CPC1390 Single Pole, Normally Open 4-Pin OptoMOS Relay INTEGRATED CIRCUITS DIVISION Parameter Rating Units Description Peak Blocking Voltage 400 V The CPC1390G is a single-pole normally-open P (1-Form-A) Solid State Relay with an enhanced input Load Current 140 mA / mA rms DC to output isolation barrier of 5000V . On-Resistance (max) 22 rms The relay output is constructed with efficient MOSFET switches that use IXYS Integrated Circuits Division s patented OptoMOS architecture. The input, Features a highly efficient GaAlAS infrared LED, controls the 5000V Input/Output Isolation optically coupled output. rms 400V Blocking Voltage P 100% Solid State Approvals Low Drive Power Requirements (TTL/CMOS UL Certified Component: File E76270 Compatible) CSA Certified Component: Certificate 1172007 Arc-Free With No Snubbing Circuits EN/IEC 60950-1 Certified Component: No EMI/RFI Generation TUV Certificate B 10 05 49410 006 Small 4-Pin Package Machine Insertable, Wave Solderable Ordering Information Part Number Description Applications CPC1390G 4-Pin DIP (100/Tube) Instrumentation CPC1390GV 4-Pin DIP V-Bend (100/Tube) Multiplexers CPC1390GR 4-Pin Surface Mount (100/Tube) Data Acquisition CPC1390GRTR 4-Pin Surface Mount (1000/Reel) Electronic Switching I/O Subsystems Meters (Watt-Hour, Water, Gas) Pin Configuration Medical EquipmentPatient/Equipment Isolation Security 1 4 Aerospace + Control Load Industrial Controls 2 3 Control Load Switching Characteristics of Normally Open Devices Form-A I F 90% 10% I LOAD t t on off Pb e3 DS-CPC1390-R07 1 www.ixysic.comCPC1390 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Peak Blocking Voltage 400 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this data sheet is not implied. Input Control Current 50 mA Peak (10ms) 1 A 1 Input Power Dissipation 100 mW 2 Total Package Dissipation 550 mW Isolation Voltage, Input to Output, 60 sec. 5000 V rms ESD Rating, Human Body Model 8 kV Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 3.00 mW / C Electrical Characteristics 25C Parameters Conditions Symbol Min Typ Max Units Output Characteristics Load Current 1 Continuous -I - - 140 mA / mA L rms DC Peak t=10ms I - - 400 mA LPK P 2 On-Resistance I =2mA, I =140mA R -14 22 F L ON Off-State Leakage Current V =400V I -- 1 A L P LEAK Switching Speeds Turn-On t - 0.525 1 on I =10mA, V =10V ms F L Turn-Off t - 0.42 1 off Output Capacitance I =0mA, V =50V, f=1MHz C -13 - pF F L OUT Input Characteristics 3 Input Control Current to Activate I =140mA I - 0.4 2 mA L F Input Control Current to Deactivate - I 0.2 - - mA F Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Input to Output Capacitance - C -3 - pF I/O 1 Load current derates linearly from 140mA 25C to 70mA 85C. 2 Measurement taken within one second of turn-on time. 3 For applications requiring high-temperature operation (T >60C), a LED current of 4mA is recommended. A R07 2 www.ixysic.com