Waterproof Connectors for Outdoor Use HR41A Series Mated condition diagram Nut-tightening rear mount type (panel thickness=2mm) 2 70.5 Screw-fastening type with flange 70 Features 1. Waterproof connector designed for outdoor use Fig.1 Light-weight and waterproof, these connectors are well suited for outdoor use applications. The highly weather resistant plastic shell material is compliant with UL Certification : UL746C f1 Class. Locking structure (Push-on bayonet) 2. Waterproof structure Supports IP67 and IP68 ratings while in the mated Mating : Push the plug straight on to the receptacle. condition. (Rating explained below*) *IP67 : Submerged in 1m for 30 minutes *IP68 : Submerged in 2m for 14 days 3. Easy-to-operate push-on bayonet lock Push The push-on bayonet lock quickly achieves complete locking in a single action. (Fig.2) Un-mating : Simply twist and remove the plug 4. Easy field assembly User-friendly operations and assembly allow this connector to be wired in the field. 5. Sequential Contact 1. Rotate locking collar 2. Remove rear-ward. Contacts are sequentially arranged to create a in either directionfirst mate-last brea type of condition. Fig.2 6. Designed to accommodate hot swapping Hot swapping condition : This testing method conforms to UL1977 standards. 7. Surge resistant The walled structure isolates each contact and provides enough insulation to protect against 15kV surges caused by lightning. 8. Safety standard certified The HR41A is certified under the UL1977 specifications. In cases where the application will demand a high level of reliability, such as automotive, 1 2017.2 please contact a company representative for further information.HR41A SeriesWaterproof Connectors for Outdoor Use Product Speci cations Current Rating (Note 3) 13A (Ambient Temperature 25C) Operating Temperature Range - 40 to +105C (Note 1) Ratings Voltage Rating AC 1000V, DC 1000V Storage Temperature Range - 10 to +60C Current Rating (Note3) 10A Operating Temperature Range - 40 to +105C (Note1) UL, TV Voltage Rating AC 600V, DC 600V Storage Temperature Range - 10 to +60C Note 1 : Including temperature rise due to current carrying. Items Speci cations Conditions 1. Contact resistance 5m or less Measured at 1A, DC 2. Insulation resistance A minimum of 5,000M Measured at 500V, DC 3. Withstand voltage No ashover or breakdown 2,200V AC for one minute Frequency : 10 to 55 to 10Hz/cycle No electrical interruption of 10s 4. Vibration resistance Half amplitude 0.75mm, 5 minutes/cycle or more 10 cycles each in 3 axis directions 2 No electrical interruption of 10s Acceleration : 490m/s , duration : 11ms, 5. Shock resistance or more 3 times each in 3 axis directions 6. Durability Contact resistance : up to 10m 500 times -40C for 30 minutes At normal temperature for Insulation resistance : 500M or 2 to 3 minutes +105C for 30 minutes At normal 7. Temperature cycle higher temperature for 2 to 3 minutes. Repeated for 5 cycles. Insulation resistance : 50M or higher 8. Moisture resistance Temperature : 40C, relative humidity : 90 to 95%, ( in a high humidity environment) (Steady state) left for 96 hours 500M or higher (in a dry environment) Left submerged in water in mated condition at depth of 9. Water resistance No water intrusion into the connector 2m for 14 days. Depending on the structure and use of the cable, cable clamping force and cable stress, the waterproof performance may differ from what is noted above. Please check the performance before using the connector. HR41A (5 contacts conducting) Basic Curve Derating Curve Derating Curve 30.00 25.00 20.00 15.00 10.00 5.00 0.00 0 20 40 60 80 100 120 Ambient Temperature C Note 2 : The derating curve is derived from the basic curve multiplied by the derating factor of 0.8. Note 3 : The value of rated current varies with the ambient temperature. It is recommended to use the product within the derating curve zone. When using a UL or T V approved product, please use the product within the speci ed range as well as the derating curve aera. Note 4 : The measurement method of the derating curve is shown below. Test specimen : This product, unused prior to testing. 2 Test cable conductor cross sectional area : 16AWG (1.31mm ) Test condition : Power supplied while the specimen is in a stationary state and then measured. Materials / Finish UL standard Component Materials Finish (noncombustible) Insulator Polyamide resin, PBT resin ---------------------- UL94V-0 Contact Copper alloy Partially gold plated ---------------------- O-ring, gasket Silicone rubber ---------------------- ---------------------- 2 Current A