ROL R R PD PD R GND R IS PROFET+ 24V BTT6030-2EKB Smart High-Side Power Switch Dual Channel, 32 m Package PG-DSO-14-40 EP Marking BTT6030-2EKB 1 Overview Application Suitable for resistive, inductive and capacitive loads Replaces electromechanical relays, fuses and discrete circuits Most suitable for loads with high inrush current, such as lamps Suitable for 24 V trucks + trailer and transportation systems V BAT Voltage Regulator T1 OUT VS GND Z C VS V VS DD R I/O DEN DEN OUT0 C OUT OUT3 I/O R DSEL DSEL OUT4 I/O R IN0 IN Micro controller I/O R IN1 Bulb IN OUT1 COUT Bulb A/D RSENSE IS GND GND CSENSE D Application Diagram with BTT6030-2EKB Data Sheet Rev. 1.0 www.infineon.com 2016-08-01 PROFET+ 24V BTT6030-2EKB Overview Basic Features Two channel device Very low stand-by current 3.3 V and 5 V compatible logic inputs Electrostatic discharge protection (ESD) Optimized electromagnetic compatibility Logic ground independent from load ground Very low power DMOS leakage current in OFF state Green product (RoHS compliant) AEC qualified Description The BTT6030-2EKB is a 32 m dual channel Smart High-Side Power Switch, embedded in a PG-DSO-14-40 EP, Exposed Pad package, providing protective functions and diagnosis. The power transistor is built by an N-channel vertical power MOSFET with charge pump. The device is integrated in Smart6 HV technology. It is specially designed to drive lamps up to 2 * P21W 24V, as well as LEDs in the harsh automotive environment. Table1 Product Summary Parameter Symbol Value Operating voltage range V 5 V ... 36 V S(OP) Maximum supply voltage V 65 V S(LD) Maximum ON state resistance at T = 150 C per channel R 62 m J DS(ON) Nominal load current (one channel active) I 6A L(NOM)1 Nominal load current (both channels active) I 4A L(NOM)2 Typical current sense ratio k 2240 ILIS Minimum current limitation I 40 A L5(SC) Maximum standby current with load at T = 25 C I 500 nA J S(OFF) Diagnostic Functions Proportional load current sense for both channels multiplexed Open load in ON and OFF Short circuit to battery and ground Overtemperature Stable diagnostic signal during short circuit Enhanced k dependency with temperature and load current ILIS Protection Functions Stable behavior during undervoltage Reverse polarity protection with external components Secure load turn-off during logic ground disconnect with external components Overtemperature protection with latch Overvoltage protection with external components Voltage dependent current limitation Enhanced short circuit protection for up to 40 m cables Data Sheet 2 Rev. 1.0 2016-08-01