CPC1017N Single-Pole, Normally Open 4-Lead SOP OptoMOS Relay INTEGRATED CIRCUITS DIVISION Parameter Rating Units Description Blocking Voltage 60 V P The CPC1017N is a miniature single pole, normally Load Current 100 mA / mA open (1-Form-A) solid state relay in a 4-lead SOP rms DC On-Resistance (max) 16 package that employs optically coupled MOSFET technology to provide 1500V of input/output LED Current to operate 1 mA rms isolation. The super-efficient MOSFET switches and photovoltaic die use IXYS Integrated Circuits Divisions patented OptoMOS architecture while the Features optically coupled output is controlled by a highly Designed for Use in Security Systems Complying efficient GaAIAs infrared LED. with EN50130-4 IXYS Integrated Circuits Divisions state of the art Only 1mA of LED Current Required to Operate double-molded vertical construction packaging 1500V Input/Output Isolation rms enables CPC1017N to be one of the worlds smallest Small 4-Lead SOP Package relays. It offers board space savings of at least 20% TTL/CMOS Compatible Input over the competitors larger 4-lead SOP relay. No Moving Parts High Reliability Approvals Arc-Free With No Snubbing Circuits No EMI/RFI Generation UL Recognized Component: File E76270 Immune to Radiated EM Fields CSA Certified Component: Certificate 1175739 SMD Pick & Place, Wave Solderable EN/IEC 60950-1 Certified Component: Tape & Reel Version Available TUV Certificate B 09 07 49410 004 Ordering Information Applications Security Part Description Passive Infrared Detectors (PIR) CPC1017N 4-Lead SOP (100/tube) Data Signalling CPC1017NTR 4-Lead SOP (2000/reel) Sensor Circuitry Instrumentation Multiplexers Pin Configuration Data Acquisition 1 4 Electronic Switching + Control Load I/O Subsystems Meters (Watt-Hour, Water, Gas) 2 3 Medical EquipmentPatient/Equipment Isolation Control Load Aerospace Industrial Controls Switching Characteristics of Normally Open Devices Form-A I F 90% 10% I LOAD t t on off Pb e3 DS-CPC1017N-R08 1 www.ixysic.comCPC1017N INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to the Blocking Voltage 60 V P device. Functional operation of the device at conditions beyond Reverse Input Voltage 5 V those indicated in the operational sections of this data sheet is Input Control Current 50 mA not implied. Peak (10ms) 1A Input Power Dissipation 70 mW 1 Total Power Dissipation 400 mW Isolation Voltage, Input to Output 1500 V rms Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 3.33 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current 1 Continuous I =2mA I - - 100 mA / mA F L rms DC Peak t=10ms I - - 350 mA LPK P 2 On-Resistance I =100mA R -- 16 L ON Off-State Leakage Current V =60V I -- 1 A L P LEAK Switching Speeds Turn-On t - - 10 ms on I =5mA, V =10V F L Turn-Off t - - 10 ms off Output Capacitance V =50V, f=1MHz C -25 - pF L OUT Input Characteristics 3 Input Control Current to Activate I =100mA I - 0.4 1 mA L F Input Control Current to Deactivate - I 0.3 - - mA F Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Capacitance, Input to Output - C -1 - pF I/O 1 Load current derates linearly from 100mA 25C to 80mA 80C. 2 Measurement taken within 1 second of on-time. 3 For applications requiring high temperature operation (greater than 60C) a LED drive current of 3mA is recommended. R08 2 www.ixysic.com