I/O Modules Dry Contact and Mechanical Relay Output Modules FEATURES TUV Rheinland SPST, Normally Open UL Recognized, CSA Certified (see Engineering Information) 1500 Vac Optical Isolation G5 Modules Provide Replaceable 5 x 20 mm Glass Fuse Built-in Status LED Lifetime Warranty Switch AC or DC with the Same Module No Off-State Leakage Current 70G-ODC/OAC 70-ODC/OAC 70M-ODC/OAC DIMENSIONS CIRCUITRY For complete dimensional drawings, see pages H-4 or H-5. LOAD 1 FUSES VAC/VDC G5 Fuses are 5 Amp Littelfuse part number 2 LOAD 217005 or equivalent. +VCC 3 AMP INPUT 4 GROUND 5 Fuse and status LED in G5 modules only. SPECIFICATIONS BY PACKAGE STYLE Package Style Std (70-) Mini (70M-) G5 (70G-) Specifications Units 1 Isolation Voltage Vrms 1500 1500 1500 2 Vibration MIL-STD-202 MIL-STD-202 MIL-STD-202 3 Mechanical Shock MIL-STD-202 MIL-STD-202 MIL-STD-202 Storage Temp. Range C -40 to 125 -40 to 125 -40 to 125 Operating Temp. Range C -20 to 85 -20 to 85 -20 to 85 1 Field to logic and channel-to-channel if Grayhill racks are used. 2 2 MIL-STD-202, Method 204, 20 Gs, 10-2000 Hz or IEC68-2-6, 0.15 mm/sec , 10-150 Hz. 3 MIL-STD-202, Method 213, Condition F, 1500 Gs or IEC68-2-27, 11 mS, 15 gs. H-11 Grayhill, Inc. 561 Hillgrove Avenue LaGrange, Illinois 60525-5997 USA Phone: 708-354-1040 Fax: 708-354-2820 I/O Modules Dry Contact and Electromechanical Relay Output Modules SPECIFICATIONS BY PART NUMBER Standard and Miniature Modules Type/Function Grayhill Part Number Miniature, Normally Open 70M-ODC5R 70M-ODC24R Standard, Normally Open 70-ODC5R 70-OAC5RLY 70-ODC24R Specifications Units Maximum Line Voltage Vdc/Vac 100/120 110/250 100/120 Load Voltage Range Vdc/Vac 0-100/0-120 0-110/0-250 0-100/0-120 Maximum Contact Rating W 10 90 10 1 Maximum Switching Current A 0.5 3.0 0.5 1 Maximum Carry Current A 1.0 5.0 1.0 Minimum Life Expectancy 6 6 10 Vdc/10 mA Cycles 200 x 10 200 x 10 3 3 48 Vdc/100 mA Cycles 500 x 10 500 x 10 3 3 120 Vac/80 mA Cycles 500 x 10 500 x 10 6 30 Vdc or 230 Vac/3A Cycles 100 x 10 Maximum Contact Resistance m 250 250 250 Maximum Off-State Leakage mA .002 .002 .002 2 Maximum Turn-On Time mSec 1 11 1 2 Maximum Turn-Off Time mSec 1 11 1 Nominal Logic Voltage (Vcc) Vdc 5 5 24 Logic Voltage Range Vdc 4.8-6.0 4.8-6.0 20-30 Maximum Logic Supply Current Nominal Vcc mA 10 26 16 Nominal Input Resistance (Rx) 500 200 1700 Minimum Drop Out Voltage Vdc 2.5 4.8 23 Maximum Reverse Logic Voltage Vdc -5 -5 -5 G5 Modules Type/Function Grayhill Part Number G5 Fusible, Normally Open 70G-ODC5R 70G-OAC5RLY 70G-ODC24R Specifications Units Maximum Line Voltage Vdc/Vac 100/120 110/250 100/120 Load Voltage Range Vdc/Vac 0-100/0-120 0-110/0-250 0-100/0-120 Maximum Contact Rating W 10 90 10 1 Maximum Switching Current A 0.5 3.0 0.5 1 Maximum Carry Current A 1.0 5.0 1.0 Minimum Life Expectancy 6 6 10 Vdc/10 mA Cycles 200 x 10 200 x 10 3 3 48 Vdc/100 mA Cycles 500 x 10 500 x 10 3 3 120 Vac/80 mA Cycles 500 x 10 500 x 10 6 30 Vdc or 230 Vac/3A Cycles 100 x 10 Maximum Contact Resistance m 250 250 250 2 Maximum Turn-On Time mSec 1 11 1 2 Maximum Turn-Off Time mSec 1 11 1 Max. Off-State Leakage Max. Line mA .002 .002 .002 Nominal Logic Voltage (Vcc) Vdc 5 5 24 Logic Voltage Range Vdc 4.8-6.0 4.8-6.0 18-32 Max. Logic Supply Current Nominal Vcc mA 10 26 23 Nominal Input Resistance (Rx) 500 200 1200 Minimum Drop Out Voltage Vdc 1 1 23 1 Inductive loads require diode suppression or RC network. Available from your local Grayhill Distributors 2 Times include debounce. For prices and discounts, contact a local Sales Office, an authorized local Distributor, or Grayhill. H-12 Grayhill, Inc. 561 Hillgrove Avenue LaGrange, Illinois 60525-5997 USA Phone: 708-354-1040 Fax: 708-354-2820