp. Range C -40 to 125 -40 to 125 -40 to 125 -40 to 100 Operating Temp. Range C -40 to 100 -40 to 100 -40 to 100 -40 to 85 Warranty Lifetime Lifetime Lifetime Lifetime 1 See Figure 1 for derating. 2 Maximum 10 cycle surge is 50% of 1 cycle surge. Application of maximum surge may not be repeated until module temperature has returned to its steady state value. 3 Except 70-OAC5A5 which is 200 Sec and 70-OAC5A-11, 70M-OAC5A-11, and 70G-OAC5A-11 which are 100 Sec. 4 Field to logic and channel-to-channel if Grayhill racks are used. 5 2 MIL-STD-202, Method 204, 20 , 10-2000 Hz or IEC68-2-6, 0.15 mm/sec , 10-150 Hz. 6 MIL-STD-202, Method 213, Condition F, 1500G or IEC68-2-27, 11 mS, 15g. 7 Except part numbers with -L suffix which have a dv/dt rating of 200 V/Sec. I/O 6 Grayhill, Inc. 561 Hillgrove Avenue LaGrange, Illinois 60525-5997 USA Phone: 708-354-1040 Fax: 708-354-2820 www.grayhill.com LOAD CURRENT (AMPS)I/O Modules 76276 1&7. 5 SPECIFICATIONS: By Part Number Standard and Miniature Modules Type/Function Grayhill Part Number Miniature, Normally Open, Random Turn-on 70M-OAC5A-11 Miniature, Normally Open, Zero Voltage Turn-on (ZVT) 70M-OAC5 70M-OAC5A 70M-OAC15 70M-OAC24 70M-OAC24A Miniature, Normally Open, ZVT, Inductive Load 70M-OAC5-L 70M-OAC5A-L Standard, Normally Closed, Random Turn-on 70-OAC5A5 Standard, Normally Open, Random Turn-on 70-OAC5A-11 70-OAC24A-11 Standard, Normally Open, ZVT 70-OAC5 70-OAC5A 70-OAC15 70-OAC15A 70-OAC24 70-OAC24A Standard, Normally Open, ZVT, Inductive Load 70-OAC5-L 70-OAC5A-L Specifications Units Nominal Line Voltage Vac 120 240 120 240 120 240 Load Voltage Range Vac 24-140 24-280 24-140 24-280 24-140 24-280 Minimum Peak Blocking Voltage Volts 400 600 400 600 400 600 Maximum Off-state Leakage 60Hz mA, rms 2 4 2 4 2 4 Nominal Logic Voltage (Vcc) Vdc 5 5 15 15 24 24 Logic Voltage Range Vdc 2.5-10 2.5-10 10-18 10-18 15-30 15-30 Max. Logic Supply Current Nominal Vcc mA 16 16 9 9 9 9 Nominal Input Resistance (Rx) W 240 240 1800 1800 2700 2700 Minimum Drop Out Voltage Vdc 1 1 1 1 1 1 Maximum Reverse Logic Voltage Vdc -5 -5 -5 -5 -5 -5 G5 Modules Type/Function Grayhill Part Number 70G-OAC5 70G-OAC5A 70G-OAC15 70G-OAC24 70G-OAC24A G5 Fusible, Normally Open, ZVT 70G-OAC5-L 70G-OAC5A-L 70G-OAC15-L 70G-OAC15A-L G5 Fusible, Normally Open, ZVT, Inductive Load Specifications Units Nominal Line Voltage Vac 120 240 120 240 120 240 Load Voltage Range Vac 24-140 24-280 24-140 24-280 24-140 24-280 Minimum Peak Blocking Voltage Volts 400 600 400 600 400 600 Maximum Off-state Leakage 60Hz mA, rms 2 4 2 4 2 4 Nominal Logic Voltage (Vcc) Vdc 5 5 15 15 24 24 Logic Voltage Range Vdc 4-6 4-6 8-20 8-20 18-32 18-32 Max. Logic Supply Current Nominal Vcc mA 20 20 12 12 8 8 Nominal Input Resistance (Rx) W 100 100 1000 1000 2700 2700 Minimum Drop Out Voltage Vdc 1 1 1 1 1 1 Maximum Reverse Logic Voltage Vdc -5 -5 -5 -5 -5 -5 OpenLine Modules Available from your local Grayhill Distributor. For Type/Function Grayhill Part Number prices and discounts, contact a local Sales Ofce, Dual, Fusible, Normally Open, ZVT 70L-OAC 70L-OACA an authorized local Distributor or Grayhill. Dual, Fusible, Normally Open, ZVT, Inductive Load 70L-OAC-L 70L-OACA-L Specifications Units Nominal Line Voltage Vac 120 240 Load Voltage Range Vac 24-140 24-280 Minimum Peak Blocking Voltage Volts 600 600 Maximum Off-State Leakage 60 Hz mA, rms 2 4 Nominal Logic Voltage Vdc 5 5 Logic Voltage Range Vdc 4.5-28 4.5-28 Max. Logic Supply Current Nominal Vcc mA 7/CH 7/CH Module ID Resistance to Logic Ground W 2.15K 2.15K Minimum Drop Out Voltage Vdc 1 1 I/O 4 *+..X 0%T IJE +..)418 8 07 4 0) X ..+01+5 JNI FIgIMMK *10 U KNLgGIHgENHN :U KNLgGIHgFLFN 999T) 4 *+..T%1/ 7