CPC1016N Single-Pole, Normally Open 4-Lead SOP OptoMOS Relay INTEGRATED CIRCUITS DIVISION Parameter Rating Units Description Blocking Voltage 100 V P CPC1016N is a miniature, low-voltage, low Load Current 100 mA / mA on-resistance, normally open (1-Form-A) solid state rms DC On-Resistance (max) 16 relay in a 4-lead SOP package. The relay uses optically coupled MOSFET technology to provide 1500V of input/output isolation. The efficient rms MOSFET switches and photovoltaic die use IXYS Features Integrated Circuits Divisions patented OptoMOS 1500V Input/Output Isolation rms architecture while the optically coupled output is 100% Solid State controlled by a highly efficient GaAIAs infrared LED. Low Drive Power Requirements (TTL/CMOS Compatible) The CPC1016N uses IXYS Integrated Circuits Arc-Free With No Snubbing Circuits Divisions state of the art double-molded vertical No EMI/RFI Generation construction packaging to produce a very compact Machine Insertable, Wave Solderable solid state relay that is ideal for replacing larger, Tape & Reel Version Available less-reliable reed and electromechanical relays. Approvals Applications UL Recognized Component: File E76270 Instrumentation CSA Certified Component: Certificate 1175739 Multiplexers EN/IEC 60950-1 Certified Component: Data Acquisition TUV Certificate B 09 07 49410 004 Electronic Switching I/O Subsystems Meters (Watt-Hour, Water, Gas) Ordering Information Medical EquipmentPatient/Equipment Part Description Isolation CPC1016N 4-Lead SOP (100/tube) Security Systems CPC1016NTR 4-Lead SOP (2000/reel) Aerospace Industrial Controls Reed Relay Replacement Pin Configuration 1 4 + Control Load 2 3 - Control Load Switching Characteristics of Normally Open Devices Form-A I F 90% 10% I LOAD t t on off Pb e3 DS-CPC1016N-R08 1 www.ixysic.comCPC1016N INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 100 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1A Input Power Dissipation 70 mW 1 Total Power Dissipation 400 mW Isolation Voltage, Input to Output 1500 V rms Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 3.33 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current 1 Continuous -I - - 100 mA / mA L rms DC Peak t=10ms I - - 350 mA LPK P 2 On-Resistance I =100mA R -- 16 L ON Off-State Leakage Current V =100V I -- 1 A L P LEAK Switching Speeds Turn-On t -- 2 ms on I =5mA, V =10V F L Turn-Off t - - 0.5 ms off Output Capacitance V =50V, f=1MHz C -25 - pF L OUT Input Characteristics Input Control Current to Activate I =100mA I - 0.5 2 mA L F Input Control Current to Deactivate - I 0.3 0.4 - mA F Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Capacitance, Input to Output - C -1 - pF I/O 1 Load current derates linearly from 100mA 25C to 80mA 85C. 2 Measurement taken within 1 second of on-time. R08 2 www.ixysic.com