CPC1215 Voltage-Controlled, Single-Pole, Normally Open OptoMOS Relay INTEGRATED CIRCUITS DIVISION Parameter Rating Units Description Blocking Voltage 400 V The CPC1215 is a voltage-controlled, single-pole, P normally open (1-Form-A), optically coupled solid Load Current 500 mA / mA rms DC state relay in a 4-pin Dual In-line Package (DIP). IXYS On-Resistance (max) 6 Integrated Circuits Division s patented OptoMOS Input Voltage to operate 5-12 V architecture makes available the optically coupled technology necessary to activate the output s efficient MOSFET switches while providing a 3750V input-to- rms Features output isolation barrier. Control of the isolated output is Voltage-Controlled Operation accomplished by means of a highly effective GaAlAs Matches Popular Reed Relay Pin-Out infrared LED at the input while the internal resistor 3750V Input/Output Isolation in series with the LED enables the input s voltage- rms 100% Solid State controlled operation. Arc-Free With No Snubbing Circuits No EMI/RFI Generation Because the input is solid state there is no need for Immune to Radiated EM Fields snubbers orcatc diodes to suppress the inductive 4-Pin DIP Package flyback transient voltage normally associated with EMR Auto Pick & Place, Wave Solderable coils. Approvals Applications UL 1577 Approved Component: Pending Security CSA Certified Component: Certificate 1172007 Passive Infrared Detectors (PIR) Certified to: Data Signalling IEC 60950-1: 2005 Sensor Circuitry EN 60950-1: 2006 Telecommunications TUV Certificate: B 09 07 49410 004 Instrumentation Multiplexers Ordering Information Data Acquisition Electronic Switching Part Description I/O Subsystems CPC1215G 4-Pin DIP (14-Pin Body) (25/tube) Energy Meters Medical EquipmentPatient/Equipment Isolation Pin Configuration Aerospace Industrial Controls 14 8 2 6 + Switching Characteristics of Normally Open Devices Form-A I F 90% 10% I LOAD t t on off Pb e3 DS-CPC1215-R02 1 www.ixysic.comCPC1215 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 400 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Voltage 15 V data sheet is not implied. Input Power Dissipation 225 mW 1 Total Power Dissipation 1600 mW Isolation Voltage, Input to Output 3750 V rms ESD, Human Body Model 8 kV Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 16.6 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current Continuous V =5V I - - 500 mA / mA IN L rms DC Peak t=10ms I - - 1.5 A LPK P 1 On-Resistance I =500mA R - 4.15 6 L ON Off-State Leakage Current V =400V I - 0.009 1 A L P LEAK Switching Speeds Turn-On (Output Closed) t - 1.55 5 on V =5V, V =10V ms IN L Turn-Off (Output Open) t - 0.42 3 off Output Capacitance V =0V, V =50V, f=1MHz C -18 - pF IN L OUT Input Characteristics Input Control Voltage Recommended Operating Range 5- 12 Output Closed I =500mA V - - 3.75 V L IN Output Open 1 - - Reverse Input Current V =-5V I -- 10 A IN R Input Resistor - - 900 1000 1100 Common Characteristics Capacitance, Input to Output - - - 1 - pF 1 Measurement taken within 1 second of on-time. R02 2 www.ixysic.com