Technical Information PrimeSTACK 2PS12017E44G35911 Preliminary data Key data 1x 574A rms at 690V rms, forced air (fan not implemented) General information Stacks for various inverter application. Please read carefully the complete document and maintain the proper design environment Topology 1/2 B2I Application / Modulation Inverter / Sine Load type resistive, inductive Cooling forced air (fan not implemented) Implemented sensors current, temperature Semicond. none (Unit 1) DC Link 1.6mF Semicond. IGBT 4x FF300R17KE4 (Unit 2) electrical CMOS Driver signals IGBT 0 .. 15V Standards EN50178, UL94, prepared for UL508C Sales - name 2PS12017E44G35911 Internal ID 35911 Mechanical drawing number 35911 MB Electrical drawing number 2PS-C4-V DC Link Inverter Section ~ ~ ~ ~ Signal Driver conditioning 1 phase & monitor Electrical interface prepared by: OW date of publication: 2016-02-09 approved by: YZ revision: 2.0 1Technical Information PrimeSTACK 2PS12017E44G35911 Preliminary data Notes Overvoltage shutdown must be realized by the customer. Electrical data DC Link min typ max units Voltage V 1100 1200 V DC Unit 2 AC min typ max units Voltage depending on controller V 690 V Unit2 RMS V = 690V , V = 1100V, T = 40C, Unit2 RMS DC inlet Continuous current TJ 125C, fUnit2 = 50Hz, fsw2 = 2000Hz, IUnit2 574 ARMS cos(phi) = 0,85 Continuous current overload Tinlet = 40C, for overload capability 150% for 60s 418 ARMS cap. Short time current Tinlet = 40C, 10s, every 180s, initial load = 510ARMS IUnit2 638 ARMS DC current no rotating field, Tinlet = 40C IUnit2 DC 280,0 Aav Overcurrent shutdown within 15s 2500 Apeak Switching frequency fsw2 7000 Hz V = 690V, V = 1100V, T = 40C, Unit2 DC inlet Power losses T 125C, f = 50Hz, f = 2000Hz, P 2160 W J Unit2 sw2 loss2 cos(phi) = 0,85, IUnit2 = 574ARMS Power factor cos(phi) -1,00 1,00 Unit2 General data min typ max units Power losses Ploss aux 40 W (PCB) power V 2 kV Burst according to IEC61800-3 at named EMC test control V 1 kV Burst interfaces aux (24V) VSurge 1 kV Insulation management is V 690 V Line RMS designed for Insulation test voltage according to EN50178, f = 50Hz, t = 60s V 2,5 kV isol RMS Controller interface data min typ max units Auxiliary voltage Vaux 13 24 30 Vav Auxiliary power requirement V = 24V P 40 W aux av aux Driver and interface board see separate technical information DR240 EiceDRIVER Driver core 2ED300C17-S Digital input level resistor to GND 10,0k, capacitor to GND 1nF Vin 0,0 15,0 V Digital output level open collector, low = ok, max 15mA Vout 0,0 30,0 V Analog current outputs Unit 2 load max 1mA at 574A Vana out 3,10 3,16 3,22 V Analog temperature output load max 1mA at TNTC = 76C correspond to Tj = 125C VT out 8,69 8,87 9,05 V Overtemperature shutdown at T = 81C correspond to T = 136C V 10 V NTC j T out OT prepared by: OW date of publication: 2016-02-09 approved by: YZ revision: 2.0 2