Technical Information ModSTACK 6MS10017E41W36460 Preliminary data General information IGBT Stack for typical voltages of up to 690 V RMS Rated output current 600 A RMS High power converter Wind power Motor drives TM PrimePACK 3 module with integrated NTC Extended operational temperature Low Vcesat Topology B6I Application Inverter Load type Resistive, inductive Semiconductor (Inverter 3x FF1000R17IE4 Section) DC Link 3.6 mF Heatsink Water cooled Implemented sensors Current, voltage, temperature Driver signals IGBT Electrical Sales - name 6MS10017E41W36460 SP - No. SP000939300 Inverter Section DC Link ~ ~ ~ Signal Driver conditioning 3 phases & monitor Electrical interface prepared by: OW date of publication: 2013-05-10 approved by: AR revision: 2.0 1Technical Information ModSTACK 6MS10017E41W36460 Preliminary data Absolute maximum rated values Collector-emitter voltage IGBT T = 25C V 1700 V vj CES Repetitive peak reverse voltage Diode T = 25C V 1700 V vj RRM DC link voltage V 1250 V DC Insulation management according to installation height of 2000 m V 690 V line RMS Insulation test voltage according to EN 50178, f = 50 Hz, t = 1 s V 2.5 kV ISOL RMS Repetitive peak collector t = 1 ms I 1250 A p CRM2 current inverter section (IGBT) Repetitive peak forward current tp = 1 ms IFRM2 1250 A inverter section (Diode) It-value inverter section It 140 kAs (Diode) Continuous current inverter IAC2 710 ARMS section Junction temperature under switching conditions T 150 C vjop Switching frequency inverter f 5 kHz sw2 section Notes Further maximum ratings are specified in the following dedicated sections Characteristic values DC Link min. typ. max. Rated voltage V 1100 1250 V DC Over voltage shutdown within 150 s 1250 V Capacitor 1 s, 9 p, rated tol. +/- 10 % CDC 3.6 mF type Foil Maximum ripple current per device, Tamb = 55 C Iripple 49 ARMS Balance or discharge resistor per DC link unit Rb 47 k Notes Operation above 1100 V subject to reduced operating time according to EN 61071 Inverter Section min. typ. max. V = 1100 V, V = 690 V , cos() = 0.85, DC AC RMS Rated continuous current IAC 600 ARMS fAC sine = 50 Hz, fsw = 3000 Hz, Tinlet = 40C, Tj 150 C Continuous current at low VDC = 1100 V, VAC = 690 VRMS, fAC sine = 0 Hz, I 295 A AC low RMS frequency f = 3000 Hz, T = 40 C, T 150 C sw inlet j Rated continuous current for I = 610 A , t = 60 s, T 150 C I 405 A AC 150% RMS on over j AC over1 RMS 150% overload capability Rated continuous current for I = 670 A , t = 3 s, T 150 C I 445 A AC 150% RMS on over j AC over2 RMS 150% overload capability Over current shutdown within 15 s I 1250 A AC OC peak I = 600 A, V = 1100 V, V = 690 V , AC DC AC RMS Power losses cos() = 0.85, fAC sine = 50 Hz, fsw = 3000 Hz, Ploss 9800 W T = 40 C, T 150 C inlet j prepared by: OW date of publication: 2013-05-10 approved by: AR revision: 2.0 2