CPC1004N Single-Pole, Normally Open 4-Pin SOP OptoMOS Relay INTEGRATED CIRCUITS DIVISION Description Parameter Rating Units CPC1004N is a miniature, low-voltage, low Blocking Voltage 100 V P on-resistance, normally open (1-Form-A) DC solid Load Current 300 mA DC state relay in a 4-pin SOP package. The relay uses On-Resistance (max) 4 optically coupled MOSFET technology to provide 1500V of input to output isolation. The efficient rms MOSFET switch and photovoltaic die use IXYS Features Integrated Circuits Divisions patented OptoMOS Operating Temperature Range: -40C to +110C architecture while the optically coupled output is 1500V Input/Output Isolation rms controlled by a highly efficient GaAIAs infrared LED. Small 4-Pin SOP Package Low Drive Power Requirements (TTL/CMOS The CPC1004N uses IXYS Integrated Circuits Compatible) Divisions state of the art double-molded vertical No Moving Parts construction packaging to produce one of the worlds High Reliability smallest relays. The CPC1004N is ideal for replacing Arc-Free With No Snubbing Circuits larger, less-reliable reed and electromechanical No EMI/RFI Generation relays. Machine Insertable, Wave Solderable Tape & Reel Version Available Approvals UL Recognized Component: File E76270 Applications CSA Certified Component: Certificate 1175739 Instrumentation EN/IEC 60950-1 Certified Component: Multiplexers TUV Certificate B 09 07 49410 004 Data Acquisition Electronic Switching Ordering Information I/O Subsystems Part Description Meters (Watt-Hour, Water, Gas) CPC1004N 4-Pin SOP (100/tube) Medical EquipmentPatient/Equipment Isolation Security Systems CPC1004NTR 4-Pin SOP (2000/reel) Aerospace Industrial Controls Pin Configuration Reed Relay Replacement 1 4 + Control DC + 2 3 Control DC - Switching Characteristics of Normally Open Devices Form-A I F 90% 10% I LOAD t t on off Pb e3 DS-CPC1004N-R07 1 www.ixysic.comCPC1004N INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 100 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1A Input Power Dissipation 70 mW 1 Total Power Dissipation 400 mW Capacitance Input to Output 1 pF Isolation Voltage, Input to Output 1500 V rms Operational Temperature -40 to +110 C Storage Temperature -40 to +125 C 1 Derate linearly 3.33 mW / C Electrical Characteristics 25C (Unless Otherwise Speci ed) Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current 1 Continuous - - - 300 I L Continuous T=110C, I =10mA - - 100 mA F DC Peak t=10ms I - - 500 LPK 2 On-Resistance I =300mA R -- 4 L ON Off-State Leakage Current V =100V I -- 1 A L P LEAK Switching Speeds Turn-On t -- 3 on I =5mA, V =10V ms F L Turn-Off t -- 1 off Output Capacitance V =50V, f=1MHz C -25 - pF L OUT Input Characteristics Input Control Current to Activate I =300mA I - 0.9 2 mA L F Input Control Current to Deactivate - I 0.3 0.8 - mA F Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I - - 10 A R R 1 o o Load current derates linearly from 300mA 25 C to 100mA 110 C. 2 Measurement taken within 1 second of on-time. R07 2 www.ixysic.com