Waterproof Connectors for Outdoor Use HR41 Series Bayonet Lock Mating MarkMating Mark Features 1. Waterproof connector designed for outdoor use Light weight, waterproof connector designed to withstand outdoor environments. The weatherproof plastic shell provides the strength needed to withstand the elements. 2. Waterproof structure Supports IP67 and IP68 ratings while in the mated condition. (Ratings explained below*) *IP67: Submerged in 1m for 30 minutes *IP68: Submerged in 2m for 14 days 3. Bayonet locking system The bayonet system is user-friendly and is simple Fig. 1 enough to facilitate blind mating in dark or low light areas. (Fig.1) Structure allowing GND to make contact first (3 position) 4. Easy field assembly User-friendly operations and assembly allow this Power Power connector to be wired in the field. 5. Compatible with commercial tooling The crimp contact is compatible with commercial crimp tools that meet the JIS C 9711 standard. Ground 6. Sequential Contact (Fig.3) Fig. 2 3 position: 2 step sequence 5 position: 3 step sequence Sequential Contact mating (5 position) 7. Designed to accommodate hot swapping (5 position plug) Hot swapping condition : AC 20A, AC 300V (50 GND swap cycles). This testing method conforms to UL1977 standards. 8. Surge resistant Power The walled structure isolates each contact and provides enough insulation to protect against 15kV surges caused by lightning. Signal 9. Gold plated contact area Gold plating is applied to the interface contact area to increase the reliability of its connection. Receptacle side Plug side Fig. 3 10.Safety standard certified UL certification and TV certification have been achieved. In cases where the application will demand a high level of reliability, such as automotive, 11 2017.2t please contact a company representative for further information. Dec.1.2018 Copyright 2018 HIROSE ELECTRIC CO., LTD. All Rights Reserved.HR41 SeriesWaterproof Connectors for Outdoor Use Product Speci cations Current Rating (Note 3) 24A (Ambient Temperature 25C) Operating Temperature Range - 40 to +105C (Note 1) Ratings Voltage Rating AC 1000V, DC 1000V Storage Temperature Range - 10 to +60C 20A (5 position, incudes 4 position Current Rating (Note 3) Operating Temperature Range -4 0 to +65C (Note 1) excluding ground are use) UL, TV Voltage Rating AC 600V, DC 600V Storage Temperature Range - 10 to +60C Note 1 : Including temperature rise due to current carrying. Items Speci cations Conditions 1. Contact resistance Maximum of 2m Measured at DC 1A 2. Insulation resistance Minimum of 5,000M Measured at DC 500V 3 pos. : Apply AC 4,260V for 1 minute 3. Withstand voltage No ashover or breakdown 5 pos. : Apply AC 2,200V for 1 minute 10 cycles in 3 axial directions at a frequency of 10 - 4. Vibration resistance No electrical discontinuity of 10s or more 500 - 10Hz, half amplitude 0.75mm and 11 min/cycle 2 Acceleration 490m/s , duration 11ms, half-sine wave, 5. Shock resistance No electrical discontinuity of 10s or more 3 times each for 3 axial directions 6. Durability Contact resistance: Maximum of 4m 200 mating cycles Insulation resistance: 5 cycles of (-55 for 30min ambient temp for 2 to 3 minutes 7. Temperature cycles Maximum of 5,000M 85 for 30min ambient temp for 2 to 3 minutes) 8. Salt water spray Functionality should not be damaged. Spray 5% concentration salt water for 1,000 hours in mated connector condition. Insulation resistance Minimum of 50M (high humidity) 9. Moisture resistance At temperature 40C, humidity 90 to 95%, for 96 hours Minimum of 500M (dry) Left submerged in water in mated condition at depth of 10. Water resistance No water intrusion into connector inside 2m for 14 days. Depending on the structure and use of the cable, cable clamping force and cable stress, the waterproof performance may differ from what is noted above. Please check the performance before using the connector. HR41 (3 contacts conducting) Basic Curve Derating Curve Derating Curve 50.00 45.00 40.00 35.00 30.00 25.00 20.00 15.00 10.00 5.00 0.00 010 20 30 40 60 70 50 Ambient Temperature C Note 2 : The derating curve is derived from the basic curve multiplied by the derating factor of 0.8. Note 3 : The value of rated current varies with the ambient temperature. It is recommended to use the product within the derating curve zone. When using a UL or T V approved product, please use the product within the speci ed range as well as the derating curve aera. Note 4 : The measurement method of the derating curve is shown below. Test specimen : This product, unused prior to testing. 2 Test cable conductor cross sectional area : 5.5mm Test condition : Power supplied while the specimen is in a stationary state and then measured. Materials / Finish Component Materials Finish UL standard (noncombustible) Insulator Polyamide resin, PBT resin ---------------------- UL94V-0 ---------------------- Contact Copper alloy Partially gold plated ---------------------- ---------------------- O-ring, gasket Silicon rubber 2 Dec.1.2018 Copyright 2018 HIROSE ELECTRIC CO., LTD. All Rights Reserved. Current A