CPC1025N Single-Pole, Normally Open 4-Lead SOP OptoMOS Relay INTEGRATED CIRCUITS DIVISION Description Parameter Rating Units The CPC1025N is a miniature normally open Blocking Voltage 400 V P (1-Form-A) solid state relay in a 4-lead SOP package Load Current 120 mA / mA rms DC that employs optically coupled MOSFET technol- On-Resistance (max) 30 ogy to provide 1500V of input to output isolation. rms The efficient MOSFET switches and photovoltaic die use IXYS Integrated Circuits Divisions patented Features OptoMOS architecture while the optically coupled 1500V Input/Output Isolation rms output is controlled by a highly efficient GaAIAs Small 4-Lead SOP Package infrared LED. Low Drive Power Requirements (TTL/CMOS Compatible) The CPC1025N uses IXYS Integrated Circuits No Moving Parts Divisions state of the art double-molded vertical High Reliability construction packaging to produce one of the worlds Arc-Free With No Snubbing Circuits smallest relays. It offers board space savings of at No EMI/RFI Generation least 20% over the competitors larger 4-lead SOP Machine Insertable, Wave Solderable relay. Tape & Reel Version Available Approvals UL Recognized Component: File E76270 CSA Certified Component: Certificate 1175739 Applications EN/IEC 60950-1 Certified Component: Telecommunications TUV Certificate B 09 07 49410 004 Telecom Switching Tip/Ring Circuits Modem Switching (Laptop, Notebook, Pocket Ordering Information Size) Part Description Hook Switch CPC1025N 4-Lead SOP (100/tube) Dial Pulsing CPC1025NTR 4-Lead SOP (2000/reel) Ground Start Ringing Injection Instrumentation Pin Configuration Multiplexers Data Acquisition 1 4 + Control Load Electronic Switching I/O Subsystems Meters (Watt-Hour, Water, Gas) 3 2 Control Load Medical EquipmentPatient/Equipment Isolation Security Aerospace Industrial Controls Switching Characteristics of Normally Open Devices Form-A I F 90% 10% I LOAD t t on off Pb e3 DS-CPC1025N-R07 1 www.ixysic.comCPC1025N INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 400 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1A Input Power Dissipation 70 mW 1 Total Power Dissipation 400 mW Capacitance, Input to Output 1 pF Isolation Voltage, Input to Output 1500 V rms Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 3.33 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current 1 Continuous -I - - 120 mA / mA L rms DC Peak t=10ms I - - 350 mA LPK P 2 On-Resistance I =5mA, I =120mA R -25 30 F L ON Off-State Leakage Current V =400V I -- 1 A L P LEAK Switching Speeds Turn-On t -- 2 on I =5mA, V =10V ms F L Turn-Off t -- 1 off Output Capacitance V =50V, f=1MHz C -25 - pF L OUT Input Characteristics 3 Input Control Current to Activate I =120mA I - 0.8 2 mA L F Input Control Current to Deactivate - I 0.3 0.6 - mA F Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I - - 10 A R R 1 o o Load current derates linearly from 120mA 25 C to 80mA 85 C. 2 Measurement taken within 1 second of on-time. 3 For applications requiring high temperature operation (greater than 60C) a LED drive current of 4mA is recomended. R07 2 www.ixysic.com