CPC1019N 60V, 750mA Single-Pole Normally Open Relay INTEGRATED CIRCUITS DIVISION Parameter Rating Units Description Blocking Voltage 60 V P CPC1019N is a miniature, low-voltage, low Load Current 750 mA on-resistance, single-pole, normally-open (1-Form-A) Load Current, Peak AC 1 A solid state relay in a small 4-pin SOP package. On-Resistance (max) 0.6 Embodying IXYS Integrated Circuits patented LED Current to operate 2 mA OptoMOS technology, the CPC1019N comprises a highly efficient infrared LED that is optically coupled to efficient MOSFET output switches to provide 1500V rms Features of input-to-output isolation. Low On-Resistance: 0.6 IXYS Integrated Circuits state of the art Low Drive Current: 2mA double-molded vertical construction packaging High Load Current: 750mA produces a very compact solid state relay that is 1500V Input/Output Isolation rms ideal for replacing larger, less-reliable reed and Compact 4-Pin SOP Package electromechanical relays. No EMI/RFI Generation Immune to Radiated EM Fields Tape & Reel Version Available Approvals Flammability Rating UL 94 V-0 UL Recognized Component: File E76270 CSA Certified Component: Certificate 1172007 Applications TUV EN 62368-1: Certificate B 082667 0008 Security Passive Infrared Detectors (PIR) Ordering Information Data Signalling Sensor Circuitry Part Description Instrumentation CPC1019N 4-Pin SOP (100/tube) Multiplexers CPC1019NTR 4-Pin SOP (2000/reel) Data Acquisition Electronic Switching I/O Subsystems Pin Configuration Utility Meters (gas, oil, electric and water) 1 4 Medical EquipmentPatient/Equipment Isolation + Control Load Industrial Controls ATE 2 3 - Control Load Switching Characteristics of Normally-Open Devices Form-A I F 90% 10% I LOAD t t on off DS-CPC1019N-R06 1 www.ixysic.comCPC1019N INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to the Blocking Voltage 60 V P device. Functional operation of the device at conditions beyond Reverse Input Voltage 5 V those indicated in the operational sections of this data sheet is Input Control Current 50 mA not implied. Peak (10ms) 1 A 1 Input Power Dissipation 70 mW Typical values are characteristic of the device at +25C, and 2 Total Power Dissipation 400 mW are the result of engineering evaluations. They are provided for Isolation Voltage, Input to Output 1500 V information purposes only, and are not part of the manufacturing rms Operational Temperature, Ambient -40 to +85 C testing requirements. Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate output power linearly 3.33 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Blocking Voltage I =1AV 60 - - V L DRM Load Current Continuous - - 750 mA DC I =2mA I F L Continuous, AC Peak - - 1 A Peak t < 10ms I -- 3 A LPK P 1 On-Resistance I =750mA R - 0.35 0.6 L ON Off-State Leakage Current V =60V I -- 1 A L P LEAK Switching Speeds Turn-On t - 0.4 3 ms on I =5mA, V =10V F L Turn-Off t - 0.4 3 ms off Output Capacitance I =0mA, V =50V, f=1MHz C -60 - pF F L OUT Input Characteristics 2 Input Control Current to Activate I =750mA I - 0.15 2 mA L F Input Control Current to Deactivate - I 0.1 0.14 - mA F Input Voltage Drop I =5mA V 0.9 1.36 1.5 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Capacitance, Input to Output V =0V, f=1MHz C -1 - pF IO IO 1 Measurement taken within 1 second of on-time. 2 o For applications requiring high temperature operation (greater than 60 C) a minimum LED drive current of 4mA is recommended. 2 R06 www.ixysic.com